Type MC Cable is primarily used for services, feeders, and branch circuits as specified in the 2011 National Electric Code. Type MC cable with Type XHHW-2 conductors may be used in wet or dry locations at temperatures not to exceed 90°C. Used for power and lighting indoors, exposed or concealed, in cable tray where identified for such use; in a raceway, or in dry locations and embedded in plaster or against other masonry. Voltage rating for XHHW-2 conductors is 600V.
Construction
Compact stranded AA-8000 series aluminum conductor material per ASTM B800, ASTM B801, ASTM B836, ASTM B901 (Single Input Wire), as applicable. XLPE insulated XHHW-2 conductors are twisted with a bare conductor. A binder tape is wrapped over the conductors with interlocked aluminum tape applied over the assembly. Rated 90°C wet or dry and is flame and sunlight resistant.
Specifications
Type MC cable with Type XHHW-2 conductors are manufactured and tested in accordance with the latest revisions of:
- UL 44 for Thermoset-Insulated Wires and Cables
- UL 83 for Thermoplastic-Insulated Wires and Cables
- UL 1479 Standard for Fire Tests of Through-Penetration Firestops.
- UL Classified 1, 2, and 3 Hour Through-Penetration Firestop Systems.
- UL 1569 for Metal-Clad Cables.
- IEEE 1202 - Flame Testing of Cables for Use in Cable Tray, in Industrial and Commercial Occupancies (70,000 BTU/hr).
- ICEA T-29-520 - Vertical Cable Tray Flame Tests (210,000 Btu/hr).
- ICEA S-66-524 and requirements of the National Electric Code
- ICEA S-95-658 (NEMA WC 70) construction requirements
- Federal Specification J-C-30B
Color Code
Four Phase Conductors (4): Black, red, blue, white
Grounding Conductor (1): Bare
Other colors and stripes available by special order.
For Special Order
- The entire assembly can be covered with a PVC or CPE outer jacket (black or color). Jacketed MC Cable may be used in wet locations, either direct burial, in underground conduit, or overhead.
- Halogen free jackets are available upon request
- A black jacket (on individual conductors) with color stripes can be requested.
- Bare Ground conductor available upon request.
- For sizes not listed above please contact sales.
Ampacity
To determine correct ampacity by conductor size, please consult the National Electric Code, latest edition.
Item # |
Size
|
Phase
|
Number
|
Diameter
|
Thickness
|
Size
|
Diameter
|
Thickness
|
Cabling
|
Overall
|
AL
|
Cable
|
Conductor
|
Neutral
|
Neutral
|
Neutral
|
Sequence
|
Seq
|
Ampacity
|
Ampacity
|
Conductor
|
Neutral
|
Neutral
|
Conductor
|
Capacitance
|
Short-Circuit Current
|
Short-Circuit Current
|
Short-Circuit Current
|
Short-Circuit Current
|
Short-Circuit Current
|
Short-Circuit Current
|
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
A900-04MC2/0 |
Size of Cable N/A 900-900-900-900+2/0 |
Phase Conductor Size AWG/MCM N/A 900 |
Number of Phase Conductors N/A 4 |
Diameter of Conductor (mils) N/A 1000 |
Thickness of Conductor Insulation (mils) N/A 80 |
Size of Ground Conductor AWG/MCM N/A 2/0 |
Diameter of Ground (mils) N/A 376 |
Thickness of Ground Insulation (mils) N/A 55 |
Cabling Diameter (mils) N/A 2807 |
Overall Diameter of Cable Over Armour (mils) N/A 3131 |
AL Weight (lb/mft) N/A 3977 |
Cable Weight (lb/mft) N/A 3977 |
Conductor Size AWG or kcmil N/A |
Neutral Wires N/A |
Neutral Size AWG N/A |
Neutral Size N/A |
Sequence Impedance Pos/Neg (µΩ/feet) N/A |
Seq Impedance Zero (µΩ/feet) N/A |
Ampacity LF=100% (A) N/A |
Ampacity LF=75% (A) N/A |
Conductor Size (AWG or kcmil) N/A |
Neutral Wires N/A |
Neutral Size (AWG) N/A |
Conductor Resistance @ 20º C (Ω / 1000 ft) N/A |
Capacitance (μF / 1000 ft) N/A |
Short-Circuit Current - Conductor - 8 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 8 Cycles - (A) N/A |
Short-Circuit Current - Conductor - 16 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 16 Cycles - (A) N/A |
Short-Circuit Current - Conductor - 24 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 24 Cycles - (A) N/A |
A900-04MC3/0 |
Size of Cable N/A 900-900-900-900+3/0 |
Phase Conductor Size AWG/MCM N/A 900 |
Number of Phase Conductors N/A 4 |
Diameter of Conductor (mils) N/A 1000 |
Thickness of Conductor Insulation (mils) N/A 80 |
Size of Ground Conductor AWG/MCM N/A 3/0 |
Diameter of Ground (mils) N/A 421 |
Thickness of Ground Insulation (mils) N/A 55 |
Cabling Diameter (mils) N/A 2878 |
Overall Diameter of Cable Over Armour (mils) N/A 3202 |
AL Weight (lb/mft) N/A 4022 |
Cable Weight (lb/mft) N/A 4022 |
Conductor Size AWG or kcmil N/A |
Neutral Wires N/A |
Neutral Size AWG N/A |
Neutral Size N/A |
Sequence Impedance Pos/Neg (µΩ/feet) N/A |
Seq Impedance Zero (µΩ/feet) N/A |
Ampacity LF=100% (A) N/A |
Ampacity LF=75% (A) N/A |
Conductor Size (AWG or kcmil) N/A |
Neutral Wires N/A |
Neutral Size (AWG) N/A |
Conductor Resistance @ 20º C (Ω / 1000 ft) N/A |
Capacitance (μF / 1000 ft) N/A |
Short-Circuit Current - Conductor - 8 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 8 Cycles - (A) N/A |
Short-Circuit Current - Conductor - 16 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 16 Cycles - (A) N/A |
Short-Circuit Current - Conductor - 24 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 24 Cycles - (A) N/A |
A900-04MC4/0 |
Size of Cable N/A 900-900-900-900+4/0 |
Phase Conductor Size AWG/MCM N/A 900 |
Number of Phase Conductors N/A 4 |
Diameter of Conductor (mils) N/A 1000 |
Thickness of Conductor Insulation (mils) N/A 80 |
Size of Ground Conductor AWG/MCM N/A 4/0 |
Diameter of Ground (mils) N/A 476 |
Thickness of Ground Insulation (mils) N/A 55 |
Cabling Diameter (mils) N/A 2902 |
Overall Diameter of Cable Over Armour (mils) N/A 3225 |
AL Weight (lb/mft) N/A 4066 |
Cable Weight (lb/mft) N/A 4066 |
Conductor Size AWG or kcmil N/A |
Neutral Wires N/A |
Neutral Size AWG N/A |
Neutral Size N/A |
Sequence Impedance Pos/Neg (µΩ/feet) N/A |
Seq Impedance Zero (µΩ/feet) N/A |
Ampacity LF=100% (A) N/A |
Ampacity LF=75% (A) N/A |
Conductor Size (AWG or kcmil) N/A |
Neutral Wires N/A |
Neutral Size (AWG) N/A |
Conductor Resistance @ 20º C (Ω / 1000 ft) N/A |
Capacitance (μF / 1000 ft) N/A |
Short-Circuit Current - Conductor - 8 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 8 Cycles - (A) N/A |
Short-Circuit Current - Conductor - 16 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 16 Cycles - (A) N/A |
Short-Circuit Current - Conductor - 24 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 24 Cycles - (A) N/A |
A900-04MC250 |
Size of Cable N/A 900-900-900-900+250 |
Phase Conductor Size AWG/MCM N/A 900 |
Number of Phase Conductors N/A 4 |
Diameter of Conductor (mils) N/A 1000 |
Thickness of Conductor Insulation (mils) N/A 80 |
Size of Ground Conductor AWG/MCM N/A 250 |
Diameter of Ground (mils) N/A 520 |
Thickness of Ground Insulation (mils) N/A 65 |
Cabling Diameter (mils) N/A 2902 |
Overall Diameter of Cable Over Armour (mils) N/A 3225 |
AL Weight (lb/mft) N/A 4103 |
Cable Weight (lb/mft) N/A 4103 |
Conductor Size AWG or kcmil N/A |
Neutral Wires N/A |
Neutral Size AWG N/A |
Neutral Size N/A |
Sequence Impedance Pos/Neg (µΩ/feet) N/A |
Seq Impedance Zero (µΩ/feet) N/A |
Ampacity LF=100% (A) N/A |
Ampacity LF=75% (A) N/A |
Conductor Size (AWG or kcmil) N/A |
Neutral Wires N/A |
Neutral Size (AWG) N/A |
Conductor Resistance @ 20º C (Ω / 1000 ft) N/A |
Capacitance (μF / 1000 ft) N/A |
Short-Circuit Current - Conductor - 8 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 8 Cycles - (A) N/A |
Short-Circuit Current - Conductor - 16 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 16 Cycles - (A) N/A |
Short-Circuit Current - Conductor - 24 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 24 Cycles - (A) N/A |
A900-04MC300 |
Size of Cable N/A 900-900-900-900+300 |
Phase Conductor Size AWG/MCM N/A 900 |
Number of Phase Conductors N/A 4 |
Diameter of Conductor (mils) N/A 1000 |
Thickness of Conductor Insulation (mils) N/A 80 |
Size of Ground Conductor AWG/MCM N/A 300 |
Diameter of Ground (mils) N/A 571 |
Thickness of Ground Insulation (mils) N/A 65 |
Cabling Diameter (mils) N/A 2957 |
Overall Diameter of Cable Over Armour (mils) N/A 3280 |
AL Weight (lb/mft) N/A 4158 |
Cable Weight (lb/mft) N/A 4158 |
Conductor Size AWG or kcmil N/A |
Neutral Wires N/A |
Neutral Size AWG N/A |
Neutral Size N/A |
Sequence Impedance Pos/Neg (µΩ/feet) N/A |
Seq Impedance Zero (µΩ/feet) N/A |
Ampacity LF=100% (A) N/A |
Ampacity LF=75% (A) N/A |
Conductor Size (AWG or kcmil) N/A |
Neutral Wires N/A |
Neutral Size (AWG) N/A |
Conductor Resistance @ 20º C (Ω / 1000 ft) N/A |
Capacitance (μF / 1000 ft) N/A |
Short-Circuit Current - Conductor - 8 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 8 Cycles - (A) N/A |
Short-Circuit Current - Conductor - 16 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 16 Cycles - (A) N/A |
Short-Circuit Current - Conductor - 24 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 24 Cycles - (A) N/A |
A900-04MC350 |
Size of Cable N/A 900-900-900-900+350 |
Phase Conductor Size AWG/MCM N/A 900 |
Number of Phase Conductors N/A 4 |
Diameter of Conductor (mils) N/A 1000 |
Thickness of Conductor Insulation (mils) N/A 80 |
Size of Ground Conductor AWG/MCM N/A 350 |
Diameter of Ground (mils) N/A 614 |
Thickness of Ground Insulation (mils) N/A 65 |
Cabling Diameter (mils) N/A 2957 |
Overall Diameter of Cable Over Armour (mils) N/A 3280 |
AL Weight (lb/mft) N/A 4204 |
Cable Weight (lb/mft) N/A 4204 |
Conductor Size AWG or kcmil N/A |
Neutral Wires N/A |
Neutral Size AWG N/A |
Neutral Size N/A |
Sequence Impedance Pos/Neg (µΩ/feet) N/A |
Seq Impedance Zero (µΩ/feet) N/A |
Ampacity LF=100% (A) N/A |
Ampacity LF=75% (A) N/A |
Conductor Size (AWG or kcmil) N/A |
Neutral Wires N/A |
Neutral Size (AWG) N/A |
Conductor Resistance @ 20º C (Ω / 1000 ft) N/A |
Capacitance (μF / 1000 ft) N/A |
Short-Circuit Current - Conductor - 8 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 8 Cycles - (A) N/A |
Short-Circuit Current - Conductor - 16 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 16 Cycles - (A) N/A |
Short-Circuit Current - Conductor - 24 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 24 Cycles - (A) N/A |
A900-04MC400 |
Size of Cable N/A 900-900-900-900+400 |
Phase Conductor Size AWG/MCM N/A 900 |
Number of Phase Conductors N/A 4 |
Diameter of Conductor (mils) N/A 1000 |
Thickness of Conductor Insulation (mils) N/A 80 |
Size of Ground Conductor AWG/MCM N/A 400 |
Diameter of Ground (mils) N/A 657 |
Thickness of Ground Insulation (mils) N/A 65 |
Cabling Diameter (mils) N/A 2957 |
Overall Diameter of Cable Over Armour (mils) N/A 3280 |
AL Weight (lb/mft) N/A 4251 |
Cable Weight (lb/mft) N/A 4251 |
Conductor Size AWG or kcmil N/A |
Neutral Wires N/A |
Neutral Size AWG N/A |
Neutral Size N/A |
Sequence Impedance Pos/Neg (µΩ/feet) N/A |
Seq Impedance Zero (µΩ/feet) N/A |
Ampacity LF=100% (A) N/A |
Ampacity LF=75% (A) N/A |
Conductor Size (AWG or kcmil) N/A |
Neutral Wires N/A |
Neutral Size (AWG) N/A |
Conductor Resistance @ 20º C (Ω / 1000 ft) N/A |
Capacitance (μF / 1000 ft) N/A |
Short-Circuit Current - Conductor - 8 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 8 Cycles - (A) N/A |
Short-Circuit Current - Conductor - 16 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 16 Cycles - (A) N/A |
Short-Circuit Current - Conductor - 24 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 24 Cycles - (A) N/A |
