800.342.7215
sales@buyawg.com
ISO 9001
Certified
Menu
Home
Products
Grounding, Static & Guy Wire
Transmission & Distribution Cables
Multiplex Cables
Low Voltage/PV Cables
Medium Voltage Cables
Armored Cables
Control Cables
OPGW / Fiber Optic Cables
Portable Power Cables
AWG Line Card
Ordering Info
How to Order
Terms & Conditions
Shipping Terms
Credit Application
Credit Card Form
Outlet Store
Reference
About
About AWG
Meet the AWG Team
Quality Process
Emergency Response
Survey
Download Catalogs
Complete Catalog
Utility Linecard
Solar Linecard
TE/Raychem Info
Contact Us
All Categories
>
Medium Voltage Cables
>
15-35kV Primary URD Concentric Neutral AEIC CS8-07
>
15kV Primary URD Concentric Neutral LLDPE Jacket AEIC CS8-07
>
TRXLP 15kV Primary URD Concentric Neutral LLDPE Jacket AEIC CS8-07
>
175 MIL TRXLP 15kV Primary URD Concentric Neutral LLDPE Jacket AEIC CS8-07 One Third Neutral, Aluminum Conductor
>
View Items
175 MIL TRXLP 15kV Primary URD Concentric Neutral LLDPE Jacket AEIC CS8-07 One Third Neutral, Aluminum Conductor
Check up to five results to perform an action.
larger image
Applications
For use on single phase and three-phase primary underground distribution systems operating at 15kV phase to phase at 100 % insulation level. Suitable for either direct burial or installation in ducts.
Construction
Aluminum concentrically stranded compressed conductor, triple single head extruded conductor shield, TRXLPE (tree-retardant cross-linked polyethylene) insulation and easy strippable insulation shield, all dry nitrogen cured; solid bare copper wires uniformly spaced around the cable as a concentric neutral; LLDPE jacket with extruded longitudinal colored stripes, surface printed.
Standards
AEIC CS8 Specification for Extruded Dielectric Shielded Power Cables Rated 5 through 46kV
ICEA S-94-649 Standard for Concentric Neutral Cables Rated 5,000 - 46,000V
ICEA T-31-610 Guide for Conducting a Longitudinal Water Penetration Resistance Tests on Blocked Conductors
ICEA T-34-664 Test Method for Conducting Longitudinal Water Penetration Resistance Tests on Longitudinal Water Blocked Cables
UL-1072 MV90
Options
EPR insulation
Filled strand
Cable core water blocking
Notes
Ampacities are based on the NEC.
Cable Tray: Three single cables, installed in uncovered cable tray in accordance with NEC Section 392.13; operating at 105 ºC conductor, at an ambient temperature of 40 ºC.
Buried Duct: Three cables per duct operating at 105 ºC conductor, 20 ºC ground ambient, earth ρ = 90, 100 % load factor.
Conduit in Air: Three cables per isolated conduit in air at 40 ºC; operating at 105 ºC conductor (NEC Table 310.73).
Maximum conductor temperature: 90 ºC normal continuous, 130 ºC overload, 250 ºC short circuit.
Download PDF
Download PDF
Email This Page
Save To Favorites
Please wait…
Results Per Page :
25
50
100
200
Results 1 - 10 of 10
1
Item #
Code Name
Conductor
Size AWG
Conductor
Stranding
Copper
Neutral
No. of
Wires
Copper
Neutral
Size
AWG
Ampacity
3/C
Direct Buried
Ampacity
3/C
Triplex Buried
Ampacity
3/C
Duct In Air
175-TRXLP-10
Gable
1/0
Solid
6
14
230
Amps
165
Amps
145
Amps
175-TRXLP-11
N/A
1/0
19
6
14
230
Amps
165
Amps
145
Amps
175-TRXLP-12
N/A
2/0
19
7
14
250
Amps
190
Amps
167
Amps
175-TRXLP-13
N/A
3/0
19
9
14
280
Amps
215
Amps
189
Amps
175-TRXLP-14
N/A
4/0
19
11
14
320
Amps
245
Amps
215
Amps
175-TRXLP-15
Degas
250
37
13
14
345
Amps
270
Amps
237
Amps
175-TRXLP-16
Hals
350
37
11
12
405
Amps
325
Amps
285
Amps
175-TRXLP-17
Bosch
500
37
16
12
460
Amps
385
Amps
338
Amps
175-TRXLP-18
Vernet
750
61
15
10
515
Amps
475
Amps
417
Amps
175-TRXLP-19
N/A
1000
61
20
10
565
Amps
540
Amps
475
Amps
Results 1 - 10 of 10
1
Privacy
Site Map
Catalog Index
Site created by
Thomas Web Solutions
and Powered by
Navigator Platform
© 2021, American Wire Group