ISO 9001:2008ISO 9001
Certified
A POWERFUL SOLUTION
Applications
This cable is for wiring diesel locomotives, railroad and transit cars, and may be used on electrically driven, earth moving equipment, as power supply to A.C. welding equipment, as water heater leads, and in motor and power lead applications. May be installed in wet or dry areas, conduit, ducts, trays or troughs.

Construction
  • Conductor is extra flexible tinned, stranded copper with a separator layer.
  • EPR insulation.
  • Jacket is CPE (Hypalon jacket available upon request).
Standards
  • Meets flame test requirements of MSHA and passes ICEA cold bend test at -40 ºC.
  • Meets AAR specifications.
  • UL listed as RHH-RHW-2.
  • Rated for CT use, 1/0 and larger.
Notes
  • Ampacity based on single conductor in free air, 90 ºC conductor temperature, 40 ºC ambient per ICEA S-75-381.
  • Sequential footage marks.
  • Shipping tolerance +/- 10%
1 - 22 of 22 | Results Per Page | View | Unit of Measure
1 

Item #

Area
Circular
(mls)

Size
AWG

Number
of Strands
in Conductor

Insulation
Thickness
(mls)

Jacket
Thickness
(mils)

Overall
Diameter

Net Weight
Per MFT

Ampacity
1/C
in Free Air
90 ºC

DL-600/2-1 N/A 3831 N/A 14 N/A 19 N/A 45 N/A 30 N/A .24 Inches N/A 34 Lbs N/A 32
DL-600/2-2 N/A 6088 N/A 12 N/A 19 N/A 45 N/A 30 N/A .25 Inches N/A 45 Lbs N/A 36
DL-600/2-3 N/A 10910 N/A 10 N/A 27 N/A 45 N/A 30 N/A .29 Inches N/A 68 Lbs N/A 55
DL-600/2-4 N/A 14950 N/A 8 N/A 37 N/A 60 N/A 30 N/A .33 Inches N/A 82 Lbs N/A 83
DL-600/2-5 N/A 24640 N/A 6 N/A 61 N/A 60 N/A 30 N/A .40 Inches N/A 125 Lbs N/A 109
DL-600/2-6 N/A 36760 N/A 5 N/A 91 N/A 60 N/A 30 N/A .43 Inches N/A 175 Lbs N/A 127
DL-600/2-7 N/A 42420 N/A 4 N/A 105 N/A 60 N/A 30 N/A .45 Inches N/A 195 Lbs N/A 145
DL-600/2-8 N/A 60600 N/A 2 N/A 150 N/A 60 N/A 30 N/A .50 Inches N/A 265 Lbs N/A 192
DL-600/2-9 N/A 90900 N/A 1 N/A 225 N/A 80 N/A 45 N/A .64 Inches N/A 425 Lbs N/A 223
DL-600/2-10 N/A 111100 N/A 1/0 N/A 275 N/A 80 N/A 45 N/A .69 Inches N/A 500 Lbs N/A 258
DL-600/2-11 N/A 131300 N/A 2/0 N/A 325 N/A 80 N/A 45 N/A .73 Inches N/A 570 Lbs N/A 298
DL-600/2-12 N/A 181800 N/A 3/0 N/A 450 N/A 80 N/A 45 N/A .80 Inches N/A 780 Lbs N/A 345
DL-600/2-13 N/A 222200 N/A 4/0 N/A 550 N/A 80 N/A 45 N/A .86 Inches N/A 890 Lbs N/A 400
DL-600/2-14 N/A 262600 N/A 262.6 N/A 650 N/A 90 N/A 65 N/A .97 Inches N/A 1100 Lbs N/A 458
DL-600/2-15 N/A 313100 N/A 313.1 N/A 775 N/A 90 N/A 65 N/A 1.01 Inches N/A 1280 Lbs N/A 514
DL-600/2-16 N/A 373700 N/A 373.7 N/A 925 N/A 90 N/A 65 N/A 1.11 Inches N/A 1500 Lbs N/A 574
DL-600/2-17 N/A 444400 N/A 444.4 N/A 1100 N/A 90 N/A 65 N/A 1.18 Inches N/A 1760 Lbs N/A 642
DL-600/2-18 N/A 535300 N/A 535.3 N/A 1325 N/A 110 N/A 65 N/A 1.29 Inches N/A 2110 Lbs N/A 725
DL-600/2-19 N/A 646400 N/A 646.4 N/A 1591 N/A 110 N/A 65 N/A 1.38 Inches N/A 2410 Lbs N/A 815
DL-600/2-20 N/A 777700 N/A 777.7 N/A 1924 N/A 110 N/A 65 N/A 1.47 Inches N/A 2930 Lbs N/A 910
DL-600/2-21 N/A 929200 N/A 929.2 N/A 2299 N/A 110 N/A 65 N/A 1.580 Inches N/A 3450 Lbs N/A 1025
DL-600/2-22 N/A 1111000 N/A 1111.0 N/A 2745 N/A 110 N/A 65 N/A 1.74 Inches N/A 4130 Lbs N/A 1143
1 - 22 of 22 | Results Per Page | View | Unit of Measure
1 
FacebookTweeterLinkedInYouTube
Privacy     Site Map     Catalog IndexSite created by Thomas Web Solutions and Powered by Navigator Platform© 2017, American Wire Group