800.342.7215
sales@buyawg.com
ISO 9001
Certified
Menu
Home
Products
Grounding, Static & Guy Wire
Transmission & Distribution Cables
Multiplex Cables
Low Voltage/PV Cables
Medium Voltage Cables
Armored Cables
Control Cables
OPGW / Fiber Optic Cables
Portable Power Cables
AWG Line Card
Ordering Info
How to Order
Terms & Conditions
Shipping Terms
Credit Application
Credit Card Form
Outlet Store
Reference
About
About AWG
Meet the AWG Team
Quality Process
Emergency Response
Survey
Download Catalogs
Complete Catalog
Utility Linecard
Solar Linecard
TE/Raychem Info
Contact Us
All Categories
>
Medium Voltage Cables
>
15-35kV Primary URD Concentric Neutral AEIC CS8-07
>
15kV Primary URD Concentric Neutral LLDPE Jacket AEIC CS8-07
>
TRXLP 15kV Primary URD Concentric Neutral LLDPE Jacket AEIC CS8-07
>
175 MIL TRXLP 15kV Primary URD Concentric Neutral LLDPE Jacket AEIC CS8-07 One Third Neutral, Copper Conductor
>
View Items
175 MIL TRXLP 15kV Primary URD Concentric Neutral LLDPE Jacket AEIC CS8-07 One Third Neutral, Copper Conductor
Check up to five results to perform an action.
larger image
Applications
For use on single phase and three phase primary underground distribution systems operating at 15 kV phase to phase at 100 % insulation level. Suitable for either direct burial or installation in ducts.
Construction
Copper concentrically stranded compressed conductor, triple single head extruded conductor shield, TRXLPE (tree-retardant cross-linked polyethylene) insulation and easy strippable insulation shield, all dry nitrogen cured; solid bare copper wires uniformly spaced around the cable as a concentric neutral; LLDPE jacket with extruded longitudinal colored stripes, surface printed.
Standards
AEIC CS8 Specification for Extruded Dielectric Shielded Power Cables Rated 5 through 46 kV
ICEA S-94-649 Standard for Concentric Neutral Cables Rated 5,000 - 46,000 V
ICEA T-31-610 Guide for Conducting a Longitudinal Water Penetration Resistance Tests on Blocked Conductors
ICEA T-34-664 Test Method for Conducting Longitudinal Water Penetration Resistance Tests on Longitudinal Water Blocked Cables
UL-1072 MV90
Options
EPR insulation
Filled strand
Cable core water blocking
Notes
Ampacities are based on the NEC.
Cable Tray: Three single cables, installed in uncovered cable tray in accordance with NEC Section 392.13; operating at 105 ºC conductor, at an ambient temperature of 40 ºC.
Buried Duct: Three cables per duct operating at 105 ºC conductor, 20 ºC ground ambient, earth ρ = 90, 100% load factor.
Conduit in Air: Three cables per isolated conduit in air at 40 ºC; operating at 105 ºC conductor (NEC Table 310.73).
Maximum conductor temperature: 90 ºC normal continuous, 130 ºC overload, 250 ºC short circuit.
Download PDF
Download PDF
Email This Page
Save To Favorites
Please wait…
Results Per Page :
25
50
100
200
Results 1 - 9 of 9
1
Item #
Code Name
Conductor
Size AWG
Conductor
Stranding
Copper
Neutral
No. of
Wires
Copper
Neutral
Size
AWG
Conductor
Diameter
Diameter
Over
Insulation
Diameter
Over
Insulation
Shield
Diameter
Over
Neutral
Wires
Diameter
Over
Embedded
Jacket
Total w/o Jacket Weight
Total w/ Embedded Jacket Weight
Ampacity
3/C
Direct Buried
Ampacity
3/C
Triplex Buried
Ampacity
3/C
Duct In Air
175-TRXLP-26
N/A
1/0
19
9
14
0.362
Inches
0.770
Inches
0.850
Inches
0.978
Inches
1.078
Inches
708
Lbs
777
Lbs
290
Amps
210
Amps
185
Amps
175-TRXLP-27
N/A
2/0
19
11
14
0.405
Inches
0.815
Inches
0.899
Inches
1.023
Inches
1.123
Inches
836
Lbs
907
Lbs
320
Amps
240
Amps
210
Amps
175-TRXLP-28
N/A
3/0
19
14
14
0.456
Inches
0.865
Inches
0.945
Inches
1.073
Inches
1.173
Inches
1002
Lbs
1074
Lbs
350
Amps
275
Amps
241
Amps
175-TRXLP-29
Holbein
4/0
19
11
12
0.512
Inches
0.920
Inches
1.000
Inches
1.162
Inches
1.262
Inches
1227
Lbs
1317
Lbs
390
Amps
315
Amps
276
Amps
175-TRXLP-30
Moreau
250
37
13
12
0.558
Inches
0.980
Inches
1.060
Inches
1.222
Inches
1.322
Inches
1427
Lbs
1546
Lbs
415
Amps
340
Amps
298
Amps
175-TRXLP-31
McNeil
350
37
12
10
0.660
Inches
1.080
Inches
1.200
Inches
1.404
Inches
1.504
Inches
1904
Lbs
2055
Lbs
475
Amps
415
Amps
364
Amps
175-TRXLP-32
Daumier
500
37
17
10
0.789
Inches
1.210
Inches
1.330
Inches
1.534
Inches
1.694
Inches
2664
Lbs
2823
Lbs
525
Amps
480
Amps
420
Amps
175-TRXLP-33
N/A
750
61
25
10
0.968
Inches
1.400
Inches
1.520
Inches
1.724
Inches
1.884
Inches
3794
Lbs
3964
Lbs
560
Amps
530
Amps
465
Amps
175-TRXLP-34
N/A
1000
61
33
10
1.117
Inches
1.545
Inches
1.705
Inches
1.945
Inches
2.106
Inches
4948
Lbs
5127
Lbs
600
Amps
590
Amps
518
Amps
Results 1 - 9 of 9