PowerGuard® 35kV MV Aluminum TR-XLPE Collection System Cable LLDPE Jacket UL MV-90/AEIC CS8-07
>
PowerGuard® 35kV 100% MV Aluminum 345 Mil TR-XLPE Collection System Cable LLDPE Jacket UL MV-90/AEIC CS8-07
>
PowerGuard® 35kV 100% MV 345 Mil TR-XLPE AL Collection System Cable LLDPE Jacket Concentric Neutral UL MV-90/AEIC CS8-07 -
PHYSICAL PROPERTIES (COMPRESSED)
>
View Items
PowerGuard® 35kV 100% MV 345 Mil TR-XLPE AL Collection System Cable LLDPE Jacket Concentric Neutral UL MV-90/AEIC CS8-07 -
PHYSICAL PROPERTIES (COMPRESSED)
Check up to five results to perform an action.
larger image
Applications
PowerGuard® cables are intended for use in wet or dry locations for distribution of single or three phase medium-voltage power. These cables may be installed in ducts or direct buried.
Description
Single conductor cable with filled strand aluminum conductors, triple extruded dry cured insulation system consisting of a thermosetting semiconducting conductor shield, high dielectric strength
PowerGuard®
TRXLPE insulation, thermosetting semiconducting insulation shield, copper concentric neutral wires, water blocking agents, black encapsulating linear low-density polyethylene (LLDPE) jacket.
Designed for 40 years service.
Construction
Conductor:
Class A or B compressed concentric stranded aluminum alloy 1350. Stranded conductors are water-blocked with conductor filling compound.
Conductor Shield:
Extruded thermosetting semiconducting shield which is free stripping from the conductor and bonded to the insulation.
Insulation:
Extruded, Tree-Retardant Cross-linked Polyethylene (TRXLPE) as defined in ANSI/ICEA S-94-649 - 100% insulation level.
Insulation Shield:
Extruded thermosetting semiconducting shield with controlled adhesion to the insulation providing the required balance between electrical integrity and ease of stripping.
Metallic Shield:
Solid bare copper wires helically applied and
uniformly spaced
.
Water Block:
Water-blocking agents applied over the insulation shield and around the neutral wires to resist longitudinal water penetration. Longitudinal water penetration shall be tested in accordance with the latest edition of ICEA T-34-664 except that the minimum requirements are 15 psig for 1 hour.
Jacket:
Black insulating sunlight resistant linear low-density polyethylene encapsulating the neutral wires with three extruded red stripes and NESC lightning bolt symbol.
Insulation Temperature Rating
Normal
90º C
Emergency*
130 ºC
Short Circuit - Shield
200º C
Short Circuit - Conductor
250º C
*Operation at the emergency overload temperature shall not exceed 1500 hours cumulative during the lifetime of the cable.
Specifications
ASTM B-231 (Compact) or ASTM B-400 (Compressed)
AEIC CS8
ICEA S-94-649
ICEA T-31-610
ICEA T-34-664 as applicable for TRXLPE insulated concentric neutral cable
UL 1072 MV-90
CSA Standard C68.5-07 File # 257759 Primary Shielded and Concentric Neutral Cable for Distribution
Options
Copper Conductors
Black LLDPE jacket with no stripes
Multiplex cables
NOTES:
Diameters are based on ASTM Class B Compressed diameters.
Extruded layer thicknesses, insulation and insulation shield diameters are in accordance with ANSI/ICEA S-94-649 for Concentric Neutral Cables Rated 5-46kV and also meet the requirements of the latest revisions of AEIC CS8. Dimensions and weights not designated as minimum or maximum are nominal values and are subject to manufacturing tolerances.
Download PDF
Download PDF
Email This Page
Save To Favorites
Please wait…
Results Per Page :
25
50
100
200
Results 1 - 45 of 45
1
Item #
Cond.
Size
AWG
or
kcmil
Neutral
Size
Neutral
No.
of
Wires
Neutral
Size
of
Wires
Nominal
Diameter
(Inches)
Minimum
Insulation
Diameter
(Inches)
Maximum
Insulation
Diameter
(Inches)
Nominal
Jacket
Diameter
(Inches)
Aluminum
Cond.
