Multiplex Cables (Overhead and Underground)
>
Copper Service Drop Cable 600V
>
Triplex Service Drop Cable
Copper Conductor
>
Copper Triplex Service Drop Cable
>
View Items
Copper Triplex Service Drop Cable
Check up to five results to perform an action.
larger image
Application
Used to supply power, usually from a pole-mounted transformer, to the user's service head where connection to the service entrance cable is made. Also suitable for installations for street lighting, security lights, and temporary service for construction. To be used at voltages of 600 volts phase-to-phase or less and at conductor temperatures not to exceed 75 ºC for polyethylene insulated conductors and 90 ºC for crosslinked polyethylene (XLP) insulated conductors.
Specifications
Meets or exceeds the following ASTM specifications:
B-1 Hard-Drawn Copper Wire.
B-3 Soft or Annealed Copper Wire.
B-8 Concentric-Lay-Stranded Copper Conductors, Hard, Medium-Hard, or Soft.
Meets or exceeds all applicable requirements of ANSI/ICEA S-76-474 for polyethylene and crosslinked polyethylene insulated conductors.
Construction
Conductors are concentrically stranded compressed soft copper insulated with either crosslinked polyethylene, or conventional polyethylene.
Neutral messengers are either solid or concentrically stranded bare hard-drawn copper.
Notes:
Code words for XLP insulated products are formed by adding ""XLP"" to the conventional polyethylene code words above (e.g.- Pica/XLP).
Ampacity figures for black insulation only. Based on conductor temperature of 75 ºC for polyethylene insulated conductors, 90 ºC for XLP insulated conductors, ambient temperature of 40 ºC 2 ft./sec. wind in sun.
Download PDF
Download PDF
Email This Page
Save To Favorites
Please wait…
Results Per Page :
25
50
100
200
Results 1 - 15 of 15
1
Item #
Phase
Conductor
Size
AWG
Phase
Conductor
Stranding
Phase
Conductor
Cover
Thickness
(mils)
Neutral
Messenger
Size
AWG
Neutral
Messenger
Stranding
Neutral
Messenger
Rated
Strength
(lbs.)
Nominal
Lay
Length
(inches)
Weight
per MFT
XLP
Weight
per MFT
Poly
Allowable
Ampacities
XLP
Allowable
Ampacities
Poly
Pica
8
7
45
10
1
529
10.36
160
149
85
70
Columbian
8
1
45
8
1
826
10.36
174
164
85
70
Bodoni
8
7
45
8
1
826
10.36
179
167
85
70
Garamond
8
7
45
8
7
777
10.36
180
169
85
70
Tudor
6
7
45
8
1
826
14.88
246
232
110
90
Futura
6
7
45
6
1
1280
14.88
276
262
110
90
Gothic
6
7
45
6
7
1228
14.88
278
263
110
90
Nonpareil
4
7
45
6
1
1280
14.88
381
363
145
115
Ionic
4
7
45
4
1
1970
14.88
429
411
145
115
Caslon
4
7
45
4
7
1938
14.88
432
413
145
115
Minion
2
7
45
4
1
1970
20.58
594
571
195
155
Primer
2
7
45
4
7
1938
20.58
596
574
195
155
Century
2
7
45
2
7
3050
20.58
674
651
195
155
Corinthian
1/0
19
60
1/0
7
4752
20.58
1073
1036
265
205
Doric
2/0
19
60
2/0
7
5926
25.42
1342
1301
300
235