A900-04MC450 |
Size of Cable N/A 900-900-900-900+450 |
Phase Conductor Size AWG/MCM N/A 900 |
Number of Phase Conductors N/A 4 |
Diameter of Conductor (mils) N/A 1000 |
Thickness of Conductor Insulation (mils) N/A 80 |
Size of Ground Conductor AWG/MCM N/A 450 |
Diameter of Ground (mils) N/A 701 |
Thickness of Ground Insulation (mils) N/A 65 |
Cabling Diameter (mils) N/A 3016 |
Overall Diameter of Cable Over Armour (mils) N/A 3339 |
AL Weight (lb/mft) N/A 4307 |
Cable Weight (lb/mft) N/A 4307 |
Conductor Size AWG or kcmil N/A |
Neutral Wires N/A |
Neutral Size AWG N/A |
Neutral Size N/A |
Sequence Impedance Pos/Neg (µΩ/feet) N/A |
Seq Impedance Zero (µΩ/feet) N/A |
Ampacity LF=100% (A) N/A |
Ampacity LF=75% (A) N/A |
Conductor Size (AWG or kcmil) N/A |
Neutral Wires N/A |
Neutral Size (AWG) N/A |
Conductor Resistance @ 20º C (Ω / 1000 ft) N/A |
Capacitance (μF / 1000 ft) N/A |
Short-Circuit Current - Conductor - 8 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 8 Cycles - (A) N/A |
Short-Circuit Current - Conductor - 16 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 16 Cycles - (A) N/A |
Short-Circuit Current - Conductor - 24 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 24 Cycles - (A) N/A |
A900-04MC500 |
Size of Cable N/A 900-900-900-900+500 |
Phase Conductor Size AWG/MCM N/A 900 |
Number of Phase Conductors N/A 4 |
Diameter of Conductor (mils) N/A 1000 |
Thickness of Conductor Insulation (mils) N/A 80 |
Size of Ground Conductor AWG/MCM N/A 500 |
Diameter of Ground (mils) N/A 736 |
Thickness of Ground Insulation (mils) N/A 65 |
Cabling Diameter (mils) N/A 3016 |
Overall Diameter of Cable Over Armour (mils) N/A 3339 |
AL Weight (lb/mft) N/A 4353 |
Cable Weight (lb/mft) N/A 4353 |
Conductor Size AWG or kcmil N/A |
Neutral Wires N/A |
Neutral Size AWG N/A |
Neutral Size N/A |
Sequence Impedance Pos/Neg (µΩ/feet) N/A |
Seq Impedance Zero (µΩ/feet) N/A |
Ampacity LF=100% (A) N/A |
Ampacity LF=75% (A) N/A |
Conductor Size (AWG or kcmil) N/A |
Neutral Wires N/A |
Neutral Size (AWG) N/A |
Conductor Resistance @ 20º C (Ω / 1000 ft) N/A |
Capacitance (μF / 1000 ft) N/A |
Short-Circuit Current - Conductor - 8 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 8 Cycles - (A) N/A |
Short-Circuit Current - Conductor - 16 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 16 Cycles - (A) N/A |
Short-Circuit Current - Conductor - 24 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 24 Cycles - (A) N/A |
A900-04MC600 |
Size of Cable N/A 900-900-900-900+600 |
Phase Conductor Size AWG/MCM N/A 900 |
Number of Phase Conductors N/A 4 |
Diameter of Conductor (mils) N/A 1000 |
Thickness of Conductor Insulation (mils) N/A 80 |
Size of Ground Conductor AWG/MCM N/A 600 |
Diameter of Ground (mils) N/A 815 |
Thickness of Ground Insulation (mils) N/A 80 |
Cabling Diameter (mils) N/A 3075 |
Overall Diameter of Cable Over Armour (mils) N/A 3398 |
AL Weight (lb/mft) N/A 4456 |
Cable Weight (lb/mft) N/A 4456 |
Conductor Size AWG or kcmil N/A |
Neutral Wires N/A |
Neutral Size AWG N/A |
Neutral Size N/A |
Sequence Impedance Pos/Neg (µΩ/feet) N/A |
Seq Impedance Zero (µΩ/feet) N/A |
Ampacity LF=100% (A) N/A |
Ampacity LF=75% (A) N/A |
Conductor Size (AWG or kcmil) N/A |
Neutral Wires N/A |
Neutral Size (AWG) N/A |
Conductor Resistance @ 20º C (Ω / 1000 ft) N/A |
Capacitance (μF / 1000 ft) N/A |
Short-Circuit Current - Conductor - 8 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 8 Cycles - (A) N/A |
Short-Circuit Current - Conductor - 16 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 16 Cycles - (A) N/A |
Short-Circuit Current - Conductor - 24 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 24 Cycles - (A) N/A |
A900-04MC700 |
Size of Cable N/A 900-900-900-900+700 |
Phase Conductor Size AWG/MCM N/A 900 |
Number of Phase Conductors N/A 4 |
Diameter of Conductor (mils) N/A 1000 |
Thickness of Conductor Insulation (mils) N/A 80 |
Size of Ground Conductor AWG/MCM N/A 700 |
Diameter of Ground (mils) N/A 878 |
Thickness of Ground Insulation (mils) N/A 80 |
Cabling Diameter (mils) N/A 3075 |
Overall Diameter of Cable Over Armour (mils) N/A 3398 |
AL Weight (lb/mft) N/A 4549 |
Cable Weight (lb/mft) N/A 4549 |
Conductor Size AWG or kcmil N/A |
Neutral Wires N/A |
Neutral Size AWG N/A |
Neutral Size N/A |
Sequence Impedance Pos/Neg (µΩ/feet) N/A |
Seq Impedance Zero (µΩ/feet) N/A |
Ampacity LF=100% (A) N/A |
Ampacity LF=75% (A) N/A |
Conductor Size (AWG or kcmil) N/A |
Neutral Wires N/A |
Neutral Size (AWG) N/A |
Conductor Resistance @ 20º C (Ω / 1000 ft) N/A |
Capacitance (μF / 1000 ft) N/A |
Short-Circuit Current - Conductor - 8 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 8 Cycles - (A) N/A |
Short-Circuit Current - Conductor - 16 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 16 Cycles - (A) N/A |
Short-Circuit Current - Conductor - 24 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 24 Cycles - (A) N/A |
A900-04MC750 |
Size of Cable N/A 900-900-900-900+750 |
Phase Conductor Size AWG/MCM N/A 900 |
Number of Phase Conductors N/A 4 |
Diameter of Conductor (mils) N/A 1000 |
Thickness of Conductor Insulation (mils) N/A 80 |
Size of Ground Conductor AWG/MCM N/A 750 |
Diameter of Ground (mils) N/A 909 |
Thickness of Ground Insulation (mils) N/A 80 |
Cabling Diameter (mils) N/A 3130 |
Overall Diameter of Cable Over Armour (mils) N/A 3454 |
AL Weight (lb/mft) N/A 4605 |
Cable Weight (lb/mft) N/A 4605 |
Conductor Size AWG or kcmil N/A |
Neutral Wires N/A |
Neutral Size AWG N/A |
Neutral Size N/A |
Sequence Impedance Pos/Neg (µΩ/feet) N/A |
Seq Impedance Zero (µΩ/feet) N/A |
Ampacity LF=100% (A) N/A |
Ampacity LF=75% (A) N/A |
Conductor Size (AWG or kcmil) N/A |
Neutral Wires N/A |
Neutral Size (AWG) N/A |
Conductor Resistance @ 20º C (Ω / 1000 ft) N/A |
Capacitance (μF / 1000 ft) N/A |
Short-Circuit Current - Conductor - 8 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 8 Cycles - (A) N/A |
Short-Circuit Current - Conductor - 16 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 16 Cycles - (A) N/A |
Short-Circuit Current - Conductor - 24 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 24 Cycles - (A) N/A |
A900-04MC800 |
Size of Cable N/A 900-900-900-900+800 |
Phase Conductor Size AWG/MCM N/A 900 |
Number of Phase Conductors N/A 4 |
Diameter of Conductor (mils) N/A 1000 |
Thickness of Conductor Insulation (mils) N/A 80 |
Size of Ground Conductor AWG/MCM N/A 800 |
Diameter of Ground (mils) N/A 937 |
Thickness of Ground Insulation (mils) N/A 80 |
Cabling Diameter (mils) N/A 3130 |
Overall Diameter of Cable Over Armour (mils) N/A 3454 |
AL Weight (lb/mft) N/A 4650 |
Cable Weight (lb/mft) N/A 4650 |
Conductor Size AWG or kcmil N/A |
Neutral Wires N/A |
Neutral Size AWG N/A |
Neutral Size N/A |
Sequence Impedance Pos/Neg (µΩ/feet) N/A |
Seq Impedance Zero (µΩ/feet) N/A |
Ampacity LF=100% (A) N/A |
Ampacity LF=75% (A) N/A |
Conductor Size (AWG or kcmil) N/A |
Neutral Wires N/A |
Neutral Size (AWG) N/A |
Conductor Resistance @ 20º C (Ω / 1000 ft) N/A |
Capacitance (μF / 1000 ft) N/A |
Short-Circuit Current - Conductor - 8 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 8 Cycles - (A) N/A |
Short-Circuit Current - Conductor - 16 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 16 Cycles - (A) N/A |
Short-Circuit Current - Conductor - 24 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 24 Cycles - (A) N/A |
A900-04MC900 |
Size of Cable N/A 900-900-900-900+900 |
Phase Conductor Size AWG/MCM N/A 900 |
Number of Phase Conductors N/A 4 |
Diameter of Conductor (mils) N/A 1000 |
Thickness of Conductor Insulation (mils) N/A 80 |
Size of Ground Conductor AWG/MCM N/A 900 |
Diameter of Ground (mils) N/A 1000 |
Thickness of Ground Insulation (mils) N/A 80 |
Cabling Diameter (mils) N/A 3130 |
Overall Diameter of Cable Over Armour (mils) N/A 3454 |
AL Weight (lb/mft) N/A 4743 |
Cable Weight (lb/mft) N/A 4743 |
Conductor Size AWG or kcmil N/A |
Neutral Wires N/A |
Neutral Size AWG N/A |
Neutral Size N/A |
Sequence Impedance Pos/Neg (µΩ/feet) N/A |
Seq Impedance Zero (µΩ/feet) N/A |
Ampacity LF=100% (A) N/A |
Ampacity LF=75% (A) N/A |
Conductor Size (AWG or kcmil) N/A |
Neutral Wires N/A |
Neutral Size (AWG) N/A |
Conductor Resistance @ 20º C (Ω / 1000 ft) N/A |
Capacitance (μF / 1000 ft) N/A |
Short-Circuit Current - Conductor - 8 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 8 Cycles - (A) N/A |
Short-Circuit Current - Conductor - 16 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 16 Cycles - (A) N/A |
Short-Circuit Current - Conductor - 24 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 24 Cycles - (A) N/A |
A900-04MC1000 |
Size of Cable N/A 900-900-900-900+1000 |
Phase Conductor Size AWG/MCM N/A 900 |
Number of Phase Conductors N/A 4 |
Diameter of Conductor (mils) N/A 1000 |
Thickness of Conductor Insulation (mils) N/A 80 |
Size of Ground Conductor AWG/MCM N/A 1000 |
Diameter of Ground (mils) N/A 1059 |
Thickness of Ground Insulation (mils) N/A 80 |
Cabling Diameter (mils) N/A 3130 |
Overall Diameter of Cable Over Armour (mils) N/A 3454 |
AL Weight (lb/mft) N/A 4835 |
Cable Weight (lb/mft) N/A 4835 |
Conductor Size AWG or kcmil N/A |
Neutral Wires N/A |
Neutral Size AWG N/A |
Neutral Size N/A |
Sequence Impedance Pos/Neg (µΩ/feet) N/A |
Seq Impedance Zero (µΩ/feet) N/A |
Ampacity LF=100% (A) N/A |
Ampacity LF=75% (A) N/A |
Conductor Size (AWG or kcmil) N/A |
Neutral Wires N/A |
Neutral Size (AWG) N/A |
Conductor Resistance @ 20º C (Ω / 1000 ft) N/A |
Capacitance (μF / 1000 ft) N/A |
Short-Circuit Current - Conductor - 8 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 8 Cycles - (A) N/A |
Short-Circuit Current - Conductor - 16 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 16 Cycles - (A) N/A |
Short-Circuit Current - Conductor - 24 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 24 Cycles - (A) N/A |
A1000-04MC2/0 |
Size of Cable N/A 1000-1000-1000-1000+2/0 |
Phase Conductor Size AWG/MCM N/A 1000 |
Number of Phase Conductors N/A 4 |
Diameter of Conductor (mils) N/A 1059 |
Thickness of Conductor Insulation (mils) N/A 80 |
Size of Ground Conductor AWG/MCM N/A 2/0 |
Diameter of Ground (mils) N/A 376 |
Thickness of Ground Insulation (mils) N/A 55 |
Cabling Diameter (mils) N/A 2949 |
Overall Diameter of Cable Over Armour (mils) N/A 3272 |
AL Weight (lb/mft) N/A 4374 |
Cable Weight (lb/mft) N/A 4374 |
Conductor Size AWG or kcmil N/A |
Neutral Wires N/A |
Neutral Size AWG N/A |
Neutral Size N/A |
Sequence Impedance Pos/Neg (µΩ/feet) N/A |
Seq Impedance Zero (µΩ/feet) N/A |
Ampacity LF=100% (A) N/A |
Ampacity LF=75% (A) N/A |
Conductor Size (AWG or kcmil) N/A |
Neutral Wires N/A |
Neutral Size (AWG) N/A |
Conductor Resistance @ 20º C (Ω / 1000 ft) N/A |
Capacitance (μF / 1000 ft) N/A |
Short-Circuit Current - Conductor - 8 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 8 Cycles - (A) N/A |
Short-Circuit Current - Conductor - 16 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 16 Cycles - (A) N/A |
Short-Circuit Current - Conductor - 24 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 24 Cycles - (A) N/A |
A1000-04MC3/0 |
Size of Cable N/A 1000-1000-1000-1000+3/0 |
Phase Conductor Size AWG/MCM N/A 1000 |
Number of Phase Conductors N/A 4 |
Diameter of Conductor (mils) N/A 1059 |
Thickness of Conductor Insulation (mils) N/A 80 |
Size of Ground Conductor AWG/MCM N/A 3/0 |
