ISO 9001:2008ISO 9001
Certified
A POWERFUL SOLUTION
Applications
For use on single phase and three phase primary underground distribution systems operating at 15 kV phase to phase at 100 % insulation level. Suitable for either direct burial or installation in ducts.

Construction
Copper concentrically stranded compressed conductor, triple single head extruded conductor shield, TRXLPE (tree-retardant cross-linked polyethylene) insulation and easy strippable insulation shield, all dry nitrogen cured; solid bare copper wires uniformly spaced around the cable as a concentric neutral; LLDPE jacket with extruded longitudinal colored stripes, surface printed.

Standards
  • AEIC CS8 Specification for Extruded Dielectric Shielded Power Cables Rated 5 through 46 kV
  • ICEA S-94-649 Standard for Concentric Neutral Cables Rated 5,000 - 46,000 V
  • ICEA T-31-610 Guide for Conducting a Longitudinal Water Penetration Resistance Tests on Blocked Conductors
  • ICEA T-34-664 Test Method for Conducting Longitudinal Water Penetration Resistance Tests on Longitudinal Water Blocked Cables
Options
  • EPR insulation
  • Filled strand
  • Cable core water blocking
Notes
  • Ampacities are based on the NEC.
  • Cable Tray: Three single cables, installed in uncovered cable tray in accordance with NEC Section 392.13; operating at 105 ºC conductor, at an ambient temperature of 40 ºC.
  • Buried Duct: Three cables per duct operating at 105 ºC conductor, 20 ºC ground ambient, earth ρ = 90, 100 % load factor.
  • Conduit in Air: Three cables per isolated conduit in air at 40 ºC; operating at 105 ºC conductor (NEC Table 310.73).
  • Maximum conductor temperature: 90 ºC normal continuous, 130 ºC overload, 250 ºC short circuit.
1 - 6 of 6 | Results Per Page | View | Unit of Measure
1 

Item #

Code Name

Conductor
Size AWG

Conductor
Stranding

Copper
Neutral
No. of
Wires

Copper
Neutral
Size
AWG

Conductor
Diameter

Diameter
Over
Insulation

Diameter
Over
Insulation
Shield

Diameter
Over
Neutral
Wires

Diameter
Over
Embedded
Jacket

Total w/o Jacket Weight

Total w/ Embedded Jacket Weight

Ampacity
1/C
Direct
Buried

Ampacity
1/C
Duct
Buried

Ampacity
1/C
Duct In Air

175-TRXLP-20 N/A Titan N/A 2 N/A 7 N/A 16 N/A 14 N/A 0.283 Inches N/A 0.695 Inches N/A 0.775 Inches N/A 0.902 Inches N/A 1.003 Inches N/A 642 Lbs N/A 700 Lbs N/A 225 Amps N/A 160 Amps N/A 140 Amps
175-TRXLP-21 N/A Monet N/A 1 N/A 19 N/A 13 N/A 12 N/A 0.322 Inches N/A 0.730 Inches N/A 0.810 Inches N/A 0.972 Inches N/A 1.072 Inches N/A 504 Lbs N/A 570 Lbs N/A 260 Amps N/A 185 Amps N/A 162 Amps
175-TRXLP-22 N/A Raphael N/A 1/0 N/A 19 N/A 16 N/A 12 N/A 0.362 Inches N/A 0.770 Inches N/A 0.850 Inches N/A 1.012 Inches N/A 1.112 Inches N/A 923 Lbs N/A 993 Lbs N/A 295 Amps N/A 210 Amps N/A 185 Amps
175-TRXLP-23 N/A Rubens N/A 2/0 N/A 19 N/A 20 N/A 12 N/A 0.405 Inches N/A 0.815 Inches N/A 0.895 Inches N/A 1.057 Inches N/A 1.157 Inches N/A 1107 Lbs N/A 1176 Lbs N/A 330 Amps N/A 240 Amps N/A 210 Amps
175-TRXLP-24 N/A Bruegel N/A 3/0 N/A 19 N/A 25 N/A 12 N/A 0.456 Inches N/A 0.865 Inches N/A 0.945 Inches N/A 1.107 Inches N/A 1.207 Inches N/A 1334 Lbs N/A 1402 Lbs N/A 375 Amps N/A 270 Amps N/A 237 Amps
175-TRXLP-25 N/A N/A 4/0 N/A 19 N/A 32 N/A 12 N/A 0.512 Inches N/A 0.920 Inches N/A 1.000 Inches N/A 1.162 Inches N/A 1.262 Inches N/A 1642 Lbs N/A 1708 Lbs N/A 430 Amps N/A 305 Amps N/A 268 Amps
1 - 6 of 6 | Results Per Page | View | Unit of Measure