Medium Voltage Cables
>
15-35kV Primary URD Concentric Neutral AEIC CS8-07
>
15kV Primary URD Concentric Neutral LLDPE Jacket AEIC CS8-07
>
TRXLP 15kV Primary URD Concentric Neutral LLDPE Jacket AEIC CS8-07
>
220 MIL TRXLP 15kV Primary URD Concentric Neutral LLDPE Jacket AEIC CS8-07 One Third Neutral, Copper Conductor
>
View Items
220 MIL TRXLP 15kV Primary URD Concentric Neutral LLDPE Jacket AEIC CS8-07 One Third Neutral, Copper Conductor
Check up to five results to perform an action.
larger image
Applications
For use on single phase and three phase primary underground distribution systems operating at 15 kV phase to phase at 100 % and 133 % insulation level. Suitable for either direct burial or installation in ducts.
Construction
Copper concentrically stranded compressed conductor, triple single head extruded conductor shield, TRXLPE (tree-retardant cross-linked polyethylene) insulation and easy strippable insulation shield, all dry cured; solid bare copper wires uniformly spaced around the cable as a concentric neutral; LLDPE jacket with extruded longitudinal colored stripes, surface printed.
Standards
AEIC CS8 Specification for Extruded Dielectric Shielded Power Cables Rated 5 through 46 kV
ICEA S-94-649 Standard for Concentric Neutral Cables Rated 5,000 - 46,000V
ICEA T-31-610 Guide for Conducting a Longitudinal Water Penetration Resistance Tests on Blocked Conductors
ICEA T-34-664 Test Method for Conducting Longitudinal Water Penetration Resistance Tests on Longitudinal Water Blocked Cables
UL-1072 MV90
Options
EPR insulation
Filled strand
Cable core water blocking
Notes
Ampacities are based on the NEC.
Cable Tray: Three single cables, installed in uncovered cable tray in accordance with NEC Section 392.13; operating at 105 ºC conductor, at an ambient temperature of 40 ºC.
Buried Duct: Three cables per duct operating at 105 ºC conductor, 20 ºC ground ambient, earth ρ = 90, 100% load factor.
Conduit in Air: Three cables per isolated conduit in air at 40 ºC operating at 105 ºC conductor (NEC Table 310.73).
Maximum conductor temperature: 90 ºC normal continuous, 130 ºC overload, 250 ºC short circuit.
Download PDF
Download PDF
Email This Page
Save To Favorites
Please wait…
Results Per Page :
25
50
100
200
Results 1 - 9 of 9
1
Item #
Conductor
Size AWG
Conductor
Stranding
Copper
Neutral
No. of
Wires
Copper
Neutral
Size
AWG
Ampacity
3/C
Direct Buried
Ampacity
3/C
Triplex Buried
Ampacity
3/C
Duct In Air
220-TRXLP-26
1/0
19
9
14
290
Amps
210
Amps
185
Amps
220-TRXLP-27
2/0
19
11
14
320
Amps
240
Amps
210
Amps
220-TRXLP-28
3/0
19
14
14
350
Amps
275
Amps
241
Amps
220-TRXLP-29
4/0
19
11
12
390
Amps
315
Amps
276
Amps
220-TRXLP-30
250
37
13
12
415
Amps
340
Amps
298
Amps
220-TRXLP-31
350
37
12
10
475
Amps
415
Amps
364
Amps
220-TRXLP-32
500
37
17
10
525
Amps
480
Amps
420
Amps
220-TRXLP-33
750
61
25
10
560
Amps
530
Amps
465
Amps
220-TRXLP-34
1000
61
33
10
600
Amps
590
Amps
518
Amps
Results 1 - 9 of 9