Medium Voltage Cables
>
15-35kV Primary URD Concentric Neutral AEIC CS8-07
>
15kV Primary URD Concentric Neutral LLDPE Jacket AEIC CS8-07
>
TRXLP 15kV Primary URD Concentric Neutral LLDPE Jacket AEIC CS8-07
>
175 MIL TRXLP 15kV Primary URD Concentric Neutral LLDPE Jacket AEIC CS8-07 Full Neutral, Aluminum Conductor
>
View Items
175 MIL TRXLP 15kV Primary URD Concentric Neutral LLDPE Jacket AEIC CS8-07 Full Neutral, Aluminum Conductor
Check up to five results to perform an action.
larger image
Applications
For use on single phase and three phase primary underground distribution systems operating at 15kV phase to phase at 100 % insulation level. Suitable for either direct burial or installation in ducts.
Construction
Aluminum concentrically stranded compressed conductor, triple single head extruded conductor shield, TRXLPE (tree-retardant cross-linked polyethylene) insulation and easy strippable insulation shield, all dry nitrogen cured; solid bare copper wires uniformly spaced around the cable as a concentric neutral; LLDPE jacket with extruded longitudinal colored stripes, surface printed.
Standards
AEIC CS8 Specification for Extruded Dielectric Shielded Power Cables Rated 5 through 46kV
ICEA S-94-649 Standard for Concentric Neutral Cables Rated 5,000 - 46,000V
ICEA T-31-610 Guide for Conducting a Longitudinal Water Penetration Resistance Tests on Blocked Conductors
ICEA T-34-664 Test Method for Conducting Longitudinal Water Penetration Resistance Tests on Longitudinal Water Blocked Cables
UL-1072 MV90
Options
EPR insulation
Filled strand
Cable core water blocking
Notes
Ampacities are based on the NEC.
Cable Tray: Three single cables, installed in uncovered cable tray in accordance with NEC Section 392.13; operating at 105 ºC conductor, at an ambient temperature of 40 ºC.
Buried Duct: Three cables per duct operating at 105 ºC conductor, 20 ºC ground ambient, earth ρ = 90, 100% load factor.
Conduit in Air: Three cables per isolated conduit in air at 40 ºC; operating at 105 ºC conductor (NEC Table 310.73).
Maximum conductor temperature: 90 ºC normal continuous, 130 ºC overload, 250 ºC short circuit.
Download PDF
Download PDF
Email This Page
Save To Favorites
Please wait…
Results Per Page :
25
50
100
200
Results 1 - 9 of 9
1
Item #
Code Name
Conductor
Size AWG
Conductor
Stranding
Copper
Neutral
No. of
Wires
Copper
Neutral
Size
AWG
Ampacity
1/C
Direct
Buried
Ampacity
1/C
Duct
Buried
Ampacity
1/C
Duct In Air
175-TRXPL-01
Arch
2
Solid
10
14
170
Amps
115
Amps
100
Amps
175-TRXPL-02
Cezanne
2
7
10
14
170
Amps
115
Amps
100
Amps
175-TRXPL-03
Soffit
1
Solid
13
14
195
Amps
140
Amps
123
Amps
175-TRXPL-04
Botticelli
1
19
13
14
195
Amps
140
Amps
123
Amps
175-TRXPL-05
Joists
1/0
Solid
16
14
230
Amps
155
Amps
135
Amps
175-TRXPL-06
Van Gogh
1/0
19
16
14
230
Amps
155
Amps
135
Amps
175-TRXPL-07
Goya
2/0
19
13
12
270
Amps
185
Amps
162
Amps
175-TRXPL-08
El Greco
3/0
19
16
12
295
Amps
210
Amps
184
Amps
175-TRXPL-09
Corot
4/0
19
20
12
335
Amps
240
Amps
210
Amps
Results 1 - 9 of 9