Item # |
Phase
|
Phase
|
Phase
|
Neutral Size AWG |
Neutral Stranding |
Neutral Insulation Thickness |
Single
|
Outside
|
Weight
|
Ampacity
|
Ampacity
|
---|---|---|---|---|---|---|---|---|---|---|---|
Erskine |
Phase Conductor Size/AWG N/A 6 |
Phase Conductor Stranding N/A 7/w |
Phase Conductor Insulation Thickness N/A 60 mls |
Neutral Size AWG N/A 6 | Neutral Stranding N/A 7/w | Neutral Insulation Thickness N/A 60 mls |
Single Phase Conductor N/A .299 Inches |
Outside Diameter N/A .646 Inches |
Weight Per MFT N/A 143 Lbs |
Ampacity Direct Burial N/A 95 Amps |
Ampacity In Duct N/A 70 Amps |
Vassar |
Phase Conductor Size/AWG N/A 4 |
Phase Conductor Stranding N/A 7/w |
Phase Conductor Insulation Thickness N/A 60 mls |
Neutral Size AWG N/A 4 | Neutral Stranding N/A 7/w | Neutral Insulation Thickness N/A 60 mls |
Single Phase Conductor N/A .345 Inches |
Outside Diameter N/A .754 Inches |
Weight Per MFT N/A 203 Lbs |
Ampacity Direct Burial N/A 125 Amps |
Ampacity In Duct N/A 90 Amps |
Stephens |
Phase Conductor Size/AWG N/A 2 |
Phase Conductor Stranding N/A 7/w |
Phase Conductor Insulation Thickness N/A 60 mls |
Neutral Size AWG N/A 4 | Neutral Stranding N/A 7/w | Neutral Insulation Thickness N/A 60 mls |
Single Phase Conductor N/A .403 Inches |
Outside Diameter N/A .842 Inches |
Weight Per MFT N/A 264 Lbs |
Ampacity Direct Burial N/A 165 Amps |
Ampacity In Duct N/A 120 Amps |
Ramapo |
Phase Conductor Size/AWG N/A 2 |
Phase Conductor Stranding N/A 7/w |
Phase Conductor Insulation Thickness N/A 60 mls |
Neutral Size AWG N/A 2 | Neutral Stranding N/A 7/w | Neutral Insulation Thickness N/A 60 mls |
Single Phase Conductor N/A .403 Inches |
Outside Diameter N/A .874 Inches |
Weight Per MFT N/A 294 Lbs |
Ampacity Direct Burial N/A 165 Amps |
Ampacity In Duct N/A 120 Amps |
Brenau |
Phase Conductor Size/AWG N/A 1/0 |
Phase Conductor Stranding N/A 19/w |
Phase Conductor Insulation Thickness N/A 80 mls |
Neutral Size AWG N/A 2 | Neutral Stranding N/A 7/w | Neutral Insulation Thickness N/A 60 mls |
Single Phase Conductor N/A .522 Inches |
Outside Diameter N/A 1.064 Inches |
Weight Per MFT N/A 408 Lbs |
Ampacity Direct Burial N/A 215 Amps |
Ampacity In Duct N/A 160 Amps |
Bergen |
Phase Conductor Size/AWG N/A 1/0 |
Phase Conductor Stranding N/A 19/w |
Phase Conductor Insulation Thickness N/A 80 mls |
Neutral Size AWG N/A 1/0 | Neutral Stranding N/A 19/w | Neutral Insulation Thickness N/A 80 mls |
Single Phase Conductor N/A .522 Inches |
Outside Diameter N/A 1.133 Inches |
Weight Per MFT N/A 465 Lbs |
Ampacity Direct Burial N/A 215 Amps |
Ampacity In Duct N/A 160 Amps |
Converse |
Phase Conductor Size/AWG N/A 2/0 |
Phase Conductor Stranding N/A 19/w |
Phase Conductor Insulation Thickness N/A 80 mls |
Neutral Size AWG N/A 1 | Neutral Stranding N/A 19/w | Neutral Insulation Thickness N/A 80 mls |
Single Phase Conductor N/A .566 Inches |
Outside Diameter N/A 1.174 Inches |
Weight Per MFT N/A 502 Lbs |
Ampacity Direct Burial N/A 245 Amps |
Ampacity In Duct N/A 160 Amps |
Hunter |
Phase Conductor Size/AWG N/A 2/0 |
Phase Conductor Stranding N/A 19/w |
Phase Conductor Insulation Thickness N/A 80 mls |
Neutral Size AWG N/A 2/0 | Neutral Stranding N/A 19/w | Neutral Insulation Thickness N/A 80 mls |
Single Phase Conductor N/A .566 Inches |
Outside Diameter N/A 1.228 Inches |
Weight Per MFT N/A 560 Lbs |
Ampacity Direct Burial N/A 245 Amps |
Ampacity In Duct N/A 180 Amps |
Hollins |
Phase Conductor Size/AWG N/A 3/0 |
Phase Conductor Stranding N/A 19/w |
Phase Conductor Insulation Thickness N/A 80 mls |
