ISO 9001:2008ISO 9001
Certified
A POWERFUL SOLUTION
All Categories > Armored Cables > UL Type MC Copper Conductor with Ground PVC Jacket 600V > UL Type MC Copper Conductor with Ground PVC Jacket 600V > View Items  

UL Type MC Copper Conductor with Ground PVC Jacket 600V

Check up to five results to perform an action.

Applications
MC Cable is approved for use in many applications including direct burial, use in cable tray and outdoor exposure. The PVC jacket is free of harmful heavy metals in compliance with RoHS, Directive 2002/95/EC.

  • Run from the combiner box to the inverter
  • Suitable for rooftop solar applications
  • Outdoors
  • In wet locations (Type XHHW-2, or RHW-2 conductors)
  • Direct buried
  • Encased in concrete
  • Hazardous locations
  • Strong, but lightweight alloy armor resists damage
  • Suitable for wet locations, direct burial, encased in concrete and other uses per the NEC
  • More flexible than conduit
  • Factory tested engineered product that protects conductors from damage during installation
  • Meets or exceeds requirements of the NEC, as well as applicable UL Standards

Construction
Stranded soft drawn copper conductor. Flame retardant thermoset crosslinked polyethylene (XLPE) insulation Type XHHW-2 conductors rated for wet or dry locations at temperatures not to exceed 90ºC. Grounding is one bare copper stranded conductor, except for sizes 14 AWG through 1 AWG contain a green insulated grounding conductor. Phase and grounding conductors are cabled together with binder tape. Aluminum interlocked armor, applied over the binder tape and a longitudinal marker tape, for ID, when unjacketed.  Black sunlight resistant and flame retardant polyvinyl chloride (PVC) compound jacket.  Special constructions available upon request.

Standards

  • Underwriters Laboratories Standards UL-44
  • Class B stranding, per ASTM B 801
  • UL-1569 for Type MC
  • Federal Specification A-A59544
  • IEEE 1202 (70,000 Btu/hr) Vertical Cable Tray Flame Test
  • ICEA T-29-520 (210,000 Btu/hr) Flame Test, and the National Electrical Code (NEC). 
  • Single conductors are rated XHHW-2 600V, and CT Use 1/0 AWG and larger.
  • Additional UL Type PV available upon request.
  • Aluminum armor is rated for Direct Burial, using 6 AWG and larger conductors, with overall jacket

 
NOTES:
Ampacities are based on Table 310.15(B)(16) of the NEC.

*Ampacities shown are for general use as specified by the NEC, Section 310.15. For equipment marked for use at higher temperatures, the conductor ampacity shall be limited to the following per NEC 110.14(C):

60°C when terminated to equipment for circuits rated 100 amperes or less or marked for size 14 AWG through 1 AWG conductor.
75°C when terminated to equipment for circuits rated over 100 amperes or marked for conductors larger than 1 AWG.
90°C for ampacity derating purposes.

When the neutral is considered current-carrying conductor, the ampacity of 4/C cables shall be reduced by a factor of 0.80 per NEC 310.15(B)(2)(a). The above data is approximate and subject to normal manufacturing tolerances.            






    Download PDF Download PDF   
    Email Email This Page  
    Save To Favorites Save To Favorites
  
   
  Results 1 - 45 of 45 1 

Item #

Conductor
Size
(AWG/kcmil)

# of
Conductors

Green
Ground

Outside
Diameter
Over
Armor

Outside
Diameter
Over
Jacket

Jacket
Thickness

Approximate
Net
Weight
(lbs/MFT)

Allowable
Ampacity
75°C
(Amps)

Allowable
Ampacity
90°C
(Amps)

