800.342.7215
sales@buyawg.com
ISO 9001
Certified
Menu
Home
Products
Grounding, Static & Guy Wire
Transmission & Distribution Cables
Multiplex Cables
Low Voltage/PV Cables
Medium Voltage Cables
Armored Cables
Control Cables
OPGW / Fiber Optic Cables
Portable Power Cables
AWG Line Card
Ordering Info
How to Order
Terms & Conditions
Shipping Terms
Credit Application
Credit Card Form
Outlet Store
Reference
About
About AWG
Meet the AWG Team
Quality Process
Emergency Response
Survey
Download Catalogs
Complete Catalog
Utility Linecard
Solar Linecard
TE/Raychem Info
Contact Us
All Categories
>
Medium Voltage Cables
>
15-35kV Primary URD Concentric Neutral AEIC CS8-07
>
25kV Primary URD Concentric Neutral LLDPE Jacket AEIC CS8-07
>
TRXLP 25kV Primary URD Concentric Neutral LLDPE Jacket AEIC CS8-07
>
260 MIL TRXLP 25kV Primary URD Concentric Neutral LLDPE Jacket AEIC CS8-07 One Third Neutral, 100% Insulation Level, Copper Conductor
>
View Items
260 MIL TRXLP 25kV Primary URD Concentric Neutral LLDPE Jacket AEIC CS8-07 One Third Neutral, 100% Insulation Level, Copper Conductor
Check up to five results to perform an action.
larger image
Applications
For use on single phase and three phase primary underground distribution systems operating at 25 kV phase to phase at 100 % insulation level. Suitable for either direct burial or installation in ducts.
Construction
Copper concentrically stranded compressed conductor, triple single head extruded conductor shield, TRXLPE (tree-retardant cross-linked polyethylene insulation and easy strippable insulation shield, all dry nitrogen cured; solid bare copper wires uniformly spaced around the cable as a concentric neutral; LLDPE jacket with extruded longitudinal colored stripes, surface printed.
Standards
AEIC CS8 Specification for Extruded Dielectric Shielded Power Cables Rated 5 through 46 kV
ICEA S-94-649 Standard for Concentric Neutral Cables Rated 5,000 - 46,000 V
ICEA T-31-610 Guide for Conducting a Longitudinal Water Penetration Resistance Tests on Blocked Conductors
ICEA T-34-664 Test Method for Conducting Longitudinal Water Penetration Resistance Tests on Longitudinal Water Blocked Cables
UL-1072 MV90
Options
EPR insulation
Filled strand
Cable core water blocking
Notes
Ampacities are based on the NEC.
Cable Tray: Three single cables, installed in uncovered cable tray in accordance with NEC Section 392.13; operating at 105 ºC conductor, at an ambient temperature of 40 ºC.
Buried Duct: Three cables per duct operating at 105 ºC conductor, 20 ºC ground ambient, earth ρ = 90, 100 % load factor.
Conduit in Air: Three cables per isolated conduit in air at 40 ºC operating at 105 ºC conductor (NEC Table 310.73).
Maximum conductor temperature: 90 ºC normal continuous, 130 ºC overload, 250 ºC short circuit.
Download PDF
Download PDF
Email This Page
Save To Favorites
Please wait…
Results Per Page :
25
50
100
200
Results 1 - 9 of 9
1
Item #
Code Name
Conductor
Size AWG
Conductor
Stranding
Copper
Neutral
No. of
Wires
Copper
Neutral
Size
AWG
Conductor
Diameter
Diameter
Over
Insulation
Diameter
Over
Insulation
Shield
Diameter
Over
Neutral
Wires
Diameter
Over
Embedded
Jacket
Total w/o Jacket Weight
Total w/ Embedded Jacket Weight
Ampacity
3/C
Direct Buried
Ampacity
3/C
Triplex Buried
Ampacity
3/C
Duct In Air
260-TRXLP-23
N/A
1/0
19
9
14
0.352
Inches
0.940
Inches
1.022
Inches
1.150
Inches
1.250
Inches
826
Lbs
912
Lbs
275
Amps
215
Amps
189
Amps
260-TRXLP-24
N/A
2/0
19
11
14
0.405
Inches
0.985
Inches
1.065
Inches
1.193
Inches
1.293
Inches
960
Lbs
1048
Lbs
310
Amps
250
Amps
220
Amps
260-TRXLP-25
N/A
3/0
19
14
14
0.456
Inches
1.035
Inches
1.155
Inches
1.283
Inches
1.383
Inches
1166
Lbs
1261
Lbs
345
Amps
285
Amps
250
Amps
260-TRXLP-26
N/A
4/0
19
11
12
0.512
Inches
1.090
Inches
1.210
Inches
1.371
Inches
1.471
Inches
1414
Lbs
1528
Lbs
385
Amps
320
Amps
280
Amps
260-TRXLP-27
Dufay
250
37
13
12
0.558
Inches
1.160
Inches
1.280
Inches
1.442
Inches
1.602
Inches
1628
Lbs
1780
Lbs
410
Amps
345
Amps
303
Amps
260-TRXLP-28
Schuetz
350
37
12
10
0.660
Inches
1.260
Inches
1.380
Inches
1.584
Inches
1.744
Inches
2083
Lbs
2266
Lbs
460
Amps
405
Amps
355
Amps
260-TRXLP-29
Lully
500
37
17
10
0.789
Inches
1.390
Inches
1.510
Inches
1.714
Inches
1.874
Inches
2858
Lbs
3050
Lbs
520
Amps
470
Amps
412
Amps
260-TRXLP-30
N/A
750
61
25
10
0.968
Inches
1.580
Inches
1.741
Inches
1.944
Inches
2.104
Inches
4071
Lbs
4280
Lbs
567
Amps
450
Amps
483
Amps
260-TRXLP-31
N/A
1000
61
33
10
1.117
Inches
1.725
Inches
1.885
Inches
2.089
Inches
2.249
Inches
5190
Lbs
5404
Lbs
625
Amps
615
Amps
540
Amps
Results 1 - 9 of 9