Neutral Size AWG N/A 1/0 | Neutral Stranding N/A 19/w | Neutral Insulation Thickness N/A 80 mls |
Single Phase Conductor N/A .616 Inches |
Outside Diameter N/A 1.276 Inches |
Weight Per MFT N/A 606 Lbs |
Ampacity Direct Burial N/A 280 Amps |
Ampacity In Duct N/A 205 Amps |
Rockland |
Phase Conductor Size/AWG N/A 3/0 |
Phase Conductor Stranding N/A 19/w |
Phase Conductor Insulation Thickness N/A 80 mls |
Neutral Size AWG N/A 3/0 | Neutral Stranding N/A 19/w | Neutral Insulation Thickness N/A 80 mls |
Single Phase Conductor N/A .616 Inches |
Outside Diameter N/A 1.336 Inches |
Weight Per MFT N/A 678 Lbs |
Ampacity Direct Burial N/A 280 Amps |
Ampacity In Duct N/A 205 Amps |
Sweetbriar |
Phase Conductor Size/AWG N/A 4/0 |
Phase Conductor Stranding N/A 19/w |
Phase Conductor Insulation Thickness N/A 80 mls |
Neutral Size AWG N/A 2/0 | Neutral Stranding N/A 19/w | Neutral Insulation Thickness N/A 80 mls |
Single Phase Conductor N/A .672 Inches |
Outside Diameter N/A 1.389 Inches |
Weight Per MFT N/A 739 Lbs |
Ampacity Direct Burial N/A 315 Amps |
Ampacity In Duct N/A 240 Amps |
Monmouth |
Phase Conductor Size/AWG N/A 4/0 |
Phase Conductor Stranding N/A 19/w |
Phase Conductor Insulation Thickness N/A 80 mls |
Neutral Size AWG N/A 4/0 | Neutral Stranding N/A 19/w | Neutral Insulation Thickness N/A 80 mls |
Single Phase Conductor N/A .672 Inches |
Outside Diameter N/A 1.457 Inches |
Weight Per MFT N/A 828 Lbs |
Ampacity Direct Burial N/A 315 Amps |
Ampacity In Duct N/A 240 Amps |
Pratt |
Phase Conductor Size/AWG N/A 250 |
Phase Conductor Stranding N/A 37/w |
Phase Conductor Insulation Thickness N/A 95 mls |
Neutral Size AWG N/A 3/0 | Neutral Stranding N/A 19/w | Neutral Insulation Thickness N/A 80 mls |
Single Phase Conductor N/A .748 Inches |
Outside Diameter N/A 1.538 Inches |
Weight Per MFT N/A 893 Lbs |
Ampacity Direct Burial N/A 345 Amps |
Ampacity In Duct N/A 265 Amps |
Wesleyan |
Phase Conductor Size/AWG N/A 350 |
Phase Conductor Stranding N/A 37/w |
Phase Conductor Insulation Thickness N/A 95 mls |
Neutral Size AWG N/A 4/0 | Neutral Stranding N/A 19/w | Neutral Insulation Thickness N/A 80 mls |
Single Phase Conductor N/A .851 Inches |
Outside Diameter N/A 1.736 Inches |
Weight Per MFT N/A 1166 Lbs |
Ampacity Direct Burial N/A 415 Amps |
Ampacity In Duct N/A 320 Amps |
Holyoke |
Phase Conductor Size/AWG N/A 500 |
Phase Conductor Stranding N/A 37/w |
Phase Conductor Insulation Thickness N/A 95 mls |
Neutral Size AWG N/A 300 | Neutral Stranding N/A 37/w | Neutral Insulation Thickness N/A 95 mls |
Single Phase Conductor N/A .979 Inches |
Outside Diameter N/A 2.008 Inches |
Weight Per MFT N/A 1607 Lbs |
Ampacity Direct Burial N/A 495 Amps |
Ampacity In Duct N/A 395 Amps |
Rider |
Phase Conductor Size/AWG N/A 500 |
Phase Conductor Stranding N/A 37/w |
Phase Conductor Insulation Thickness N/A 95 mls |
Neutral Size AWG N/A 350 | Neutral Stranding N/A 37/w | Neutral Insulation Thickness N/A 95 mls |
Single Phase Conductor N/A .979 Inches |
Outside Diameter N/A 2.035 Inches |
Weight Per MFT N/A 1663 Lbs |
Ampacity Direct Burial N/A 495 Amps |
Ampacity In Duct N/A 395 Amps |
Fairfield |
Phase Conductor Size/AWG N/A 750 |
Phase Conductor Stranding N/A 61/w |
Phase Conductor Insulation Thickness N/A 110 mls |
Neutral Size AWG N/A 500 | Neutral Stranding N/A 37/w | Neutral Insulation Thickness N/A 95 mls |
Single Phase Conductor N/A 1.188 Inches |
Outside Diameter N/A 2.0860 Inches |
Weight Per MFT N/A 2304 Lbs |
Ampacity Direct Burial N/A 615 Amps |
Ampacity In Duct N/A 525 Amps |