Diameter of Ground (mils) N/A 421 |
Thickness of Ground Insulation (mils) N/A 55 |
Cabling Diameter (mils) N/A 3024 |
Overall Diameter of Cable Over Armour (mils) N/A 3347 |
AL Weight (lb/mft) N/A 4420 |
Cable Weight (lb/mft) N/A 4420 |
Conductor Size AWG or kcmil N/A |
Neutral Wires N/A |
Neutral Size AWG N/A |
Neutral Size N/A |
Sequence Impedance Pos/Neg (µΩ/feet) N/A |
Seq Impedance Zero (µΩ/feet) N/A |
Ampacity LF=100% (A) N/A |
Ampacity LF=75% (A) N/A |
Conductor Size (AWG or kcmil) N/A |
Neutral Wires N/A |
Neutral Size (AWG) N/A |
Conductor Resistance @ 20º C (Ω / 1000 ft) N/A |
Capacitance (μF / 1000 ft) N/A |
Short-Circuit Current - Conductor - 8 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 8 Cycles - (A) N/A |
Short-Circuit Current - Conductor - 16 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 16 Cycles - (A) N/A |
Short-Circuit Current - Conductor - 24 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 24 Cycles - (A) N/A |
A1000-04MC4/0 |
Size of Cable N/A 1000-1000-1000-1000+4/0 |
Phase Conductor Size AWG/MCM N/A 1000 |
Number of Phase Conductors N/A 4 |
Diameter of Conductor (mils) N/A 1059 |
Thickness of Conductor Insulation (mils) N/A 80 |
Size of Ground Conductor AWG/MCM N/A 4/0 |
Diameter of Ground (mils) N/A 476 |
Thickness of Ground Insulation (mils) N/A 55 |
Cabling Diameter (mils) N/A 3024 |
Overall Diameter of Cable Over Armour (mils) N/A 3347 |
AL Weight (lb/mft) N/A 4459 |
Cable Weight (lb/mft) N/A 4459 |
Conductor Size AWG or kcmil N/A |
Neutral Wires N/A |
Neutral Size AWG N/A |
Neutral Size N/A |
Sequence Impedance Pos/Neg (µΩ/feet) N/A |
Seq Impedance Zero (µΩ/feet) N/A |
Ampacity LF=100% (A) N/A |
Ampacity LF=75% (A) N/A |
Conductor Size (AWG or kcmil) N/A |
Neutral Wires N/A |
Neutral Size (AWG) N/A |
Conductor Resistance @ 20º C (Ω / 1000 ft) N/A |
Capacitance (μF / 1000 ft) N/A |
Short-Circuit Current - Conductor - 8 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 8 Cycles - (A) N/A |
Short-Circuit Current - Conductor - 16 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 16 Cycles - (A) N/A |
Short-Circuit Current - Conductor - 24 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 24 Cycles - (A) N/A |
A1000-04MC250 |
Size of Cable N/A 1000-1000-1000-1000+250 |
Phase Conductor Size AWG/MCM N/A 1000 |
Number of Phase Conductors N/A 4 |
Diameter of Conductor (mils) N/A 1059 |
Thickness of Conductor Insulation (mils) N/A 80 |
Size of Ground Conductor AWG/MCM N/A 250 |
Diameter of Ground (mils) N/A 520 |
Thickness of Ground Insulation (mils) N/A 65 |
Cabling Diameter (mils) N/A 3047 |
Overall Diameter of Cable Over Armour (mils) N/A 3371 |
AL Weight (lb/mft) N/A 4500 |
Cable Weight (lb/mft) N/A 4500 |
Conductor Size AWG or kcmil N/A |
Neutral Wires N/A |
Neutral Size AWG N/A |
Neutral Size N/A |
Sequence Impedance Pos/Neg (µΩ/feet) N/A |
Seq Impedance Zero (µΩ/feet) N/A |
Ampacity LF=100% (A) N/A |
Ampacity LF=75% (A) N/A |
Conductor Size (AWG or kcmil) N/A |
Neutral Wires N/A |
Neutral Size (AWG) N/A |
Conductor Resistance @ 20º C (Ω / 1000 ft) N/A |
Capacitance (μF / 1000 ft) N/A |
Short-Circuit Current - Conductor - 8 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 8 Cycles - (A) N/A |
Short-Circuit Current - Conductor - 16 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 16 Cycles - (A) N/A |
Short-Circuit Current - Conductor - 24 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 24 Cycles - (A) N/A |
A1000-04MC300 |
Size of Cable N/A 1000-1000-1000-1000+300 |
Phase Conductor Size AWG/MCM N/A 1000 |
Number of Phase Conductors N/A 4 |
Diameter of Conductor (mils) N/A 1059 |
Thickness of Conductor Insulation (mils) N/A 80 |
Size of Ground Conductor AWG/MCM N/A 300 |
Diameter of Ground (mils) N/A 571 |
Thickness of Ground Insulation (mils) N/A 65 |
Cabling Diameter (mils) N/A 3047 |
Overall Diameter of Cable Over Armour (mils) N/A 3371 |
AL Weight (lb/mft) N/A 4546 |
Cable Weight (lb/mft) N/A 4546 |
Conductor Size AWG or kcmil N/A |
Neutral Wires N/A |
Neutral Size AWG N/A |
Neutral Size N/A |
Sequence Impedance Pos/Neg (µΩ/feet) N/A |
Seq Impedance Zero (µΩ/feet) N/A |
Ampacity LF=100% (A) N/A |
Ampacity LF=75% (A) N/A |
Conductor Size (AWG or kcmil) N/A |
Neutral Wires N/A |
Neutral Size (AWG) N/A |
Conductor Resistance @ 20º C (Ω / 1000 ft) N/A |
Capacitance (μF / 1000 ft) N/A |
Short-Circuit Current - Conductor - 8 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 8 Cycles - (A) N/A |
Short-Circuit Current - Conductor - 16 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 16 Cycles - (A) N/A |
Short-Circuit Current - Conductor - 24 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 24 Cycles - (A) N/A |
A1000-04MC350 |
Size of Cable N/A 1000-1000-1000-1000+350 |
Phase Conductor Size AWG/MCM N/A 1000 |
Number of Phase Conductors N/A 4 |
Diameter of Conductor (mils) N/A 1059 |
Thickness of Conductor Insulation (mils) N/A 80 |
Size of Ground Conductor AWG/MCM N/A 350 |
Diameter of Ground (mils) N/A 614 |
Thickness of Ground Insulation (mils) N/A 65 |
Cabling Diameter (mils) N/A 3106 |
Overall Diameter of Cable Over Armour (mils) N/A 3430 |
AL Weight (lb/mft) N/A 4602 |
Cable Weight (lb/mft) N/A 4602 |
Conductor Size AWG or kcmil N/A |
Neutral Wires N/A |
Neutral Size AWG N/A |
Neutral Size N/A |
Sequence Impedance Pos/Neg (µΩ/feet) N/A |
Seq Impedance Zero (µΩ/feet) N/A |
Ampacity LF=100% (A) N/A |
Ampacity LF=75% (A) N/A |
Conductor Size (AWG or kcmil) N/A |
Neutral Wires N/A |
Neutral Size (AWG) N/A |
Conductor Resistance @ 20º C (Ω / 1000 ft) N/A |
Capacitance (μF / 1000 ft) N/A |
Short-Circuit Current - Conductor - 8 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 8 Cycles - (A) N/A |
Short-Circuit Current - Conductor - 16 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 16 Cycles - (A) N/A |
Short-Circuit Current - Conductor - 24 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 24 Cycles - (A) N/A |
A1000-04MC400 |
Size of Cable N/A 1000-1000-1000-1000+400 |
Phase Conductor Size AWG/MCM N/A 1000 |
Number of Phase Conductors N/A 4 |
Diameter of Conductor (mils) N/A 1059 |
Thickness of Conductor Insulation (mils) N/A 80 |
Size of Ground Conductor AWG/MCM N/A 400 |
Diameter of Ground (mils) N/A 657 |
Thickness of Ground Insulation (mils) N/A 65 |
Cabling Diameter (mils) N/A 3106 |
Overall Diameter of Cable Over Armour (mils) N/A 3430 |
AL Weight (lb/mft) N/A 4649 |
Cable Weight (lb/mft) N/A 4649 |
Conductor Size AWG or kcmil N/A |
Neutral Wires N/A |
Neutral Size AWG N/A |
Neutral Size N/A |
Sequence Impedance Pos/Neg (µΩ/feet) N/A |
Seq Impedance Zero (µΩ/feet) N/A |
Ampacity LF=100% (A) N/A |
Ampacity LF=75% (A) N/A |
Conductor Size (AWG or kcmil) N/A |
Neutral Wires N/A |
Neutral Size (AWG) N/A |
Conductor Resistance @ 20º C (Ω / 1000 ft) N/A |
Capacitance (μF / 1000 ft) N/A |
Short-Circuit Current - Conductor - 8 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 8 Cycles - (A) N/A |
Short-Circuit Current - Conductor - 16 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 16 Cycles - (A) N/A |
Short-Circuit Current - Conductor - 24 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 24 Cycles - (A) N/A |
A1000-04MC450 |
Size of Cable N/A 1000-1000-1000-1000+450 |
Phase Conductor Size AWG/MCM N/A 1000 |
Number of Phase Conductors N/A 4 |
Diameter of Conductor (mils) N/A 1059 |
Thickness of Conductor Insulation (mils) N/A 80 |
Size of Ground Conductor AWG/MCM N/A 450 |
Diameter of Ground (mils) N/A 701 |
Thickness of Ground Insulation (mils) N/A 65 |
Cabling Diameter (mils) N/A 3106 |
Overall Diameter of Cable Over Armour (mils) N/A 3430 |
AL Weight (lb/mft) N/A 4695 |
Cable Weight (lb/mft) N/A 4695 |
Conductor Size AWG or kcmil N/A |
Neutral Wires N/A |
Neutral Size AWG N/A |
Neutral Size N/A |
Sequence Impedance Pos/Neg (µΩ/feet) N/A |
Seq Impedance Zero (µΩ/feet) N/A |
Ampacity LF=100% (A) N/A |
Ampacity LF=75% (A) N/A |
Conductor Size (AWG or kcmil) N/A |
Neutral Wires N/A |
Neutral Size (AWG) N/A |
Conductor Resistance @ 20º C (Ω / 1000 ft) N/A |
Capacitance (μF / 1000 ft) N/A |
Short-Circuit Current - Conductor - 8 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 8 Cycles - (A) N/A |
Short-Circuit Current - Conductor - 16 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 16 Cycles - (A) N/A |
Short-Circuit Current - Conductor - 24 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 24 Cycles - (A) N/A |
A1000-04MC500 |
Size of Cable N/A 1000-1000-1000-1000+500 |
Phase Conductor Size AWG/MCM N/A 1000 |
Number of Phase Conductors N/A 4 |
Diameter of Conductor (mils) N/A 1059 |
Thickness of Conductor Insulation (mils) N/A 80 |
Size of Ground Conductor AWG/MCM N/A 500 |
Diameter of Ground (mils) N/A 736 |
Thickness of Ground Insulation (mils) N/A 65 |
Cabling Diameter (mils) N/A 3169 |
Overall Diameter of Cable Over Armour (mils) N/A 3493 |
AL Weight (lb/mft) N/A 4752 |
Cable Weight (lb/mft) N/A 4752 |
Conductor Size AWG or kcmil N/A |
Neutral Wires N/A |
Neutral Size AWG N/A |
Neutral Size N/A |
Sequence Impedance Pos/Neg (µΩ/feet) N/A |
Seq Impedance Zero (µΩ/feet) N/A |
Ampacity LF=100% (A) N/A |
Ampacity LF=75% (A) N/A |
Conductor Size (AWG or kcmil) N/A |
Neutral Wires N/A |
Neutral Size (AWG) N/A |
Conductor Resistance @ 20º C (Ω / 1000 ft) N/A |
Capacitance (μF / 1000 ft) N/A |
Short-Circuit Current - Conductor - 8 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 8 Cycles - (A) N/A |
Short-Circuit Current - Conductor - 16 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 16 Cycles - (A) N/A |
Short-Circuit Current - Conductor - 24 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 24 Cycles - (A) N/A |
A1000-04MC600 |
Size of Cable N/A 1000-1000-1000-1000+600 |
Phase Conductor Size AWG/MCM N/A 1000 |
Number of Phase Conductors N/A 4 |
Diameter of Conductor (mils) N/A 1059 |
Thickness of Conductor Insulation (mils) N/A 80 |
Size of Ground Conductor AWG/MCM N/A 600 |
Diameter of Ground (mils) N/A 815 |
Thickness of Ground Insulation (mils) N/A 80 |
Cabling Diameter (mils) N/A 3228 |
Overall Diameter of Cable Over Armour (mils) N/A 3552 |
AL Weight (lb/mft) N/A 4856 |
Cable Weight (lb/mft) N/A 4856 |
Conductor Size AWG or kcmil N/A |
Neutral Wires N/A |
Neutral Size AWG N/A |
Neutral Size N/A |
Sequence Impedance Pos/Neg (µΩ/feet) N/A |
Seq Impedance Zero (µΩ/feet) N/A |
Ampacity LF=100% (A) N/A |
Ampacity LF=75% (A) N/A |
Conductor Size (AWG or kcmil) N/A |
Neutral Wires N/A |
Neutral Size (AWG) N/A |
Conductor Resistance @ 20º C (Ω / 1000 ft) N/A |
Capacitance (μF / 1000 ft) N/A |
Short-Circuit Current - Conductor - 8 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 8 Cycles - (A) N/A |
Short-Circuit Current - Conductor - 16 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 16 Cycles - (A) N/A |
Short-Circuit Current - Conductor - 24 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 24 Cycles - (A) N/A |
A1000-04MC650 |
Size of Cable N/A 1000-1000-1000-1000+650 |
Phase Conductor Size AWG/MCM N/A 1000 |
Number of Phase Conductors N/A 4 |
Diameter of Conductor (mils) N/A 1059 |
Thickness of Conductor Insulation (mils) N/A 80 |
Size of Ground Conductor AWG/MCM N/A 650 |
Diameter of Ground (mils) N/A 843 |
Thickness of Ground Insulation (mils) N/A 80 |
Cabling Diameter (mils) N/A 3228 |
Overall Diameter of Cable Over Armour (mils) N/A 3552 |
AL Weight (lb/mft) N/A 4901 |
Cable Weight (lb/mft) N/A 4901 |
