ISO 9001:2008ISO 9001
Certified
A POWERFUL SOLUTION
All Categories > Control Cables & Portable Power Cables > Control Cables > Type 20/10 Control Cable 600V > 20/10 Control Cable
PE/PVC Insulated Conductors Shielded, PVC Jacket, 600V
> 20/10 Control Cable PE/PVC Insulated Conductors Shielded, PVC Jacket, 600V > View Items
 

20/10 Control Cable PE/PVC Insulated Conductors Shielded, PVC Jacket, 600V

Check up to five results to perform an action.

Applications
Standard general purpose control cable for important control circuits in industrial plants and station control cable for utilities. Suitable for operation and interconnection of protective devices; rated circuit voltage 600 volts, recommended for operation at 75 ºC maximum continuous conductor temperature.
For Non NEC Application Cables may be installed in open air, in ducts or conduit, or in tray or trough and direct burial.

Construction
Stranded uncoated copper conductors, 20 mils black high molecular weight polyethylene insulation, 10 mils full color coded PVC Jacket over each insulated conductor, two conductors flat, three or more conductors twisted with suitable fillers where necessary to make round, polyester tape over assembly, PVC jacket overall, surface printed.

Standards
Physical and electrical tests in accordance with appropriate sections of ICEA S-73-532, NEMA WC57.

Notes
  • Single conductor 20 mils high molecular weight polyethylene insulation and 10 mils polyvinyl chloride jacket, 600 Volt.
  • Color coding is ICEA Appendix E Method 1 Table E-1.
Options
  • Flexible stranded conductors
  • Tin-coated copper conductors per ASTM B33
  • Copper braid shield
  • 1000V rated construction
Consult AWG for a variety of alternate constructions for specific applications.





    Download PDF Download PDF   
    Email Email This Page  
    Save To Favorites Save To Favorites
  
   
  Results 1 - 14 of 14 1 

Item #

Number of
Conductors

Conductor
Size
AWG

Number
of
Strands

Copper
Shield
Thickness
(in)

Copper
Shield
Thickness
(mm)

Nominal
Jacket
Thickness
(in)

Nominal
Jacket
Thickness
(mm)

Nominal
Cable
O.D.
(in)

Nominal
Cable
O.D.
(mm)

Approximate
Cable
Weight
lb/MFT

Approximate
Cable
Weight
kg/km

10-CTB-2-S 2 10 7 0.005 0.1 0.06 1.5 0.6 15.2 233 345
10-CTB-3-S 3 10 7 0.005 0.1 0.06 1.5 0.64 16.3 285 423
10-CTB-4-S 4 10 7 0.005 0.1 0.06 1.5 0.695 17.7 333 493
9-CTB-3-S 3 9 7 0.005 0.1 0.06 1.5 0.62 15.7 258 382
9-CTB-4-S 4 9 7 0.005 0.1 0.06 1.5 0.67 17 318 471
9-CTB-5-S 5 9 7 0.005 0.1 0.06 1.5 0.725 18.4 377 558
8-CTB-3-S 3 8 7 0.005 0.1 0.06 1.5 0.805 20.4 391 579
8-CTB-4-S 4 8 7 0.005 0.1 0.08 2 0.92 23.4 511 756
6-CTB-3-S 3 6 7 0.005 0.1 0.08 2 0.98 24.9 585 866
6-CTB-4-S 4 6 7 0.005 0.1 0.08 2 1.065 27.1 722 1069
4-CTB-3-S 3 4 7 0.005 0.1 0.08 2 1.09 27.7 771 1141
4-CTB-4-S 4 4 7 0.005 0.1 0.08 2 1.19 30.2 982 1453
2-CTB-3-S 3 2 7 0.005 0.1 0.08 2 1.225 31.1 1076 1592
2-CTB-4-S 4 2 7 0.005 0.1 0.08 2 1.345 34.2 1369 2026
  Results 1 - 14 of 14 1 