ISO 9001:2008ISO 9001
Certified
A POWERFUL SOLUTION
All Categories > Medium Voltage Cables > PowerGuard® 35kV MV Aluminum TR-XLPE Collection System Cable XLPE Jacket UL MV-105/AEIC CS8-07 > PowerGuard® 35kV MV TR-XLPE AL Collection System Cable XLPE Jacket UL MV-105/AEIC CS8-07 - PHYSICAL PROPERTIES (COMPACT) > View Items  

PowerGuard® 35kV MV TR-XLPE AL Collection System Cable XLPE Jacket UL MV-105/AEIC CS8-07 - PHYSICAL PROPERTIES (COMPACT)

Check up to five results to perform an action.

Applications
PowerGuard® cables are intended for use in wet or dry locations for distribution of single or three phase medium-voltage power. These cables may be installed in ducts or direct buried.

Description
Single conductor cable with filled strand aluminum conductors, triple extruded dry cured insulation system consisting of a thermosetting semiconducting conductor shield, high dielectric strength PowerGuard® TRXLPE insulation, thermosetting semiconducting insulation shield, copper concentric neutral wires, water blocking agents, black encapsulating cross-linked polyethylene (TRXLPE) jacket.

Construction
Conductor: 
Class A or B compact concentric stranded aluminum alloy 1350 per ASTM B 231. Stranded conductors are water-blocked with conductor filling compound.
Conductor Shield:  Extruded thermosetting semiconducting shield which is free stripping from the conductor and bonded to the insulation.
Insulation: Extruded, Tree-Retardant Cross-linked Polyethylene (TRXLPE) as defined in ANSI/ICEA S-94-649 - 100% insulation level.
Insulation Shield: Extruded thermosetting semiconducting shield with controlled adhesion to the insulation providing the required balance between electrical integrity and ease of stripping.
Metallic Shield: Solid bare copper wires helically applied and uniformly spaced.
Water-blocking agents:  Applied over the insulation shield and around the neutral wires to resist longitudinal water penetration. Longitudinal water penetration shall be tested in accordance with the latest edition of ICEA T-34-664 except that the minimum requirement is 15 psig for 1 hour.
Outer jacket: An extruded-to-fill black non-conducting cross-linked polyethylene jacket, meeting the physical requirements the tables below, when tested by the methods specified in ANSI/ICEA S-94-649. The jacket shall be free-stripping and not interfere with contact between the neutral wires and the underlying extruded insulation shield. The jacket is sunlight resistant.  The jacket shall contain a print legend marking, sequential length marking and three longitudinal extruded red stripes.

Designed for 40 years of service.

Options
  • Copper Conductors
  • Black TRXLPE jacket with no stripes
  • Multiplex cables

Physical Properties of Extruded-to-Fill XLPE Jacket
Unaged Tensile Strength, min. (PSI) 1500
Aged* Tensile Strength, min. ret. (%) 70
Unaged Elongated, min. (%) 150
Aged* Elongated, min. ret. (%)  70
Heat Distortion 1 hr at 131 ºC, max. (%)  30
* Aged for 168 hrs at 121 ºC


Insulation Temperature Rating
Normal 105º C
Emergency* 140º C
Short Circuit - Shield 250º C
Short Circuit - Conductor 350º C
*Operation at the emergency overload temperature shall not exceed 1500 hours cumulative during the lifetime of the cable

Standards
  • ASTM B-231 (Compact) or ASTM B-400 (Compressed)
  • AEIC CS8
  • ICEA S-94-649
  • ICEA T-31-610
  • ICEA T-34-664 as applicable for TRXLPE insulated concentric neutral cable
  • UL 1072 MV-105
  • CSA Standard C68.5-07 File # 257759 Primary Shielded and Concentric Neutral Cable for Distribution

NOTES
  1. Extruded layer thicknesses and insulation and insulation shield diameters are in accordance with ANSI/ICEA S-94-649 for concentric neutral cables rated 5-46 kV and also meet the requirements of the latest revisions of AEIC CS8. Dimensions and weights not designated as minimum or maximum are nominal values and are subject to manufacturing tolerances.
  2. Ampacities based on cables operating in a 3-phase installation with one cable per phase, flat spaced and touching, earth rho of 90ºC-cm/ W, earth ambient of 20ºC, neutral wires grounded at both ends, 75% and 100% load factor, conductor temperature of 105ºC, and 36" depth of burial.