Conductor Size AWG or kcmil N/A |
Neutral Wires N/A |
Neutral Size AWG N/A |
Neutral Size N/A |
Sequence Impedance Pos/Neg (µΩ/feet) N/A |
Seq Impedance Zero (µΩ/feet) N/A |
Ampacity LF=100% (A) N/A |
Ampacity LF=75% (A) N/A |
Conductor Size (AWG or kcmil) N/A |
Neutral Wires N/A |
Neutral Size (AWG) N/A |
Conductor Resistance @ 20º C (Ω / 1000 ft) N/A |
Capacitance (μF / 1000 ft) N/A |
Short-Circuit Current - Conductor - 8 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 8 Cycles - (A) N/A |
Short-Circuit Current - Conductor - 16 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 16 Cycles - (A) N/A |
Short-Circuit Current - Conductor - 24 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 24 Cycles - (A) N/A |
A1000-04MC700 |
Size of Cable N/A 1000-1000-1000-1000+700 |
Phase Conductor Size AWG/MCM N/A 1000 |
Number of Phase Conductors N/A 4 |
Diameter of Conductor (mils) N/A 1059 |
Thickness of Conductor Insulation (mils) N/A 80 |
Size of Ground Conductor AWG/MCM N/A 700 |
Diameter of Ground (mils) N/A 878 |
Thickness of Ground Insulation (mils) N/A 80 |
Cabling Diameter (mils) N/A 3228 |
Overall Diameter of Cable Over Armour (mils) N/A 3552 |
AL Weight (lb/mft) N/A 4948 |
Cable Weight (lb/mft) N/A 4948 |
Conductor Size AWG or kcmil N/A |
Neutral Wires N/A |
Neutral Size AWG N/A |
Neutral Size N/A |
Sequence Impedance Pos/Neg (µΩ/feet) N/A |
Seq Impedance Zero (µΩ/feet) N/A |
Ampacity LF=100% (A) N/A |
Ampacity LF=75% (A) N/A |
Conductor Size (AWG or kcmil) N/A |
Neutral Wires N/A |
Neutral Size (AWG) N/A |
Conductor Resistance @ 20º C (Ω / 1000 ft) N/A |
Capacitance (μF / 1000 ft) N/A |
Short-Circuit Current - Conductor - 8 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 8 Cycles - (A) N/A |
Short-Circuit Current - Conductor - 16 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 16 Cycles - (A) N/A |
Short-Circuit Current - Conductor - 24 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 24 Cycles - (A) N/A |
A1000-04MC750 |
Size of Cable N/A 1000-1000-1000-1000+750 |
Phase Conductor Size AWG/MCM N/A 1000 |
Number of Phase Conductors N/A 4 |
Diameter of Conductor (mils) N/A 1059 |
Thickness of Conductor Insulation (mils) N/A 80 |
Size of Ground Conductor AWG/MCM N/A 750 |
Diameter of Ground (mils) N/A 909 |
Thickness of Ground Insulation (mils) N/A 80 |
Cabling Diameter (mils) N/A 3228 |
Overall Diameter of Cable Over Armour (mils) N/A 3552 |
AL Weight (lb/mft) N/A 4994 |
Cable Weight (lb/mft) N/A 4994 |
Conductor Size AWG or kcmil N/A |
Neutral Wires N/A |
Neutral Size AWG N/A |
Neutral Size N/A |
Sequence Impedance Pos/Neg (µΩ/feet) N/A |
Seq Impedance Zero (µΩ/feet) N/A |
Ampacity LF=100% (A) N/A |
Ampacity LF=75% (A) N/A |
Conductor Size (AWG or kcmil) N/A |
Neutral Wires N/A |
Neutral Size (AWG) N/A |
Conductor Resistance @ 20º C (Ω / 1000 ft) N/A |
Capacitance (μF / 1000 ft) N/A |
Short-Circuit Current - Conductor - 8 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 8 Cycles - (A) N/A |
Short-Circuit Current - Conductor - 16 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 16 Cycles - (A) N/A |
Short-Circuit Current - Conductor - 24 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 24 Cycles - (A) N/A |
A1000-04MC800 |
Size of Cable N/A 1000-1000-1000-1000+800 |
Phase Conductor Size AWG/MCM N/A 1000 |
Number of Phase Conductors N/A 4 |
Diameter of Conductor (mils) N/A 1059 |
Thickness of Conductor Insulation (mils) N/A 80 |
Size of Ground Conductor AWG/MCM N/A 800 |
Diameter of Ground (mils) N/A 937 |
Thickness of Ground Insulation (mils) N/A 80 |
Cabling Diameter (mils) N/A 3228 |
Overall Diameter of Cable Over Armour (mils) N/A 3552 |
AL Weight (lb/mft) N/A 5039 |
Cable Weight (lb/mft) N/A 5039 |
Conductor Size AWG or kcmil N/A |
Neutral Wires N/A |
Neutral Size AWG N/A |
Neutral Size N/A |
Sequence Impedance Pos/Neg (µΩ/feet) N/A |
Seq Impedance Zero (µΩ/feet) N/A |
Ampacity LF=100% (A) N/A |
Ampacity LF=75% (A) N/A |
Conductor Size (AWG or kcmil) N/A |
Neutral Wires N/A |
Neutral Size (AWG) N/A |
Conductor Resistance @ 20º C (Ω / 1000 ft) N/A |
Capacitance (μF / 1000 ft) N/A |
Short-Circuit Current - Conductor - 8 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 8 Cycles - (A) N/A |
Short-Circuit Current - Conductor - 16 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 16 Cycles - (A) N/A |
Short-Circuit Current - Conductor - 24 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 24 Cycles - (A) N/A |
A1000-04MC900 |
Size of Cable N/A 1000-1000-1000-1000+900 |
Phase Conductor Size AWG/MCM N/A 1000 |
Number of Phase Conductors N/A 4 |
Diameter of Conductor (mils) N/A 1059 |
Thickness of Conductor Insulation (mils) N/A 80 |
Size of Ground Conductor AWG/MCM N/A 900 |
Diameter of Ground (mils) N/A 1000 |
Thickness of Ground Insulation (mils) N/A 80 |
Cabling Diameter (mils) N/A 3291 |
Overall Diameter of Cable Over Armour (mils) N/A 3615 |
AL Weight (lb/mft) N/A 5143 |
Cable Weight (lb/mft) N/A 5143 |
Conductor Size AWG or kcmil N/A |
Neutral Wires N/A |
Neutral Size AWG N/A |
Neutral Size N/A |
Sequence Impedance Pos/Neg (µΩ/feet) N/A |
Seq Impedance Zero (µΩ/feet) N/A |
Ampacity LF=100% (A) N/A |
Ampacity LF=75% (A) N/A |
Conductor Size (AWG or kcmil) N/A |
Neutral Wires N/A |
Neutral Size (AWG) N/A |
Conductor Resistance @ 20º C (Ω / 1000 ft) N/A |
Capacitance (μF / 1000 ft) N/A |
Short-Circuit Current - Conductor - 8 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 8 Cycles - (A) N/A |
Short-Circuit Current - Conductor - 16 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 16 Cycles - (A) N/A |
Short-Circuit Current - Conductor - 24 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 24 Cycles - (A) N/A |
A1000-04MC1000 |
Size of Cable N/A 1000-1000-1000-1000+1000 |
Phase Conductor Size AWG/MCM N/A 1000 |
Number of Phase Conductors N/A 4 |
Diameter of Conductor (mils) N/A 1059 |
Thickness of Conductor Insulation (mils) N/A 80 |
Size of Ground Conductor AWG/MCM N/A 1000 |
Diameter of Ground (mils) N/A 1059 |
Thickness of Ground Insulation (mils) N/A 80 |
Cabling Diameter (mils) N/A 3291 |
Overall Diameter of Cable Over Armour (mils) N/A 3615 |
AL Weight (lb/mft) N/A 5236 |
Cable Weight (lb/mft) N/A 5236 |
Conductor Size AWG or kcmil N/A |
Neutral Wires N/A |
Neutral Size AWG N/A |
Neutral Size N/A |
Sequence Impedance Pos/Neg (µΩ/feet) N/A |
Seq Impedance Zero (µΩ/feet) N/A |
Ampacity LF=100% (A) N/A |
Ampacity LF=75% (A) N/A |
Conductor Size (AWG or kcmil) N/A |
Neutral Wires N/A |
Neutral Size (AWG) N/A |
Conductor Resistance @ 20º C (Ω / 1000 ft) N/A |
Capacitance (μF / 1000 ft) N/A |
Short-Circuit Current - Conductor - 8 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 8 Cycles - (A) N/A |
Short-Circuit Current - Conductor - 16 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 16 Cycles - (A) N/A |
Short-Circuit Current - Conductor - 24 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 24 Cycles - (A) N/A |
A10-04MC10 |
Size of Cable N/A 10-10-10-10+10 |
Phase Conductor Size AWG/MCM N/A 10 |
Number of Phase Conductors N/A 4 |
Diameter of Conductor (mils) N/A 116 |
Thickness of Conductor Insulation (mils) N/A 30 |
Size of Ground Conductor AWG/MCM N/A 10 |
Diameter of Ground (mils) N/A 116 |
Thickness of Ground Insulation (mils) N/A 30 |
Cabling Diameter (mils) N/A 476 |
Overall Diameter of Cable Over Armour (mils) N/A 750 |
AL Weight (lb/mft) N/A 134 |
Cable Weight (lb/mft) N/A 172 |
Conductor Size AWG or kcmil N/A |
Neutral Wires N/A |
Neutral Size AWG N/A |
Neutral Size N/A |
Sequence Impedance Pos/Neg (µΩ/feet) N/A |
Seq Impedance Zero (µΩ/feet) N/A |
Ampacity LF=100% (A) N/A |
Ampacity LF=75% (A) N/A |
Conductor Size (AWG or kcmil) N/A |
Neutral Wires N/A |
Neutral Size (AWG) N/A |
Conductor Resistance @ 20º C (Ω / 1000 ft) N/A |
Capacitance (μF / 1000 ft) N/A |
Short-Circuit Current - Conductor - 8 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 8 Cycles - (A) N/A |
Short-Circuit Current - Conductor - 16 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 16 Cycles - (A) N/A |
Short-Circuit Current - Conductor - 24 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 24 Cycles - (A) N/A |
A8-04MC10 |
Size of Cable N/A 8-8-8-8+10 |
Phase Conductor Size AWG/MCM N/A 8 |
Number of Phase Conductors N/A 4 |
Diameter of Conductor (mils) N/A 134 |
Thickness of Conductor Insulation (mils) N/A 45 |
Size of Ground Conductor AWG/MCM N/A 10 |
Diameter of Ground (mils) N/A 116 |
Thickness of Ground Insulation (mils) N/A 30 |
Cabling Diameter (mils) N/A 583 |
Overall Diameter of Cable Over Armour (mils) N/A 856 |
AL Weight (lb/mft) N/A 173 |
Cable Weight (lb/mft) N/A 234 |
Conductor Size AWG or kcmil N/A |
Neutral Wires N/A |
Neutral Size AWG N/A |
Neutral Size N/A |
Sequence Impedance Pos/Neg (µΩ/feet) N/A |
Seq Impedance Zero (µΩ/feet) N/A |
Ampacity LF=100% (A) N/A |
Ampacity LF=75% (A) N/A |
Conductor Size (AWG or kcmil) N/A |
Neutral Wires N/A |
Neutral Size (AWG) N/A |
Conductor Resistance @ 20º C (Ω / 1000 ft) N/A |
Capacitance (μF / 1000 ft) N/A |
Short-Circuit Current - Conductor - 8 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 8 Cycles - (A) N/A |
Short-Circuit Current - Conductor - 16 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 16 Cycles - (A) N/A |
Short-Circuit Current - Conductor - 24 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 24 Cycles - (A) N/A |
A8-04MC8 |
Size of Cable N/A 8-8-8-8+8 |
Phase Conductor Size AWG/MCM N/A 8 |
Number of Phase Conductors N/A 4 |
Diameter of Conductor (mils) N/A 134 |
Thickness of Conductor Insulation (mils) N/A 45 |
Size of Ground Conductor AWG/MCM N/A 8 |
Diameter of Ground (mils) N/A 134 |
Thickness of Ground Insulation (mils) N/A 45 |
Cabling Diameter (mils) N/A 606 |
Overall Diameter of Cable Over Armour (mils) N/A 880 |
AL Weight (lb/mft) N/A 182 |
Cable Weight (lb/mft) N/A 250 |
Conductor Size AWG or kcmil N/A |
Neutral Wires N/A |
Neutral Size AWG N/A |
Neutral Size N/A |
Sequence Impedance Pos/Neg (µΩ/feet) N/A |
Seq Impedance Zero (µΩ/feet) N/A |
Ampacity LF=100% (A) N/A |
Ampacity LF=75% (A) N/A |
Conductor Size (AWG or kcmil) N/A |
Neutral Wires N/A |
Neutral Size (AWG) N/A |
Conductor Resistance @ 20º C (Ω / 1000 ft) N/A |
Capacitance (μF / 1000 ft) N/A |
Short-Circuit Current - Conductor - 8 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 8 Cycles - (A) N/A |
Short-Circuit Current - Conductor - 16 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 16 Cycles - (A) N/A |
Short-Circuit Current - Conductor - 24 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 24 Cycles - (A) N/A |
A6-04MC8 |
Size of Cable N/A 6-6-6-6+8 |
Phase Conductor Size AWG/MCM N/A 6 |
Number of Phase Conductors N/A 4 |
Diameter of Conductor (mils) N/A 169 |
Thickness of Conductor Insulation (mils) N/A 45 |
Size of Ground Conductor AWG/MCM N/A 8 |
Diameter of Ground (mils) N/A 134 |
Thickness of Ground Insulation (mils) N/A 45 |
Cabling Diameter (mils) N/A 685 |
Overall Diameter of Cable Over Armour (mils) N/A 959 |
AL Weight (lb/mft) N/A 230 |
Cable Weight (lb/mft) N/A 308 |
Conductor Size AWG or kcmil N/A |
Neutral Wires N/A |
Neutral Size AWG N/A |
Neutral Size N/A |
Sequence Impedance Pos/Neg (µΩ/feet) N/A |
Seq Impedance Zero (µΩ/feet) N/A |
Ampacity LF=100% (A) N/A |
Ampacity LF=75% (A) N/A |
Conductor Size (AWG or kcmil) N/A |
Neutral Wires N/A |
Neutral Size (AWG) N/A |
