Power Cable EPR Insulated Conductors, CPE Jacket, 600V

Check up to five results to perform an action.

Applications
As flame-retardant three or four conductor power cables rated 600 volts, 90 Deg. C. in wet or dry locations. Specifically approved for installation in cable trays per Article 336 of the NEC. Type TC cable is also approved for use in Class I and II, Division 2 hazardous locations. Cables may be installed in open air, in ducts or conduits, in tray or trough, or direct buried.

Construction
Class B stranded tinned annealed copper conductor, Flame-Retardant Ethylene Propylene Rubber (FR-EPR) Type II surface print phase identification. Color-coded per ICEA Method 4; individual conductors colored black with conductor number surface printed in contrasting ink with a Class B stranded uninsulated tinned annealed copper grounding conductor and CPE jacket overall, surface printed.

Standards
  • UL 44 Type XHHW-2
  • UL 1277 Type TC-ER, UL File # E57179
  • UL 1581
  • ICEA S-95-658/NEMA WC70
  • UL 1581 VW-1
  • UL 1277
  • IEEE 383
  • IEEE 1202
  • CSA FT4
  • ICEA T-29-520
Notes
  • Cables may be supplied with an insulated ground and marked ""Open Wiring.""
  • Standard color coding is Method 1 for NEC applications per Appendix E, Table E-2 of ICEA S-73-532(TECH I006). This color coding method omits white and green from the color sequence. A white or green conductor can be supplied on request.
  • Color Coding also available ICEA Method 1, Table E-1; power sizes, ICEA Method 4.
Options
  • Bare or Tinned Copper
  • Flexible stranded conductors
  • E1 or E2 color codes
  • EPR Insulation
  • PVC, CPE, CSPE jackets
  • Overall copper tape shield
  • Overall copper braid shield
  • Overall longitudinal corrugated copper shield
  • Overall Mylar tape shield with drain wire
  • 1000 volt rated construction
Consult AWG for a variety of alternate constructions for specific applications.





    Download PDF Download PDF   
    Email Email This Page  
    Save To Favorites Save To Favorites
  
   
  Results 1 - 29 of 29 1 

Item #

No. of
Conductors

Size
AWG

Conductor
Strand

Ground
Wire
Size
AWG

Nominal
Insulation
Thickness
(in)

Nominal
Insulation
Thickness
(mm)

Nominal
Jacket
Thickness
(in)

Nominal
Jacket
Thickness
(mm)

Nominal
Cable
O.D.
(in)

Nominal
Cable
O.D.
(mm)

Copper
Weight
lbs/MFT

Copper
Weight
kg/km

Net
Weight
lb/MFT

Net
Weight
kg/km

3EEPR-14 3 14 7/.0242 14 0.030 0.76 0.045 1.14 0.430 10.92 55 82 118 176
3EEPR-12 3 12 7/.0305 12 0.030 0.76 0.045 1.14 0.480 12.19 87 129 160 238
3EEPR-10 3 10 7/.0385 10 0.030 0.76 0.06 1.52 0.565 14.35 136 202 237 353
3EEPR-8 3 8 7/.0486 10 0.045 1.14 0.06 1.52 0.655 16.64 190 283 314 467
4EEPR-8 4 8 7/.0486 10 0.045 1.14 0.06 1.52 0.720 18.29 242 360 393 585
3EEPR-6 3 6 7/.0612 8 0.045 1.14 0.06 1.52 0.740 18.80 297 442 456 679
4EEPR-6 4 6 7/.0612 8 0.045 1.14 0.06 1.52 0.790 20.07 384 571 561 835
3EEPR-4 3 4 7/.0772 8 0.045 1.14 0.08 2.03 0.880 22.35 442 658 642 955
4EEPR-4 4 4 7/.0772 8 0.045 1.14 0.08 2.03 0.950 24.13 578 861 822 1223
3EEPR-2 3 2 7/.0974 6 0.045 1.14 0.08 2.03 1.010 25.65 703 1046 979 1457
4EEPR-2 4 2 7/.0974 6 0.045 1.14 0.08 2.03 1.090 27.69 919 1368 1235 1838
3EEPR-1 3 1 19/.0664 6 0.055 1.40 0.08 2.03 1.120 28.45 872 1298 1021 1594
4EEPR-1 4 1 19/.0664 6 0.055 1.40 0.08 2.03 1.235 31.37 1136 1691 1521 2264
3EEPR-1/0 3 1/0 19/.0745 6 0.055 1.40 0.08 2.03 1.225 31.12 1069 1591 1439 2142
4EEPR-1/0 4 1/0 19/.0745 6 0.055 1.40 0.08 2.03 1.330 33.78 1413 2103 1820 2709
3EEPR-2/0 3 2/0 19/.0837 6 0.055 1.40 0.08 2.03 1.300 33.02 1340 1994 1720 2560
4EEPR-2/0 4 2/0 19/.0837 6 0.055 1.40 0.08 2.03 1.440 36.58 1760 2619 2208 3286
3EEPR-3/0 3 3/0 19/.0940 4 0.055 1.40 0.08 2.03 1.420 36.07 1717 2555 2176 3238
4EEPR-3/0 4 3/0 19/.0940 4 0.055 1.40 0.08 2.03 1.570 39.88 2245 3341 2788 3405
3EEPR-4/0 3 4/0 19/.1055 4 0.055 1.40 0.08 2.03 1.540 39.12 2130 3170 2614 3890
4EEPR-4/0 4 4/0 19/.1055 4 0.055 1.40 0.11 2.79 1.790 45.47 2796 4161 3495 5201
3EEPR-250 3 250 37/.0822 4 0.065 1.65 0.11 2.79 1.760 44.70 2494 3712 3184 4738
4EEPR-250 4 250 37/.0822 4 0.065 1.65 0.11 2.79 1.915 48.64 3282 4884 4019 5981
3EEPR-350 3 350 37/.0973 3 0.065 1.65 0.11 2.79 1.960 49.78 3474 5170 4187 6231
4EEPR-350 4 350 37/.0973 3 0.065 1.65 0.11 2.79 2.165 54.99 4577 6811 5436 8090
3EEPR-500 3 500 37/.1162 2 0.065 1.65 0.11 2.79 2.245 57.02 4934 7343 5847 8702
4EEPR-500 4 500 37/.1162 2 0.065 1.65 0.11 2.79 2.475 62.87 6509 9687 7607 11321
3EEPR-750 3 750 61/.1109 1 0.080 2.03 0.14 3.56 2.810 71.37 7278 10831 9145 13610
4EEPR-750 4 750 61/.1109 1 0.080 2.03 0.14 3.56 3.115 79.12 9712 14453 11805 17569