Lbs/MFT
Copper
Neutral
Wires
Lbs/MFT
Total
Weight
Lbs/MFT
A1/0-01UD35GT000J
1/0
Full
16
14
0.362
1.045
1.145
1.41
99
209
914
A1/0-01UD35GT200J
1/0
2/3
11
14
0.362
1.045
1.145
1.41
99
144
841
A1/0-01UD35GT001J
1/0
1/2
8
14
0.362
1.045
1.145
1.41
99
104
812
A1/0-01UD35GT100J
1/0
1/3
6
14
0.362
1.045
1.145
1.41
99
78
802
A2/0-01UD35GT100J
2/0
Full
20
14
0.408
1.09
1.19
1.45
125
266
982
A2/0-01UD35GT203J
2/0
2/3
14
14
0.408
1.09
1.19
1.45
125
187
912
A2/0-01UD35GT102J
2/0
1/2
10
14
0.408
1.09
1.19
1.45
125
133
865
A2/0-01UD35GX000J
2/0
1/3
7
14
0.408
1.09
1.19
1.45
125
93
852
A3/0-01UD35GT000J
3/0
Full
16
12
0.458
1.14
1.24
1.56
157
332
1190
A3/0-01UD35GT200J
3/0
2/3
17
14
0.458
1.14
1.24
1.5
157
222
1044
A3/0-01UD35GT300J
3/0
1/2
13
14
0.458
1.14
1.24
1.5
157
170
951
A3/0-01UD35UT103J
3/0
1/3
9
14
0.458
1.14
1.24
1.5
157
118
944
A4/0-01UD35GT000J
4/0
Full
20
12
0.515
1.195
1.295
1.6
198
415
1330
A4/0-01UD35GT200JKT
4/0
2/3
21
14
0.515
1.195
1.295
1.58
198
274
1171
A4/0-01UD35GT050J
4/0
1/2
16
14
0.515
1.195
1.295
1.58
198
209
1126
A4/0-01UD35GT050
4/0
1/3
11
14
0.515
1.195
1.295
1.58
198
144
1074
A4/0-01UD35GT106J
4/0
1/6
6
14
0.515
1.195
1.295
1.58
198
78
1020
A250-01UD35GT100J
250
1/3
13
14
0.561
1.25
1.35
1.62
234
170
1160
A250-01UD35GT106J
250
1/6
10
16
0.561
1.25
1.35
1.6
234
84
1069
A250-01UD35GT112J
250
1/12
6
16
0.561
1.25
1.35
1.6
234
51
1033
A350-01UD35GT101J
350
Full
16
9
0.661
1.355
1.455
1.9
328
667
1993
A350-01UD35GT200J
350
2/3
22
12
0.661
1.355
1.455
1.81
328
458
1695
A350-01UD35GT000J
350
1/2
17
12
0.661
1.355
1.455
1.81
328
354
1603
A350-01UD35GT100J
350
1/3
18
14
0.661
1.355
1.455
1.77
328
235
1457
A350-01UD35GT300J
350
1/6
9
14
0.661
1.355
1.455
1.77
328
117
1358
A350-01UD35GT112J
350
1/12
7
16
0.661
1.355
1.455
1.74
328
59
1256
A500-01UD35GT200J
500
2/3
20
10
0.79
1.48
1.58
1.98
469
662
2181
A500-01UD35GT001J
500
1/2
24
12
0.79
1.48
1.58
1.95
469
498
1983
A500-01UD35GT100J
500
1/3
16
12
0.79
1.48
1.58
1.95
469
332
1854
A500-01UD35GT1314J
500
1/6
13
14
0.79
1.48
1.58
1.92
469
170
1669
A500-01UD35GT112J
500
1/12
10
16
0.79
1.48
1.58
1.89
469
84
1629
A750-01UD35GT001J
750
1/2
23
10
0.968
1.67
1.77
2.2
703
761
2727
A750-01UD35GT100J
750
1/3
24
12
0.968
1.67
1.77
2.16
703
498
2434
A750-01UD35GT300J
750
1/6
19
14
0.968
1.67
1.77
2.14
703
248
2163
A750-01UD35GT400J
750
1/12
10
14
0.968
1.67
1.77
2.14
703
133
2076
A1000-01UD35GT001J
1000
1/2
30
10
1.117
1.815
1.92
2.36
937
993
3311
A1000-01UD35GT000J
1000
1/3
20
10
1.117
1.815
1.92
2.36
937
660
3015
A1000-01UD35GT100J
1000
1/6
16
12
1.117
1.815
1.92
2.32
937
332
2658
A1000-01UD35GT400J
1000
1/12
13
14
1.117
1.815
1.92
2.27
937
173
2455
A1250-01UD35GT100J
1250
1/3
25
10
1.25
1.96
2.065
2.61
1173
827
3755
A1250-01UD35GT000J
1250
1/6
20
12
1.25
1.96
2.065
2.54
1173
415
3225
A1250-01UD35GT400J
1250
1/12
16
14
1.25
1.96
2.065
2.49
1173
209
2984
A1500-01UD35GT100J
1500
1/3
24
9
1.37
2.100
2.205
2.69
1408
1002
4036
A1500-01UD35GT300J
1500
1/6
24
12
1.37
2.100
2.205
2.62
1408
497
3474
A1500-01UD35GT400J
1500
1/12
19
14
1.37
2.100
2.205
2.58
1408
248
3193
Results 1 - 45 of 45
1
Privacy
Site Map
Catalog Index
Site created by
Thomas Web Solutions
and Powered by
Navigator Platform
© 2021, American Wire Group