Conductor Resistance @ 20º C (Ω / 1000 ft) N/A |
Capacitance (μF / 1000 ft) N/A |
Short-Circuit Current - Conductor - 8 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 8 Cycles - (A) N/A |
Short-Circuit Current - Conductor - 16 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 16 Cycles - (A) N/A |
Short-Circuit Current - Conductor - 24 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 24 Cycles - (A) N/A |
A6-04MC6 |
Size of Cable N/A 6-6-6-6+6 |
Phase Conductor Size AWG/MCM N/A 6 |
Number of Phase Conductors N/A 4 |
Diameter of Conductor (mils) N/A 169 |
Thickness of Conductor Insulation (mils) N/A 45 |
Size of Ground Conductor AWG/MCM N/A 6 |
Diameter of Ground (mils) N/A 169 |
Thickness of Ground Insulation (mils) N/A 45 |
Cabling Diameter (mils) N/A 701 |
Overall Diameter of Cable Over Armour (mils) N/A 974 |
AL Weight (lb/mft) N/A 242 |
Cable Weight (lb/mft) N/A 322 |
Conductor Size AWG or kcmil N/A |
Neutral Wires N/A |
Neutral Size AWG N/A |
Neutral Size N/A |
Sequence Impedance Pos/Neg (µΩ/feet) N/A |
Seq Impedance Zero (µΩ/feet) N/A |
Ampacity LF=100% (A) N/A |
Ampacity LF=75% (A) N/A |
Conductor Size (AWG or kcmil) N/A |
Neutral Wires N/A |
Neutral Size (AWG) N/A |
Conductor Resistance @ 20º C (Ω / 1000 ft) N/A |
Capacitance (μF / 1000 ft) N/A |
Short-Circuit Current - Conductor - 8 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 8 Cycles - (A) N/A |
Short-Circuit Current - Conductor - 16 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 16 Cycles - (A) N/A |
Short-Circuit Current - Conductor - 24 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 24 Cycles - (A) N/A |
A4-04MC6 |
Size of Cable N/A 4-4-4-4+6 |
Phase Conductor Size AWG/MCM N/A 4 |
Number of Phase Conductors N/A 4 |
Diameter of Conductor (mils) N/A 213 |
Thickness of Conductor Insulation (mils) N/A 45 |
Size of Ground Conductor AWG/MCM N/A 6 |
Diameter of Ground (mils) N/A 169 |
Thickness of Ground Insulation (mils) N/A 45 |
Cabling Diameter (mils) N/A 803 |
Overall Diameter of Cable Over Armour (mils) N/A 1077 |
AL Weight (lb/mft) N/A 315 |
Cable Weight (lb/mft) N/A 409 |
Conductor Size AWG or kcmil N/A |
Neutral Wires N/A |
Neutral Size AWG N/A |
Neutral Size N/A |
Sequence Impedance Pos/Neg (µΩ/feet) N/A |
Seq Impedance Zero (µΩ/feet) N/A |
Ampacity LF=100% (A) N/A |
Ampacity LF=75% (A) N/A |
Conductor Size (AWG or kcmil) N/A |
Neutral Wires N/A |
Neutral Size (AWG) N/A |
Conductor Resistance @ 20º C (Ω / 1000 ft) N/A |
Capacitance (μF / 1000 ft) N/A |
Short-Circuit Current - Conductor - 8 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 8 Cycles - (A) N/A |
Short-Circuit Current - Conductor - 16 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 16 Cycles - (A) N/A |
Short-Circuit Current - Conductor - 24 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 24 Cycles - (A) N/A |
A4-04MC4 |
Size of Cable N/A 4-4-4-4+4 |
Phase Conductor Size AWG/MCM N/A 4 |
Number of Phase Conductors N/A 4 |
Diameter of Conductor (mils) N/A 213 |
Thickness of Conductor Insulation (mils) N/A 45 |
Size of Ground Conductor AWG/MCM N/A 4 |
Diameter of Ground (mils) N/A 213 |
Thickness of Ground Insulation (mils) N/A 45 |
Cabling Diameter (mils) N/A 819 |
Overall Diameter of Cable Over Armour (mils) N/A 1093 |
AL Weight (lb/mft) N/A 332 |
Cable Weight (lb/mft) N/A 429 |
Conductor Size AWG or kcmil N/A |
Neutral Wires N/A |
Neutral Size AWG N/A |
Neutral Size N/A |
Sequence Impedance Pos/Neg (µΩ/feet) N/A |
Seq Impedance Zero (µΩ/feet) N/A |
Ampacity LF=100% (A) N/A |
Ampacity LF=75% (A) N/A |
Conductor Size (AWG or kcmil) N/A |
Neutral Wires N/A |
Neutral Size (AWG) N/A |
Conductor Resistance @ 20º C (Ω / 1000 ft) N/A |
Capacitance (μF / 1000 ft) N/A |
Short-Circuit Current - Conductor - 8 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 8 Cycles - (A) N/A |
Short-Circuit Current - Conductor - 16 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 16 Cycles - (A) N/A |
Short-Circuit Current - Conductor - 24 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 24 Cycles - (A) N/A |
A3-04MC6 |
Size of Cable N/A 3-3-3-3+6 |
Phase Conductor Size AWG/MCM N/A 3 |
Number of Phase Conductors N/A 4 |
Diameter of Conductor (mils) N/A 238 |
Thickness of Conductor Insulation (mils) N/A 45 |
Size of Ground Conductor AWG/MCM N/A 6 |
Diameter of Ground (mils) N/A 169 |
Thickness of Ground Insulation (mils) N/A 45 |
Cabling Diameter (mils) N/A 854 |
Overall Diameter of Cable Over Armour (mils) N/A 1128 |
AL Weight (lb/mft) N/A 363 |
Cable Weight (lb/mft) N/A 464 |
Conductor Size AWG or kcmil N/A |
Neutral Wires N/A |
Neutral Size AWG N/A |
Neutral Size N/A |
Sequence Impedance Pos/Neg (µΩ/feet) N/A |
Seq Impedance Zero (µΩ/feet) N/A |
Ampacity LF=100% (A) N/A |
Ampacity LF=75% (A) N/A |
Conductor Size (AWG or kcmil) N/A |
Neutral Wires N/A |
Neutral Size (AWG) N/A |
Conductor Resistance @ 20º C (Ω / 1000 ft) N/A |
Capacitance (μF / 1000 ft) N/A |
Short-Circuit Current - Conductor - 8 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 8 Cycles - (A) N/A |
Short-Circuit Current - Conductor - 16 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 16 Cycles - (A) N/A |
Short-Circuit Current - Conductor - 24 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 24 Cycles - (A) N/A |
A3-04MC4 |
Size of Cable N/A 3-3-3-3+4 |
Phase Conductor Size AWG/MCM N/A 3 |
Number of Phase Conductors N/A 4 |
Diameter of Conductor (mils) N/A 238 |
Thickness of Conductor Insulation (mils) N/A 45 |
Size of Ground Conductor AWG/MCM N/A 4 |
Diameter of Ground (mils) N/A 213 |
Thickness of Ground Insulation (mils) N/A 45 |
Cabling Diameter (mils) N/A 886 |
Overall Diameter of Cable Over Armour (mils) N/A 1159 |
AL Weight (lb/mft) N/A 382 |
Cable Weight (lb/mft) N/A 487 |
Conductor Size AWG or kcmil N/A |
Neutral Wires N/A |
Neutral Size AWG N/A |
Neutral Size N/A |
Sequence Impedance Pos/Neg (µΩ/feet) N/A |
Seq Impedance Zero (µΩ/feet) N/A |
Ampacity LF=100% (A) N/A |
Ampacity LF=75% (A) N/A |
Conductor Size (AWG or kcmil) N/A |
Neutral Wires N/A |
Neutral Size (AWG) N/A |
Conductor Resistance @ 20º C (Ω / 1000 ft) N/A |
Capacitance (μF / 1000 ft) N/A |
Short-Circuit Current - Conductor - 8 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 8 Cycles - (A) N/A |
Short-Circuit Current - Conductor - 16 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 16 Cycles - (A) N/A |
Short-Circuit Current - Conductor - 24 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 24 Cycles - (A) N/A |
A3-04MC3 |
Size of Cable N/A 3-3-3-3+3 |
Phase Conductor Size AWG/MCM N/A 3 |
Number of Phase Conductors N/A 4 |
Diameter of Conductor (mils) N/A 238 |
Thickness of Conductor Insulation (mils) N/A 45 |
Size of Ground Conductor AWG/MCM N/A 3 |
Diameter of Ground (mils) N/A 238 |
Thickness of Ground Insulation (mils) N/A 45 |
Cabling Diameter (mils) N/A 886 |
Overall Diameter of Cable Over Armour (mils) N/A 1159 |
AL Weight (lb/mft) N/A 392 |
Cable Weight (lb/mft) N/A 498 |
Conductor Size AWG or kcmil N/A |
Neutral Wires N/A |
Neutral Size AWG N/A |
Neutral Size N/A |
Sequence Impedance Pos/Neg (µΩ/feet) N/A |
Seq Impedance Zero (µΩ/feet) N/A |
Ampacity LF=100% (A) N/A |
Ampacity LF=75% (A) N/A |
Conductor Size (AWG or kcmil) N/A |
Neutral Wires N/A |
Neutral Size (AWG) N/A |
Conductor Resistance @ 20º C (Ω / 1000 ft) N/A |
Capacitance (μF / 1000 ft) N/A |
Short-Circuit Current - Conductor - 8 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 8 Cycles - (A) N/A |
Short-Circuit Current - Conductor - 16 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 16 Cycles - (A) N/A |
Short-Circuit Current - Conductor - 24 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 24 Cycles - (A) N/A |
A2-04MC6 |
Size of Cable N/A 2-2-2-2+6 |
Phase Conductor Size AWG/MCM N/A 2 |
Number of Phase Conductors N/A 4 |
Diameter of Conductor (mils) N/A 268 |
Thickness of Conductor Insulation (mils) N/A 45 |
Size of Ground Conductor AWG/MCM N/A 6 |
Diameter of Ground (mils) N/A 169 |
Thickness of Ground Insulation (mils) N/A 45 |
Cabling Diameter (mils) N/A 929 |
Overall Diameter of Cable Over Armour (mils) N/A 1203 |
AL Weight (lb/mft) N/A 425 |
Cable Weight (lb/mft) N/A 535 |
Conductor Size AWG or kcmil N/A |
Neutral Wires N/A |
Neutral Size AWG N/A |
Neutral Size N/A |
Sequence Impedance Pos/Neg (µΩ/feet) N/A |
Seq Impedance Zero (µΩ/feet) N/A |
Ampacity LF=100% (A) N/A |
Ampacity LF=75% (A) N/A |
Conductor Size (AWG or kcmil) N/A |
Neutral Wires N/A |
Neutral Size (AWG) N/A |
Conductor Resistance @ 20º C (Ω / 1000 ft) N/A |
Capacitance (μF / 1000 ft) N/A |
Short-Circuit Current - Conductor - 8 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 8 Cycles - (A) N/A |
Short-Circuit Current - Conductor - 16 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 16 Cycles - (A) N/A |
Short-Circuit Current - Conductor - 24 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 24 Cycles - (A) N/A |
A2-04MC4 |
Size of Cable N/A 2-2-2-2+4 |
Phase Conductor Size AWG/MCM N/A 2 |
Number of Phase Conductors N/A 4 |
Diameter of Conductor (mils) N/A 268 |
Thickness of Conductor Insulation (mils) N/A 45 |
Size of Ground Conductor AWG/MCM N/A 4 |
Diameter of Ground (mils) N/A 213 |
Thickness of Ground Insulation (mils) N/A 45 |
Cabling Diameter (mils) N/A 949 |
Overall Diameter of Cable Over Armour (mils) N/A 1222 |
AL Weight (lb/mft) N/A 442 |
Cable Weight (lb/mft) N/A 555 |
Conductor Size AWG or kcmil N/A |
Neutral Wires N/A |
Neutral Size AWG N/A |
Neutral Size N/A |
Sequence Impedance Pos/Neg (µΩ/feet) N/A |
Seq Impedance Zero (µΩ/feet) N/A |
Ampacity LF=100% (A) N/A |
Ampacity LF=75% (A) N/A |
Conductor Size (AWG or kcmil) N/A |
Neutral Wires N/A |
Neutral Size (AWG) N/A |
Conductor Resistance @ 20º C (Ω / 1000 ft) N/A |
Capacitance (μF / 1000 ft) N/A |
Short-Circuit Current - Conductor - 8 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 8 Cycles - (A) N/A |
Short-Circuit Current - Conductor - 16 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 16 Cycles - (A) N/A |
Short-Circuit Current - Conductor - 24 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 24 Cycles - (A) N/A |
A2-04MC2 |
Size of Cable N/A 2-2-2-2+2 |
Phase Conductor Size AWG/MCM N/A 2 |
Number of Phase Conductors N/A 4 |
Diameter of Conductor (mils) N/A 268 |
Thickness of Conductor Insulation (mils) N/A 45 |
Size of Ground Conductor AWG/MCM N/A 2 |
Diameter of Ground (mils) N/A 268 |
Thickness of Ground Insulation (mils) N/A 45 |
Cabling Diameter (mils) N/A 965 |
Overall Diameter of Cable Over Armour (mils) N/A 1238 |
AL Weight (lb/mft) N/A 467 |
Cable Weight (lb/mft) N/A 584 |
Conductor Size AWG or kcmil N/A |
Neutral Wires N/A |
Neutral Size AWG N/A |
Neutral Size N/A |
Sequence Impedance Pos/Neg (µΩ/feet) N/A |
Seq Impedance Zero (µΩ/feet) N/A |
Ampacity LF=100% (A) N/A |
Ampacity LF=75% (A) N/A |
Conductor Size (AWG or kcmil) N/A |
Neutral Wires N/A |
Neutral Size (AWG) N/A |
Conductor Resistance @ 20º C (Ω / 1000 ft) N/A |
Capacitance (μF / 1000 ft) N/A |
Short-Circuit Current - Conductor - 8 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 8 Cycles - (A) N/A |
Short-Circuit Current - Conductor - 16 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 16 Cycles - (A) N/A |
Short-Circuit Current - Conductor - 24 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 24 Cycles - (A) N/A |
A1-04MC4 |
Size of Cable N/A 1-1-1-1+4 |
Phase Conductor Size AWG/MCM N/A 1 |
