Copper Conductor
> Copper Triplex Service Drop Cable > View Items
 

Copper Triplex Service Drop Cable

Check up to five results to perform an action.

Application
Used to supply power, usually from a pole-mounted transformer, to the user's service head where connection to the service entrance cable is made. Also suitable for installations for street lighting, security lights, and temporary service for construction. To be used at voltages of 600 volts phase-to-phase or less and at conductor temperatures not to exceed 75 ºC for polyethylene insulated conductors and 90 ºC for crosslinked polyethylene (XLP) insulated conductors.

Specifications
Meets or exceeds the following ASTM specifications:
  • B-1 Hard-Drawn Copper Wire.
  • B-3 Soft or Annealed Copper Wire.
  • B-8 Concentric-Lay-Stranded Copper Conductors, Hard, Medium-Hard, or Soft.
Meets or exceeds all applicable requirements of ANSI/ICEA S-76-474 for polyethylene and crosslinked polyethylene insulated conductors.

Construction
Conductors are concentrically stranded compressed soft copper insulated with either crosslinked polyethylene, or conventional polyethylene.
Neutral messengers are either solid or concentrically stranded bare hard-drawn copper.

Notes:
  • Code words for XLP insulated products are formed by adding ""XLP"" to the conventional polyethylene code words above (e.g.- Pica/XLP).
  • Ampacity figures for black insulation only. Based on conductor temperature of 75 ºC for polyethylene insulated conductors, 90 ºC for XLP insulated conductors, ambient temperature of 40 ºC 2 ft./sec. wind in sun.





    Download PDF Download PDF   
    Email Email This Page  
    Save To Favorites Save To Favorites
  
   
  Results 1 - 15 of 15 1 

Item #

Phase
Conductor
Size
AWG

Phase
Conductor
Stranding

Phase
Conductor
Cover
Thickness
(mils)

Neutral
Messenger
Size
AWG

Neutral
Messenger
Stranding

Neutral
Messenger
Rated
Strength
(lbs.)

Nominal
Lay
Length
(inches)

Weight
per MFT
XLP

Weight
per MFT
Poly

Allowable
Ampacities
XLP

Allowable
Ampacities
Poly

Pica 8 7 45 10 1 529 10.36 160 149 85 70
Columbian 8 1 45 8 1 826 10.36 174 164 85 70
Bodoni 8 7 45 8 1 826 10.36 179 167 85 70
Garamond 8 7 45 8 7 777 10.36 180 169 85 70
Tudor 6 7 45 8 1 826 14.88 246 232 110 90
Futura 6 7 45 6 1 1280 14.88 276 262 110 90
Gothic 6 7 45 6 7 1228 14.88 278 263 110 90
Nonpareil 4 7 45 6 1 1280 14.88 381 363 145 115
Ionic 4 7 45 4 1 1970 14.88 429 411 145 115
Caslon 4 7 45 4 7 1938 14.88 432 413 145 115
Minion 2 7 45 4 1 1970 20.58 594 571 195 155
Primer 2 7 45 4 7 1938 20.58 596 574 195 155
Century 2 7 45 2 7 3050 20.58 674 651 195 155
Corinthian 1/0 19 60 1/0 7 4752 20.58 1073 1036 265 205
Doric 2/0 19 60 2/0 7 5926 25.42 1342 1301 300 235