14-02AIAWG 14 2 14 AWG 0.464 0.564 0.05 191 15 15
14-03AIAWG 14 3 14 AWG 0.498 0.700 0.05 219 15 15
14-04AIAWG 14 4 14 AWG 0.536 0.737 0.05 249 15 15
12-02AIAWG 12 2 12 AWG 0.503 0.705 0.05 227 20 20
12-03AIAWG 12 3 12 AWG 0.542 0.747 0.05 265 20 20
12-04AIAWG 12 4 12 AWG 0.584 0.786 0.05 304 20 20
10-02AIAWG 10 2 10 AWG 0.553 0.754 0.05 282 30 30
10-03AIAWG 10 3 10 AWG 0.597 0.799 0.05 335 30 30
10-04AIAWG 10 4 10 AWG 0.646 0.848 0.05 389 30 30
8-02AIAWG 8 2 10 AWG 0.677 0.892 0.05 427 50 55
8-03AIAWG 8 3 10 AWG 0.757 0.957 0.05 524 50 55
8-04AIAWG 8 4 10 AWG 0.834 1.021 0.05 618 50 55
6-02AIAWG 6 2 8 AWG 0.791 0.974 0.05 566 65 75
6-03AIAWG 6 3 8 AWG 0.884 1.045 0.05 700 65 75
6-04AIAWG 6 4 8 AWG 0.974 1.123 0.05 832 65 75
4-03AIAWG 4 3 8 AWG 0.964 1.161 0.05 900 85 95
4-04AIAWG 4 4 8 AWG 1.070 1.250 0.05 1093 85 95
3-03AIAWG 3 3 6 AWG 1.049 1.220 0.05 1075 100 115
3-04AIAWG 3 4 6 AWG 1.164 1.329 0.05 1306 100 115
2-03AIAWG 2 3 6 AWG 1.103 1.306 0.05 1234 115 130
2-04AIAWG 2 4 6 AWG 1.228 1.415 0.05 1515 115 130
1-03AIAWG 1 3 6AWG Green Insulated 1.195 1.295 0.05 1162 130 145
1-04AIAWG 1 4 6AWG Green Insulated 1.336 1.436 0.05 1477 130 145
1/0-03AIAWG 1/0 3 6 AWG Bare 1.213 1.313 0.05 1359 150 170
1/0-04AIAWG 1/0 4 6 AWG Bare 1.335 1.435 0.05 1742 150 170
2/0-03AIAWG 2/0 3 6 AWG Bare 1.308 1.408 0.05 1624 175 195
2/0-04AIAWG 2/0 4 6 AWG Bare 1.441 1.541 0.05 2092 175 195
3/0-03AIAWG 3/0 3 4 AWG Bare 1.415 1.515 0.05 2048 200 225
3/0-04AIAWG 3/0 4 4 AWG Bare 1.562 1.682 0.06 2637 200 225
4/0-03AIAWG 4/0 3 4 AWG Bare 1.536 1.656 0.06 2498 230 260
4/0-04AIAWG 4/0 4 4 AWG Bare 1.697 1.817 0.06 3233 230 260
250-03AIAWG 250 3 4 AWG Bare 1.648 1.768 0.06 2904 255 290
250-04AIAWG 250 4 4 AWG Bare 1.822 1.942 0.06 3770 255 290
300-03AIAWG 300 3 3 AWG Bare 1.760 1.880 0.06 3192 285 320
300-04AIAWG 300 4 3 AWG Bare 1.948 2.068 0.06 4211 285 320
350-03AIAWG 350 3 3 AWG Bare 1.862 1.982 0.06 3931 310 350
350-04AIAWG 350 4 3 AWG Bare 2.061 2.181 0.06 5120 310 350
400-03AIAWG 400 3 3 AWG Bare 1.956 2.076 0.06 4173 335 380
400-04AIAWG 400 4 3 AWG Bare 2.167 2.287 0.06 5514 335 380
500-03AIAWG 500 3 2 AWG Bare 2.131 2.251 0.06 5451 380 430
500-04AIAWG 500 4 2 AWG Bare 2.363 2.513 0.075 7124 380 430
600-03AIAWG 600 3 2 AWG Bare 2.411 2.561 0.075 6454 420 475
600-04AIAWG 600 4 2 AWG Bare 2.677 2.827 0.075 8450 420 475
750-03AIAWG 750 3 1 AWG Bare 2.631 2.781 0.075 8015 475 535
750-04AIAWG 750 4 1 AWG Bare 2.923 3.073 0.075 10506 475 535
  Results 1 - 45 of 45 1 
Privacy     Site Map     Catalog IndexSite created by Thomas Web Solutions and Powered by Navigator Platform© 2021, American Wire Group