Number of Phase Conductors N/A 4 |
Diameter of Conductor (mils) N/A 299 |
Thickness of Conductor Insulation (mils) N/A 55 |
Size of Ground Conductor AWG/MCM N/A 4 |
Diameter of Ground (mils) N/A 213 |
Thickness of Ground Insulation (mils) N/A 45 |
Cabling Diameter (mils) N/A 1063 |
Overall Diameter of Cable Over Armour (mils) N/A 1337 |
AL Weight (lb/mft) N/A 524 |
Cable Weight (lb/mft) N/A 672 |
Conductor Size AWG or kcmil N/A |
Neutral Wires N/A |
Neutral Size AWG N/A |
Neutral Size N/A |
Sequence Impedance Pos/Neg (µΩ/feet) N/A |
Seq Impedance Zero (µΩ/feet) N/A |
Ampacity LF=100% (A) N/A |
Ampacity LF=75% (A) N/A |
Conductor Size (AWG or kcmil) N/A |
Neutral Wires N/A |
Neutral Size (AWG) N/A |
Conductor Resistance @ 20º C (Ω / 1000 ft) N/A |
Capacitance (μF / 1000 ft) N/A |
Short-Circuit Current - Conductor - 8 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 8 Cycles - (A) N/A |
Short-Circuit Current - Conductor - 16 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 16 Cycles - (A) N/A |
Short-Circuit Current - Conductor - 24 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 24 Cycles - (A) N/A |
A1-04MC3 |
Size of Cable N/A 1-1-1-1+3 |
Phase Conductor Size AWG/MCM N/A 1 |
Number of Phase Conductors N/A 4 |
Diameter of Conductor (mils) N/A 299 |
Thickness of Conductor Insulation (mils) N/A 55 |
Size of Ground Conductor AWG/MCM N/A 3 |
Diameter of Ground (mils) N/A 238 |
Thickness of Ground Insulation (mils) N/A 45 |
Cabling Diameter (mils) N/A 1083 |
Overall Diameter of Cable Over Armour (mils) N/A 1356 |
AL Weight (lb/mft) N/A 537 |
Cable Weight (lb/mft) N/A 687 |
Conductor Size AWG or kcmil N/A |
Neutral Wires N/A |
Neutral Size AWG N/A |
Neutral Size N/A |
Sequence Impedance Pos/Neg (µΩ/feet) N/A |
Seq Impedance Zero (µΩ/feet) N/A |
Ampacity LF=100% (A) N/A |
Ampacity LF=75% (A) N/A |
Conductor Size (AWG or kcmil) N/A |
Neutral Wires N/A |
Neutral Size (AWG) N/A |
Conductor Resistance @ 20º C (Ω / 1000 ft) N/A |
Capacitance (μF / 1000 ft) N/A |
Short-Circuit Current - Conductor - 8 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 8 Cycles - (A) N/A |
Short-Circuit Current - Conductor - 16 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 16 Cycles - (A) N/A |
Short-Circuit Current - Conductor - 24 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 24 Cycles - (A) N/A |
A1-04MC2 |
Size of Cable N/A 1-1-1-1+2 |
Phase Conductor Size AWG/MCM N/A 1 |
Number of Phase Conductors N/A 4 |
Diameter of Conductor (mils) N/A 299 |
Thickness of Conductor Insulation (mils) N/A 55 |
Size of Ground Conductor AWG/MCM N/A 2 |
Diameter of Ground (mils) N/A 268 |
Thickness of Ground Insulation (mils) N/A 45 |
Cabling Diameter (mils) N/A 1083 |
Overall Diameter of Cable Over Armour (mils) N/A 1356 |
AL Weight (lb/mft) N/A 550 |
Cable Weight (lb/mft) N/A 701 |
Conductor Size AWG or kcmil N/A |
Neutral Wires N/A |
Neutral Size AWG N/A |
Neutral Size N/A |
Sequence Impedance Pos/Neg (µΩ/feet) N/A |
Seq Impedance Zero (µΩ/feet) N/A |
Ampacity LF=100% (A) N/A |
Ampacity LF=75% (A) N/A |
Conductor Size (AWG or kcmil) N/A |
Neutral Wires N/A |
Neutral Size (AWG) N/A |
Conductor Resistance @ 20º C (Ω / 1000 ft) N/A |
Capacitance (μF / 1000 ft) N/A |
Short-Circuit Current - Conductor - 8 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 8 Cycles - (A) N/A |
Short-Circuit Current - Conductor - 16 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 16 Cycles - (A) N/A |
Short-Circuit Current - Conductor - 24 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 24 Cycles - (A) N/A |
A1-04MC1 |
Size of Cable N/A 1-1-1-1+1 |
Phase Conductor Size AWG/MCM N/A 1 |
Number of Phase Conductors N/A 4 |
Diameter of Conductor (mils) N/A 299 |
Thickness of Conductor Insulation (mils) N/A 55 |
Size of Ground Conductor AWG/MCM N/A 1 |
Diameter of Ground (mils) N/A 299 |
Thickness of Ground Insulation (mils) N/A 55 |
Cabling Diameter (mils) N/A 1106 |
Overall Diameter of Cable Over Armour (mils) N/A 1380 |
AL Weight (lb/mft) N/A 569 |
Cable Weight (lb/mft) N/A 730 |
Conductor Size AWG or kcmil N/A |
Neutral Wires N/A |
Neutral Size AWG N/A |
Neutral Size N/A |
Sequence Impedance Pos/Neg (µΩ/feet) N/A |
Seq Impedance Zero (µΩ/feet) N/A |
Ampacity LF=100% (A) N/A |
Ampacity LF=75% (A) N/A |
Conductor Size (AWG or kcmil) N/A |
Neutral Wires N/A |
Neutral Size (AWG) N/A |
Conductor Resistance @ 20º C (Ω / 1000 ft) N/A |
Capacitance (μF / 1000 ft) N/A |
Short-Circuit Current - Conductor - 8 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 8 Cycles - (A) N/A |
Short-Circuit Current - Conductor - 16 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 16 Cycles - (A) N/A |
Short-Circuit Current - Conductor - 24 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 24 Cycles - (A) N/A |
A1/0-04MC4 |
Size of Cable N/A 1/0-1/0-1/0-1/0+4 |
Phase Conductor Size AWG/MCM N/A 1/0 |
Number of Phase Conductors N/A 4 |
Diameter of Conductor (mils) N/A 336 |
Thickness of Conductor Insulation (mils) N/A 55 |
Size of Ground Conductor AWG/MCM N/A 4 |
Diameter of Ground (mils) N/A 213 |
Thickness of Ground Insulation (mils) N/A 45 |
Cabling Diameter (mils) N/A 1138 |
Overall Diameter of Cable Over Armour (mils) N/A 1411 |
AL Weight (lb/mft) N/A 617 |
Cable Weight (lb/mft) N/A 778 |
Conductor Size AWG or kcmil N/A |
Neutral Wires N/A |
Neutral Size AWG N/A |
Neutral Size N/A |
Sequence Impedance Pos/Neg (µΩ/feet) N/A |
Seq Impedance Zero (µΩ/feet) N/A |
Ampacity LF=100% (A) N/A |
Ampacity LF=75% (A) N/A |
Conductor Size (AWG or kcmil) N/A |
Neutral Wires N/A |
Neutral Size (AWG) N/A |
Conductor Resistance @ 20º C (Ω / 1000 ft) N/A |
Capacitance (μF / 1000 ft) N/A |
Short-Circuit Current - Conductor - 8 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 8 Cycles - (A) N/A |
Short-Circuit Current - Conductor - 16 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 16 Cycles - (A) N/A |
Short-Circuit Current - Conductor - 24 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 24 Cycles - (A) N/A |
A1/0-04MC3 |
Size of Cable N/A 1/0-1/0-1/0-1/0+3 |
Phase Conductor Size AWG/MCM N/A 1/0 |
Number of Phase Conductors N/A 4 |
Diameter of Conductor (mils) N/A 336 |
Thickness of Conductor Insulation (mils) N/A 55 |
Size of Ground Conductor AWG/MCM N/A 3 |
Diameter of Ground (mils) N/A 238 |
Thickness of Ground Insulation (mils) N/A 45 |
Cabling Diameter (mils) N/A 1161 |
Overall Diameter of Cable Over Armour (mils) N/A 1435 |
AL Weight (lb/mft) N/A 631 |
Cable Weight (lb/mft) N/A 794 |
Conductor Size AWG or kcmil N/A |
Neutral Wires N/A |
Neutral Size AWG N/A |
Neutral Size N/A |
Sequence Impedance Pos/Neg (µΩ/feet) N/A |
Seq Impedance Zero (µΩ/feet) N/A |
Ampacity LF=100% (A) N/A |
Ampacity LF=75% (A) N/A |
Conductor Size (AWG or kcmil) N/A |
Neutral Wires N/A |
Neutral Size (AWG) N/A |
Conductor Resistance @ 20º C (Ω / 1000 ft) N/A |
Capacitance (μF / 1000 ft) N/A |
Short-Circuit Current - Conductor - 8 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 8 Cycles - (A) N/A |
Short-Circuit Current - Conductor - 16 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 16 Cycles - (A) N/A |
Short-Circuit Current - Conductor - 24 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 24 Cycles - (A) N/A |
A1/0-04MC2 |
Size of Cable N/A 1/0-1/0-1/0-1/0+2 |
Phase Conductor Size AWG/MCM N/A 1/0 |
Number of Phase Conductors N/A 4 |
Diameter of Conductor (mils) N/A 336 |
Thickness of Conductor Insulation (mils) N/A 55 |
Size of Ground Conductor AWG/MCM N/A 2 |
Diameter of Ground (mils) N/A 268 |
Thickness of Ground Insulation (mils) N/A 45 |
Cabling Diameter (mils) N/A 1181 |
Overall Diameter of Cable Over Armour (mils) N/A 1455 |
AL Weight (lb/mft) N/A 647 |
Cable Weight (lb/mft) N/A 812 |
Conductor Size AWG or kcmil N/A |
Neutral Wires N/A |
Neutral Size AWG N/A |
Neutral Size N/A |
Sequence Impedance Pos/Neg (µΩ/feet) N/A |
Seq Impedance Zero (µΩ/feet) N/A |
Ampacity LF=100% (A) N/A |
Ampacity LF=75% (A) N/A |
Conductor Size (AWG or kcmil) N/A |
Neutral Wires N/A |
Neutral Size (AWG) N/A |
Conductor Resistance @ 20º C (Ω / 1000 ft) N/A |
Capacitance (μF / 1000 ft) N/A |
Short-Circuit Current - Conductor - 8 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 8 Cycles - (A) N/A |
Short-Circuit Current - Conductor - 16 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 16 Cycles - (A) N/A |
Short-Circuit Current - Conductor - 24 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 24 Cycles - (A) N/A |
A1/0-04MC1 |
Size of Cable N/A 1/0-1/0-1/0-1/0+1 |
Phase Conductor Size AWG/MCM N/A 1/0 |
Number of Phase Conductors N/A 4 |
Diameter of Conductor (mils) N/A 336 |
Thickness of Conductor Insulation (mils) N/A 55 |
Size of Ground Conductor AWG/MCM N/A 1 |
Diameter of Ground (mils) N/A 299 |
Thickness of Ground Insulation (mils) N/A 55 |
Cabling Diameter (mils) N/A 1205 |
Overall Diameter of Cable Over Armour (mils) N/A 1478 |
AL Weight (lb/mft) N/A 666 |
Cable Weight (lb/mft) N/A 840 |
Conductor Size AWG or kcmil N/A |
Neutral Wires N/A |
Neutral Size AWG N/A |
Neutral Size N/A |
Sequence Impedance Pos/Neg (µΩ/feet) N/A |
Seq Impedance Zero (µΩ/feet) N/A |
Ampacity LF=100% (A) N/A |
Ampacity LF=75% (A) N/A |
Conductor Size (AWG or kcmil) N/A |
Neutral Wires N/A |
Neutral Size (AWG) N/A |
Conductor Resistance @ 20º C (Ω / 1000 ft) N/A |
Capacitance (μF / 1000 ft) N/A |
Short-Circuit Current - Conductor - 8 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 8 Cycles - (A) N/A |
Short-Circuit Current - Conductor - 16 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 16 Cycles - (A) N/A |
Short-Circuit Current - Conductor - 24 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 24 Cycles - (A) N/A |
A1/0-04MC1/0 |
Size of Cable N/A 1/0-1/0-1/0-1/0+1/0 |
Phase Conductor Size AWG/MCM N/A 1/0 |
Number of Phase Conductors N/A 4 |
Diameter of Conductor (mils) N/A 336 |
Thickness of Conductor Insulation (mils) N/A 55 |
Size of Ground Conductor AWG/MCM N/A 1/0 |
Diameter of Ground (mils) N/A 336 |
Thickness of Ground Insulation (mils) N/A 55 |
Cabling Diameter (mils) N/A 1205 |
Overall Diameter of Cable Over Armour (mils) N/A 1478 |
AL Weight (lb/mft) N/A 686 |
Cable Weight (lb/mft) N/A 863 |
Conductor Size AWG or kcmil N/A |
Neutral Wires N/A |
Neutral Size AWG N/A |
Neutral Size N/A |
Sequence Impedance Pos/Neg (µΩ/feet) N/A |
Seq Impedance Zero (µΩ/feet) N/A |
Ampacity LF=100% (A) N/A |
Ampacity LF=75% (A) N/A |
Conductor Size (AWG or kcmil) N/A |
Neutral Wires N/A |
Neutral Size (AWG) N/A |
Conductor Resistance @ 20º C (Ω / 1000 ft) N/A |
Capacitance (μF / 1000 ft) N/A |
Short-Circuit Current - Conductor - 8 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 8 Cycles - (A) N/A |
Short-Circuit Current - Conductor - 16 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 16 Cycles - (A) N/A |
Short-Circuit Current - Conductor - 24 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 24 Cycles - (A) N/A |
A2/0-04MC4 |
Size of Cable N/A 2/0-2/0-2/0-2/0+4 |
Phase Conductor Size AWG/MCM N/A 2/0 |
Number of Phase Conductors N/A 4 |
Diameter of Conductor (mils) N/A 376 |
Thickness of Conductor Insulation (mils) N/A 55 |
Size of Ground Conductor AWG/MCM N/A 4 |
Diameter of Ground (mils) N/A 213 |
Thickness of Ground Insulation (mils) N/A 45 |
Cabling Diameter (mils) N/A 1240 |
Overall Diameter of Cable Over Armour (mils) N/A 1514 |
AL Weight (lb/mft) N/A 733 |
