ISO 9001:2008ISO 9001
Certified
A POWERFUL SOLUTION
All Categories > Medium Voltage Cables > 15-35kV Primary URD Concentric Neutral AEIC CS8-07 > 25kV Primary URD Concentric Neutral LLDPE Jacket AEIC CS8-07 > TRXLP 25kV Primary URD Concentric Neutral LLDPE Jacket AEIC CS8-07 > 260 MIL TRXLP 25kV Primary URD Concentric Neutral LLDPE Jacket AEIC CS8-07 One Third Neutral, 100% Insulation Level, Aluminum Conductor > View Items  

260 MIL TRXLP 25kV Primary URD Concentric Neutral LLDPE Jacket AEIC CS8-07 One Third Neutral, 100% Insulation Level, Aluminum Conductor

Check up to five results to perform an action.

Applications
For use on single phase and three phase primary underground distribution systems operating at 25 kV phase to phase at 100 % insulation level. Suitable for either direct burial or installation in ducts.

Construction
Copper concentrically stranded compressed conductor, triple single head extruded conductor shield, TRXLPE (tree-retardant cross-linked polyethylene insulation and easy strippable insulation shield, all dry nitrogen cured; solid bare copper wires uniformly spaced around the cable as a concentric neutral; LLDPE jacket with extruded longitudinal colored stripes, surface printed.

Standards
  • AEIC CS8 Specification for Extruded Dielectric Shielded Power Cables Rated 5 through 46 kV
  • ICEA S-94-649 Standard for Concentric Neutral Cables Rated 5,000 - 46,000 V
  • ICEA T-31-610 Guide for Conducting a Longitudinal Water Penetration Resistance Tests on Blocked Conductors
  • ICEA T-34-664 Test Method for Conducting Longitudinal Water Penetration Resistance Tests on Longitudinal Water Blocked Cables
  • UL-1072 MV90
Options
  • EPR insulation
  • Filled strand
  • Cable core water blocking
Notes
  • Ampacities are based on the NEC.
  • Cable Tray: Three single cables, installed in uncovered cable tray in accordance with NEC Section 392.13; operating at 105 ºC conductor, at an ambient temperature of 40 ºC.
  • Buried Duct: Three cables per duct operating at 105 ºC conductor, 20 ºC ground ambient, earth ρ = 90, 100 % load factor.
  • Conduit in Air: Three cables per isolated conduit in air at 40 ºC operating at 105 ºC conductor (NEC Table 310.73).
  • Maximum conductor temperature: 90 ºC normal continuous, 130 ºC overload, 250 ºC short circuit.





    Download PDF Download PDF   
    Email Email This Page  
    Save To Favorites Save To Favorites
  
   
  Results 1 - 10 of 10 1 

Item #

Code Name

Conductor
Size AWG

Conductor
Stranding

Copper
Neutral
No. of
Wires

Copper
Neutral
Size
AWG

Conductor
Diameter

Diameter
Over
Insulation

Diameter
Over
Insulation
Shield

Diameter
Over
Neutral
Wires

Diameter
Over
Embedded
Jacket

Total w/o Jacket Weight

Total w/ Embedded Jacket Weight

Ampacity
3/C
Direct Buried

Ampacity
3/C
Triplex Buried

Ampacity
3/C
Duct In Air

260-TRXLP-08 N/A 1/0 Solid 6 14 0.325 Inches 0.905 Inches 0.989 Inches 1.117 Inches 1.217 Inches 460 Lbs 631 Lbs 225 Amps 165 Amps 145 Amps
260-TRXLP-09 N/A 1/0 19 6 14 0.362 Inches 0.940 Inches 1.022 Inches 1.150 Inches 1.250 Inches 475 Lbs 650 Lbs 225 Amps 165 Amps 145 Amps
260-TRXLP-10 N/A 2/0 19 7 14 0.405 Inches 0.985 Inches 1.065 Inches 1.193 Inches 1.293 Inches 540 Lbs 715 Lbs 250 Amps 180 Amps 158 Amps
260-TRXLP-11 N/A 3/0 19 9 14 0.456 Inches 1.035 Inches 1.155 Inches 1.283 Inches 1.383 Inches 655 Lbs 842 Lbs 275 Amps 205 Amps 180 Amps
260-TRXLP-12 N/A 4/0 19 11 14 0.512 Inches 1.090 Inches 1.210 Inches 1.338 Inches 1.438 Inches 750 Lbs 966 Lbs 310 Amps 240 Amps 210 Amps
260-TRXLP-13 Wagner 250 37 13 14 0.558 Inches 1.160 Inches 1.280 Inches 1.408 Inches 1.508 Inches 852 Lbs 1117 Lbs 335 Amps 260 Amps 228 Amps
260-TRXLP-14 Gould 350 37 11 12 0.660 Inches 1.260 Inches 1.380 Inches 1.542 Inches 1.702 Inches 1060 Lbs 1380 Lbs 395 Amps 325 Amps 285 Amps
260-TRXLP-15 Schubert 500 37 16 12 0.789 Inches 1.390 Inches 1.510 Inches 1.672 Inches 1.832 Inches 1369 Lbs 1721 Lbs 445 Amps 390 Amps 342 Amps
260-TRXLP-16 Strauss 750 61 15 10 0.968 Inches 1.580 Inches 1.740 Inches 1.944 Inches 2.104 Inches 1920 Lbs 2373 Lbs 515 Amps 475 Amps 417 Amps
260-TRXLP-17 N/A 1000 61 20 10 1.117 Inches 1.725 Inches 1.885 Inches 2.089 Inches 2.249 Inches 2405 Lbs 2870 Lbs 560 Amps 525 Amps 460 Amps
  Results 1 - 10 of 10 1 