 






    Download PDF Download PDF   
    Email Email This Page  
    Save To Favorites Save To Favorites
  
   
  Results 1 - 42 of 42 1 

Item #

Conductor
AL Size
AWG or
kcmil

Neutral
Size

Neutral
# of Wires
(Size of
Wires)

Conductor
Nominal
Diameter
(in)

Insulation
Minimum
Diameter
(in)

Insulation
Maximum
Diameter
(in)

Jacket
Nominal
Diameter
(in)

AL
Weight
lb/MFT

CU
Weight
lb/MFT

Net
Weight
lb/MFT

A1/0-01UD35GT101X 1/0 Full 12 (14) .336 1.020 1.120 1.358 99 153 946
A1/0-01UD35GT203X 1/0 2/3 13 (16) .336 1.020 1.120 1.358 99 104 869
A1/0-01UD35GT102X 1/0 1/2 10 (16) .336 1.020 1.120 1.358 99 80 850
A1/0-01UD35GT103X 1/0 1/3 7 (16) .336 1.020 1.120 1.358 99 56 831
A2/0-01UD35GT101X 2/0 Full 15 (14) .376 1.060 1.160 1.430 125 192 1038
A2/0-01UD35GT203X 2/0 2/3 16 (16) .376 1.060 1.160 1.430 125 129 948
A2/0-01UD35GT102X 2/0 1/2 12 (16) .376 1.060 1.160 1.430 125 96 923
A2/0-01UD35GT103X 2/0 1/3 9 (16) .376 1.060 1.160 1.430 125 72 904
A3/0-01UD35GT101X 3/0 Full 19 (14) .423 1.105 1.205 1.473 157 243 1151
A3/0-01UD35GT203X 3/0 2/3 13 (14) .423 1.105 1.205 1.473 157 166 1090
A3/0-01UD35GT102X 3/0 1/2 15 (16) .423 1.105 1.205 1.473 157 120 1013
A3/0-01UD35GT103X 3/0 1/3 11 (16) .423 1.105 1.205 1.473 157 88 987
A4/0-01UD35GT101X 4/0 Full 23 (14) .475 1.160 1.260 1.528 199 294 1278
A4/0-01UD35GT203X 4/0 2/3 15 (14) .475 1.160 1.260 1.528 199 192 1196
A4/0-01UD35GT102X 4/0 1/2 12 (14) .475 1.160 1.260 1.528 199 153 1166
A4/0-01UD35GT103X 4/0 1/3 8 (14) .475 1.160 1.260 1.528 199 102 1125
A250-01UD35GT203X 250 2/3 19 (14) .520 1.120 1.315 1.610 235 243 1404
A250-01UD35GT102X 250 1/2 14 (14) .520 1.120 1.315 1.610 235 179 1353
A250-01UD35GT103X 250 1/3 10 (14) .520 1.120 1.315 1.610 235 128 1312
A250-01UD35GT106X 250 1/6 8 (16) .520 1.120 1.315 1.610 235 64 1216
A350-01UD35GT203X 350 2/3 16 (12) .616 1.310 1.410 1.764 329 325 1718
A350-01UD35GT102X 350 1/2 20 (14) .616 1.310 1.410 1.764 329 256 1602
A350-01UD35GT103X 350 1/3 13 (14) .616 1.310 1.410 1.764 329 166 1530
A350-01UD35GT106X 350 1/6 11 (16) .616 1.310 1.410 1.764 329 88 1420
A500-01UD35GT203X 500 2/3 23 (12) .736 1.430 1.530 1.894 469 467 2083
A500-01UD35GT102X 500 1/2 18 (12) .736 1.430 1.530 1.894 469 366 2001
A500-01UD35GT103X 500 1/3 12 (12) .736 1.430 1.530 1.894 469 244 1904
A500-01UD35GT106X 500 1/6 10 (14) .736 1.430 1.530 1.894 469 128 1746
A750-01UD35GT102X 750 1/2 17 (10) .908 1.610 1.710 2.070 704 549 2709
A750-01UD35GT103X 750 1/3 18 (12) .908 1.610 1.710 2.070 704 366 2468
A750-01UD35GT106X 750 1/6 14 (14) .908 1.610 1.710 2.070 704 179 2246
A750-01UD35GT112X 750 1/12 15 (16) .908 1.610 1.710 2.070 704 120 2142
A1000-01UD35GT102X 1000 1/2 22 (10) 1.060 1.760 1.865 2.202 939 711 3226
A1000-01UD35GT103X 1000 1/3 23 (12) 1.060 1.760 1.865 2.202 939 467 2931
A1000-01UD35GT106X 1000 1/6 12 (12) 1.060 1.760 1.865 2.202 939 244 2752
A1000-01UD35GT112X 1000 1/12 10 (14) 1.060 1.760 1.865 2.202 939 128 2581
A1250-01UD35GT103X 1250 1/3 18 (10) 1.250 1.960 2.065 2.450 1173 582 3513
A1250-01UD35GT106X 1250 1/6 15 (12) 1.250 1.960 2.065 2.450 1173 305 3185
A1250-01UD35GT112X 1250 1/12 12 (14) 1.250 1.960 2.065 2.450 1173 153 2952
A1500-01UD35GT103X 1500 1/3 22 (10) 1.370 2.078 2.183 2.606 1408 711 4081
A1500-01UD35GT106X 1500 1/6 18 (12) 1.370 2.078 2.183 2.606 1408 366 3691
A1500-01UD35GT112X 1500 1/12 14 (14) 1.370 2.078 2.183 2.606 1408 179 3454
  Results 1 - 42 of 42 1 