Cable Weight (lb/mft) N/A 909 |
Conductor Size AWG or kcmil N/A |
Neutral Wires N/A |
Neutral Size AWG N/A |
Neutral Size N/A |
Sequence Impedance Pos/Neg (µΩ/feet) N/A |
Seq Impedance Zero (µΩ/feet) N/A |
Ampacity LF=100% (A) N/A |
Ampacity LF=75% (A) N/A |
Conductor Size (AWG or kcmil) N/A |
Neutral Wires N/A |
Neutral Size (AWG) N/A |
Conductor Resistance @ 20º C (Ω / 1000 ft) N/A |
Capacitance (μF / 1000 ft) N/A |
Short-Circuit Current - Conductor - 8 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 8 Cycles - (A) N/A |
Short-Circuit Current - Conductor - 16 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 16 Cycles - (A) N/A |
Short-Circuit Current - Conductor - 24 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 24 Cycles - (A) N/A |
A2/0-04MC2 |
Size of Cable N/A 2/0-2/0-2/0-2/0+2 |
Phase Conductor Size AWG/MCM N/A 2/0 |
Number of Phase Conductors N/A 4 |
Diameter of Conductor (mils) N/A 376 |
Thickness of Conductor Insulation (mils) N/A 55 |
Size of Ground Conductor AWG/MCM N/A 2 |
Diameter of Ground (mils) N/A 268 |
Thickness of Ground Insulation (mils) N/A 45 |
Cabling Diameter (mils) N/A 1264 |
Overall Diameter of Cable Over Armour (mils) N/A 1537 |
AL Weight (lb/mft) N/A 760 |
Cable Weight (lb/mft) N/A 939 |
Conductor Size AWG or kcmil N/A |
Neutral Wires N/A |
Neutral Size AWG N/A |
Neutral Size N/A |
Sequence Impedance Pos/Neg (µΩ/feet) N/A |
Seq Impedance Zero (µΩ/feet) N/A |
Ampacity LF=100% (A) N/A |
Ampacity LF=75% (A) N/A |
Conductor Size (AWG or kcmil) N/A |
Neutral Wires N/A |
Neutral Size (AWG) N/A |
Conductor Resistance @ 20º C (Ω / 1000 ft) N/A |
Capacitance (μF / 1000 ft) N/A |
Short-Circuit Current - Conductor - 8 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 8 Cycles - (A) N/A |
Short-Circuit Current - Conductor - 16 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 16 Cycles - (A) N/A |
Short-Circuit Current - Conductor - 24 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 24 Cycles - (A) N/A |
A2/0-04MC1 |
Size of Cable N/A 2/0-2/0-2/0-2/0+1 |
Phase Conductor Size AWG/MCM N/A 2/0 |
Number of Phase Conductors N/A 4 |
Diameter of Conductor (mils) N/A 376 |
Thickness of Conductor Insulation (mils) N/A 55 |
Size of Ground Conductor AWG/MCM N/A 1 |
Diameter of Ground (mils) N/A 299 |
Thickness of Ground Insulation (mils) N/A 55 |
Cabling Diameter (mils) N/A 1287 |
Overall Diameter of Cable Over Armour (mils) N/A 1561 |
AL Weight (lb/mft) N/A 779 |
Cable Weight (lb/mft) N/A 968 |
Conductor Size AWG or kcmil N/A |
Neutral Wires N/A |
Neutral Size AWG N/A |
Neutral Size N/A |
Sequence Impedance Pos/Neg (µΩ/feet) N/A |
Seq Impedance Zero (µΩ/feet) N/A |
Ampacity LF=100% (A) N/A |
Ampacity LF=75% (A) N/A |
Conductor Size (AWG or kcmil) N/A |
Neutral Wires N/A |
Neutral Size (AWG) N/A |
Conductor Resistance @ 20º C (Ω / 1000 ft) N/A |
Capacitance (μF / 1000 ft) N/A |
Short-Circuit Current - Conductor - 8 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 8 Cycles - (A) N/A |
Short-Circuit Current - Conductor - 16 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 16 Cycles - (A) N/A |
Short-Circuit Current - Conductor - 24 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 24 Cycles - (A) N/A |
A2/0-04MC1/0 |
Size of Cable N/A 2/0-2/0-2/0-2/0+1/0 |
Phase Conductor Size AWG/MCM N/A 2/0 |
Number of Phase Conductors N/A 4 |
Diameter of Conductor (mils) N/A 376 |
Thickness of Conductor Insulation (mils) N/A 55 |
Size of Ground Conductor AWG/MCM N/A 1/0 |
Diameter of Ground (mils) N/A 336 |
Thickness of Ground Insulation (mils) N/A 55 |
Cabling Diameter (mils) N/A 1311 |
Overall Diameter of Cable Over Armour (mils) N/A 1585 |
AL Weight (lb/mft) N/A 803 |
Cable Weight (lb/mft) N/A 995 |
Conductor Size AWG or kcmil N/A |
Neutral Wires N/A |
Neutral Size AWG N/A |
Neutral Size N/A |
Sequence Impedance Pos/Neg (µΩ/feet) N/A |
Seq Impedance Zero (µΩ/feet) N/A |
Ampacity LF=100% (A) N/A |
Ampacity LF=75% (A) N/A |
Conductor Size (AWG or kcmil) N/A |
Neutral Wires N/A |
Neutral Size (AWG) N/A |
Conductor Resistance @ 20º C (Ω / 1000 ft) N/A |
Capacitance (μF / 1000 ft) N/A |
Short-Circuit Current - Conductor - 8 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 8 Cycles - (A) N/A |
Short-Circuit Current - Conductor - 16 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 16 Cycles - (A) N/A |
Short-Circuit Current - Conductor - 24 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 24 Cycles - (A) N/A |
A2/0-04MC2/0 |
Size of Cable N/A 2/0-2/0-2/0-2/0+2/0 |
Phase Conductor Size AWG/MCM N/A 2/0 |
Number of Phase Conductors N/A 4 |
Diameter of Conductor (mils) N/A 376 |
Thickness of Conductor Insulation (mils) N/A 55 |
Size of Ground Conductor AWG/MCM N/A 2/0 |
Diameter of Ground (mils) N/A 376 |
Thickness of Ground Insulation (mils) N/A 55 |
Cabling Diameter (mils) N/A 1311 |
Overall Diameter of Cable Over Armour (mils) N/A 1585 |
AL Weight (lb/mft) N/A 828 |
Cable Weight (lb/mft) N/A 1023 |
Conductor Size AWG or kcmil N/A |
Neutral Wires N/A |
Neutral Size AWG N/A |
Neutral Size N/A |
Sequence Impedance Pos/Neg (µΩ/feet) N/A |
Seq Impedance Zero (µΩ/feet) N/A |
Ampacity LF=100% (A) N/A |
Ampacity LF=75% (A) N/A |
Conductor Size (AWG or kcmil) N/A |
Neutral Wires N/A |
Neutral Size (AWG) N/A |
Conductor Resistance @ 20º C (Ω / 1000 ft) N/A |
Capacitance (μF / 1000 ft) N/A |
Short-Circuit Current - Conductor - 8 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 8 Cycles - (A) N/A |
Short-Circuit Current - Conductor - 16 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 16 Cycles - (A) N/A |
Short-Circuit Current - Conductor - 24 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 24 Cycles - (A) N/A |
A3/0-04MC4 |
Size of Cable N/A 3/0-3/0-3/0-3/0+4 |
Phase Conductor Size AWG/MCM N/A 3/0 |
Number of Phase Conductors N/A 4 |
Diameter of Conductor (mils) N/A 421 |
Thickness of Conductor Insulation (mils) N/A 55 |
Size of Ground Conductor AWG/MCM N/A 4 |
Diameter of Ground (mils) N/A 213 |
Thickness of Ground Insulation (mils) N/A 45 |
Cabling Diameter (mils) N/A 1327 |
Overall Diameter of Cable Over Armour (mils) N/A 1600 |
AL Weight (lb/mft) N/A 875 |
Cable Weight (lb/mft) N/A 1066 |
Conductor Size AWG or kcmil N/A |
Neutral Wires N/A |
Neutral Size AWG N/A |
Neutral Size N/A |
Sequence Impedance Pos/Neg (µΩ/feet) N/A |
Seq Impedance Zero (µΩ/feet) N/A |
Ampacity LF=100% (A) N/A |
Ampacity LF=75% (A) N/A |
Conductor Size (AWG or kcmil) N/A |
Neutral Wires N/A |
Neutral Size (AWG) N/A |
Conductor Resistance @ 20º C (Ω / 1000 ft) N/A |
Capacitance (μF / 1000 ft) N/A |
Short-Circuit Current - Conductor - 8 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 8 Cycles - (A) N/A |
Short-Circuit Current - Conductor - 16 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 16 Cycles - (A) N/A |
Short-Circuit Current - Conductor - 24 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 24 Cycles - (A) N/A |
A3/0-04MC2 |
Size of Cable N/A 3/0-3/0-3/0-3/0+2 |
Phase Conductor Size AWG/MCM N/A 3/0 |
Number of Phase Conductors N/A 4 |
Diameter of Conductor (mils) N/A 421 |
Thickness of Conductor Insulation (mils) N/A 55 |
Size of Ground Conductor AWG/MCM N/A 2 |
Diameter of Ground (mils) N/A 268 |
Thickness of Ground Insulation (mils) N/A 45 |
Cabling Diameter (mils) N/A 1354 |
Overall Diameter of Cable Over Armour (mils) N/A 1628 |
AL Weight (lb/mft) N/A 902 |
Cable Weight (lb/mft) N/A 1097 |
Conductor Size AWG or kcmil N/A |
Neutral Wires N/A |
Neutral Size AWG N/A |
Neutral Size N/A |
Sequence Impedance Pos/Neg (µΩ/feet) N/A |
Seq Impedance Zero (µΩ/feet) N/A |
Ampacity LF=100% (A) N/A |
Ampacity LF=75% (A) N/A |
Conductor Size (AWG or kcmil) N/A |
Neutral Wires N/A |
Neutral Size (AWG) N/A |
Conductor Resistance @ 20º C (Ω / 1000 ft) N/A |
Capacitance (μF / 1000 ft) N/A |
Short-Circuit Current - Conductor - 8 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 8 Cycles - (A) N/A |
Short-Circuit Current - Conductor - 16 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 16 Cycles - (A) N/A |
Short-Circuit Current - Conductor - 24 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 24 Cycles - (A) N/A |
A3/0-04MC1 |
Size of Cable N/A 3/0-3/0-3/0-3/0+1 |
Phase Conductor Size AWG/MCM N/A 3/0 |
Number of Phase Conductors N/A 4 |
Diameter of Conductor (mils) N/A 421 |
Thickness of Conductor Insulation (mils) N/A 55 |
Size of Ground Conductor AWG/MCM N/A 1 |
Diameter of Ground (mils) N/A 299 |
Thickness of Ground Insulation (mils) N/A 55 |
Cabling Diameter (mils) N/A 1382 |
Overall Diameter of Cable Over Armour (mils) N/A 1656 |
AL Weight (lb/mft) N/A 922 |
Cable Weight (lb/mft) N/A 1126 |
Conductor Size AWG or kcmil N/A |
Neutral Wires N/A |
Neutral Size AWG N/A |
Neutral Size N/A |
Sequence Impedance Pos/Neg (µΩ/feet) N/A |
Seq Impedance Zero (µΩ/feet) N/A |
Ampacity LF=100% (A) N/A |
Ampacity LF=75% (A) N/A |
Conductor Size (AWG or kcmil) N/A |
Neutral Wires N/A |
Neutral Size (AWG) N/A |
Conductor Resistance @ 20º C (Ω / 1000 ft) N/A |
Capacitance (μF / 1000 ft) N/A |
Short-Circuit Current - Conductor - 8 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 8 Cycles - (A) N/A |
Short-Circuit Current - Conductor - 16 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 16 Cycles - (A) N/A |
Short-Circuit Current - Conductor - 24 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 24 Cycles - (A) N/A |
A3/0-04MC1/0 |
Size of Cable N/A 3/0-3/0-3/0-3/0+1/0 |
Phase Conductor Size AWG/MCM N/A 3/0 |
Number of Phase Conductors N/A 4 |
Diameter of Conductor (mils) N/A 421 |
Thickness of Conductor Insulation (mils) N/A 55 |
Size of Ground Conductor AWG/MCM N/A 1/0 |
Diameter of Ground (mils) N/A 336 |
Thickness of Ground Insulation (mils) N/A 55 |
Cabling Diameter (mils) N/A 1406 |
Overall Diameter of Cable Over Armour (mils) N/A 1679 |
AL Weight (lb/mft) N/A 946 |
Cable Weight (lb/mft) N/A 1154 |
Conductor Size AWG or kcmil N/A |
Neutral Wires N/A |
Neutral Size AWG N/A |
Neutral Size N/A |
Sequence Impedance Pos/Neg (µΩ/feet) N/A |
Seq Impedance Zero (µΩ/feet) N/A |
Ampacity LF=100% (A) N/A |
Ampacity LF=75% (A) N/A |
Conductor Size (AWG or kcmil) N/A |
Neutral Wires N/A |
Neutral Size (AWG) N/A |
Conductor Resistance @ 20º C (Ω / 1000 ft) N/A |
Capacitance (μF / 1000 ft) N/A |
Short-Circuit Current - Conductor - 8 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 8 Cycles - (A) N/A |
Short-Circuit Current - Conductor - 16 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 16 Cycles - (A) N/A |
Short-Circuit Current - Conductor - 24 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 24 Cycles - (A) N/A |
A3/0-04MC2/0 |
Size of Cable N/A 3/0-3/0-3/0-3/0+2/0 |
Phase Conductor Size AWG/MCM N/A 3/0 |
Number of Phase Conductors N/A 4 |
Diameter of Conductor (mils) N/A 421 |
Thickness of Conductor Insulation (mils) N/A 55 |
Size of Ground Conductor AWG/MCM N/A 2/0 |
Diameter of Ground (mils) N/A 376 |
Thickness of Ground Insulation (mils) N/A 55 |
Cabling Diameter (mils) N/A 1433 |
Overall Diameter of Cable Over Armour (mils) N/A 1707 |
AL Weight (lb/mft) N/A 975 |
Cable Weight (lb/mft) N/A 1187 |
Conductor Size AWG or kcmil N/A |
Neutral Wires N/A |
Neutral Size AWG N/A |
Neutral Size N/A |
Sequence Impedance Pos/Neg (µΩ/feet) N/A |
Seq Impedance Zero (µΩ/feet) N/A |
Ampacity LF=100% (A) N/A |
Ampacity LF=75% (A) N/A |
Conductor Size (AWG or kcmil) N/A |
Neutral Wires N/A |
Neutral Size (AWG) N/A |
Conductor Resistance @ 20º C (Ω / 1000 ft) N/A |
Capacitance (μF / 1000 ft) N/A |
Short-Circuit Current - Conductor - 8 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 8 Cycles - (A) N/A |
Short-Circuit Current - Conductor - 16 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 16 Cycles - (A) N/A |
Short-Circuit Current - Conductor - 24 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 24 Cycles - (A) N/A |
A3/0-04MC3/0 |
Size of Cable N/A 3/0-3/0-3/0-3/0+3/0 |
Phase Conductor Size AWG/MCM N/A 3/0 |
Number of Phase Conductors N/A 4 |
Diameter of Conductor (mils) N/A 421 |
Thickness of Conductor Insulation (mils) N/A 55 |
Size of Ground Conductor AWG/MCM N/A 3/0 |
Diameter of Ground (mils) N/A 421 |
Thickness of Ground Insulation (mils) N/A 55 |
Cabling Diameter (mils) N/A 1433 |
Overall Diameter of Cable Over Armour (mils) N/A 1707 |
AL Weight (lb/mft) N/A 1007 |
Cable Weight (lb/mft) N/A 1223 |
Conductor Size AWG or kcmil N/A |
Neutral Wires N/A |
Neutral Size AWG N/A |
Neutral Size N/A |
Sequence Impedance Pos/Neg (µΩ/feet) N/A |
Seq Impedance Zero (µΩ/feet) N/A |
Ampacity LF=100% (A) N/A |
Ampacity LF=75% (A) N/A |
Conductor Size (AWG or kcmil) N/A |
Neutral Wires N/A |
Neutral Size (AWG) N/A |
Conductor Resistance @ 20º C (Ω / 1000 ft) N/A |
Capacitance (μF / 1000 ft) N/A |
Short-Circuit Current - Conductor - 8 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 8 Cycles - (A) N/A |
Short-Circuit Current - Conductor - 16 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 16 Cycles - (A) N/A |
Short-Circuit Current - Conductor - 24 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 24 Cycles - (A) N/A |
A4/0-04MC2 |
Size of Cable N/A 4/0-4/0-4/0-4/0+2 |
Phase Conductor Size AWG/MCM N/A 4/0 |
Number of Phase Conductors N/A 4 |
Diameter of Conductor (mils) N/A 476 |
Thickness of Conductor Insulation (mils) N/A 55 |
Size of Ground Conductor AWG/MCM N/A 2 |
Diameter of Ground (mils) N/A 268 |
Thickness of Ground Insulation (mils) N/A 45 |
Cabling Diameter (mils) N/A 1492 |
Overall Diameter of Cable Over Armour (mils) N/A 1816 |
AL Weight (lb/mft) N/A 1134 |
Cable Weight (lb/mft) N/A 1350 |
Conductor Size AWG or kcmil N/A |
Neutral Wires N/A |
Neutral Size AWG N/A |
Neutral Size N/A |
Sequence Impedance Pos/Neg (µΩ/feet) N/A |
Seq Impedance Zero (µΩ/feet) N/A |
Ampacity LF=100% (A) N/A |
Ampacity LF=75% (A) N/A |
Conductor Size (AWG or kcmil) N/A |
Neutral Wires N/A |
Neutral Size (AWG) N/A |
Conductor Resistance @ 20º C (Ω / 1000 ft) N/A |
Capacitance (μF / 1000 ft) N/A |
Short-Circuit Current - Conductor - 8 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 8 Cycles - (A) N/A |
Short-Circuit Current - Conductor - 16 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 16 Cycles - (A) N/A |
Short-Circuit Current - Conductor - 24 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 24 Cycles - (A) N/A |
A4/0-04MC1 |
Size of Cable N/A 4/0-4/0-4/0-4/0+1 |
Phase Conductor Size AWG/MCM N/A 4/0 |
Number of Phase Conductors N/A 4 |
Diameter of Conductor (mils) N/A 476 |
Thickness of Conductor Insulation (mils) N/A 55 |
Size of Ground Conductor AWG/MCM N/A 1 |
Diameter of Ground (mils) N/A 299 |
Thickness of Ground Insulation (mils) N/A 55 |
Cabling Diameter (mils) N/A 1492 |
Overall Diameter of Cable Over Armour (mils) N/A 1816 |
AL Weight (lb/mft) N/A 1150 |
Cable Weight (lb/mft) N/A 1374 |
Conductor Size AWG or kcmil N/A |
Neutral Wires N/A |
Neutral Size AWG N/A |
Neutral Size N/A |
Sequence Impedance Pos/Neg (µΩ/feet) N/A |
Seq Impedance Zero (µΩ/feet) N/A |
Ampacity LF=100% (A) N/A |
Ampacity LF=75% (A) N/A |
Conductor Size (AWG or kcmil) N/A |
Neutral Wires N/A |
Neutral Size (AWG) N/A |
Conductor Resistance @ 20º C (Ω / 1000 ft) N/A |
Capacitance (μF / 1000 ft) N/A |
Short-Circuit Current - Conductor - 8 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 8 Cycles - (A) N/A |
Short-Circuit Current - Conductor - 16 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 16 Cycles - (A) N/A |
Short-Circuit Current - Conductor - 24 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 24 Cycles - (A) N/A |
A4/0-04MC1/0 |
Size of Cable N/A 4/0-4/0-4/0-4/0+1/0 |
Phase Conductor Size AWG/MCM N/A 4/0 |
Number of Phase Conductors N/A 4 |
Diameter of Conductor (mils) N/A 476 |
Thickness of Conductor Insulation (mils) N/A 55 |
Size of Ground Conductor AWG/MCM N/A 1/0 |
Diameter of Ground (mils) N/A 336 |
Thickness of Ground Insulation (mils) N/A 55 |
Cabling Diameter (mils) N/A 1524 |
Overall Diameter of Cable Over Armour (mils) N/A 1847 |
AL Weight (lb/mft) N/A 1176 |
Cable Weight (lb/mft) N/A 1404 |
Conductor Size AWG or kcmil N/A |
Neutral Wires N/A |
Neutral Size AWG N/A |
Neutral Size N/A |
Sequence Impedance Pos/Neg (µΩ/feet) N/A |
Seq Impedance Zero (µΩ/feet) N/A |
Ampacity LF=100% (A) N/A |
Ampacity LF=75% (A) N/A |
Conductor Size (AWG or kcmil) N/A |
Neutral Wires N/A |
Neutral Size (AWG) N/A |
Conductor Resistance @ 20º C (Ω / 1000 ft) N/A |
Capacitance (μF / 1000 ft) N/A |
Short-Circuit Current - Conductor - 8 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 8 Cycles - (A) N/A |
Short-Circuit Current - Conductor - 16 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 16 Cycles - (A) N/A |
Short-Circuit Current - Conductor - 24 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 24 Cycles - (A) N/A |
A4/0-04MC2/0 |
Size of Cable N/A 4/0-4/0-4/0-4/0+2/0 |
Phase Conductor Size AWG/MCM N/A 4/0 |
Number of Phase Conductors N/A 4 |
Diameter of Conductor (mils) N/A 476 |
Thickness of Conductor Insulation (mils) N/A 55 |
Size of Ground Conductor AWG/MCM N/A 2/0 |
Diameter of Ground (mils) N/A 376 |
Thickness of Ground Insulation (mils) N/A 55 |
Cabling Diameter (mils) N/A 1551 |
Overall Diameter of Cable Over Armour (mils) N/A 1875 |
AL Weight (lb/mft) N/A 1206 |
Cable Weight (lb/mft) N/A 1438 |
Conductor Size AWG or kcmil N/A |
Neutral Wires N/A |
Neutral Size AWG N/A |
Neutral Size N/A |
Sequence Impedance Pos/Neg (µΩ/feet) N/A |
Seq Impedance Zero (µΩ/feet) N/A |
Ampacity LF=100% (A) N/A |
Ampacity LF=75% (A) N/A |
Conductor Size (AWG or kcmil) N/A |
Neutral Wires N/A |
Neutral Size (AWG) N/A |
Conductor Resistance @ 20º C (Ω / 1000 ft) N/A |
Capacitance (μF / 1000 ft) N/A |
Short-Circuit Current - Conductor - 8 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 8 Cycles - (A) N/A |
Short-Circuit Current - Conductor - 16 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 16 Cycles - (A) N/A |
Short-Circuit Current - Conductor - 24 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 24 Cycles - (A) N/A |
A4/0-04MC3/0 |
Size of Cable N/A 4/0-4/0-4/0-4/0+3/0 |
Phase Conductor Size AWG/MCM N/A 4/0 |
Number of Phase Conductors N/A 4 |
Diameter of Conductor (mils) N/A 476 |
Thickness of Conductor Insulation (mils) N/A 55 |
Size of Ground Conductor AWG/MCM N/A 3/0 |
Diameter of Ground (mils) N/A 421 |
Thickness of Ground Insulation (mils) N/A 55 |
Cabling Diameter (mils) N/A 1583 |
Overall Diameter of Cable Over Armour (mils) N/A 1906 |
AL Weight (lb/mft) N/A 1244 |
Cable Weight (lb/mft) N/A 1479 |
Conductor Size AWG or kcmil N/A |
Neutral Wires N/A |
Neutral Size AWG N/A |
Neutral Size N/A |
Sequence Impedance Pos/Neg (µΩ/feet) N/A |
Seq Impedance Zero (µΩ/feet) N/A |
Ampacity LF=100% (A) N/A |
Ampacity LF=75% (A) N/A |
Conductor Size (AWG or kcmil) N/A |
Neutral Wires N/A |
Neutral Size (AWG) N/A |
Conductor Resistance @ 20º C (Ω / 1000 ft) N/A |
Capacitance (μF / 1000 ft) N/A |
Short-Circuit Current - Conductor - 8 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 8 Cycles - (A) N/A |
Short-Circuit Current - Conductor - 16 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 16 Cycles - (A) N/A |
Short-Circuit Current - Conductor - 24 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 24 Cycles - (A) N/A |
A4/0-04MC4/0 |
Size of Cable N/A 4/0-4/0-4/0-4/0+4/0 |
Phase Conductor Size AWG/MCM N/A 4/0 |
Number of Phase Conductors N/A 4 |
Diameter of Conductor (mils) N/A 476 |
Thickness of Conductor Insulation (mils) N/A 55 |
Size of Ground Conductor AWG/MCM N/A 4/0 |
Diameter of Ground (mils) N/A 476 |
Thickness of Ground Insulation (mils) N/A 55 |
Cabling Diameter (mils) N/A 1583 |
Overall Diameter of Cable Over Armour (mils) N/A 1906 |
AL Weight (lb/mft) N/A 1284 |
Cable Weight (lb/mft) N/A 1524 |
Conductor Size AWG or kcmil N/A |
Neutral Wires N/A |
Neutral Size AWG N/A |
Neutral Size N/A |
Sequence Impedance Pos/Neg (µΩ/feet) N/A |
Seq Impedance Zero (µΩ/feet) N/A |
Ampacity LF=100% (A) N/A |
Ampacity LF=75% (A) N/A |
Conductor Size (AWG or kcmil) N/A |
Neutral Wires N/A |
Neutral Size (AWG) N/A |
Conductor Resistance @ 20º C (Ω / 1000 ft) N/A |
Capacitance (μF / 1000 ft) N/A |
Short-Circuit Current - Conductor - 8 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 8 Cycles - (A) N/A |
Short-Circuit Current - Conductor - 16 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 16 Cycles - (A) N/A |
Short-Circuit Current - Conductor - 24 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 24 Cycles - (A) N/A |
A250-04MC2 |
Size of Cable N/A 250-250-250-250+2 |
Phase Conductor Size AWG/MCM N/A 250 |
Number of Phase Conductors N/A 4 |
Diameter of Conductor (mils) N/A 520 |
Thickness of Conductor Insulation (mils) N/A 65 |
Size of Ground Conductor AWG/MCM N/A 2 |
Diameter of Ground (mils) N/A 268 |
Thickness of Ground Insulation (mils) N/A 45 |
Cabling Diameter (mils) N/A 1626 |
Overall Diameter of Cable Over Armour (mils) N/A 1950 |
AL Weight (lb/mft) N/A 1304 |
Cable Weight (lb/mft) N/A 1575 |
Conductor Size AWG or kcmil N/A |
Neutral Wires N/A |
Neutral Size AWG N/A |
Neutral Size N/A |
Sequence Impedance Pos/Neg (µΩ/feet) N/A |
Seq Impedance Zero (µΩ/feet) N/A |
Ampacity LF=100% (A) N/A |
Ampacity LF=75% (A) N/A |
Conductor Size (AWG or kcmil) N/A |
Neutral Wires N/A |
Neutral Size (AWG) N/A |
Conductor Resistance @ 20º C (Ω / 1000 ft) N/A |
Capacitance (μF / 1000 ft) N/A |
Short-Circuit Current - Conductor - 8 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 8 Cycles - (A) N/A |
Short-Circuit Current - Conductor - 16 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 16 Cycles - (A) N/A |
Short-Circuit Current - Conductor - 24 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 24 Cycles - (A) N/A |
A250-04MC1 |
Size of Cable N/A 250-250-250-250+1 |
Phase Conductor Size AWG/MCM N/A 250 |
Number of Phase Conductors N/A 4 |
Diameter of Conductor (mils) N/A 520 |
Thickness of Conductor Insulation (mils) N/A 65 |
Size of Ground Conductor AWG/MCM N/A 1 |
Diameter of Ground (mils) N/A 299 |
Thickness of Ground Insulation (mils) N/A 55 |
Cabling Diameter (mils) N/A 1657 |
Overall Diameter of Cable Over Armour (mils) N/A 1981 |
AL Weight (lb/mft) N/A 1326 |
Cable Weight (lb/mft) N/A 1605 |
Conductor Size AWG or kcmil N/A |
Neutral Wires N/A |
Neutral Size AWG N/A |
Neutral Size N/A |
Sequence Impedance Pos/Neg (µΩ/feet) N/A |
Seq Impedance Zero (µΩ/feet) N/A |
Ampacity LF=100% (A) N/A |
Ampacity LF=75% (A) N/A |
Conductor Size (AWG or kcmil) N/A |
Neutral Wires N/A |
Neutral Size (AWG) N/A |
Conductor Resistance @ 20º C (Ω / 1000 ft) N/A |
Capacitance (μF / 1000 ft) N/A |
Short-Circuit Current - Conductor - 8 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 8 Cycles - (A) N/A |
Short-Circuit Current - Conductor - 16 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 16 Cycles - (A) N/A |
Short-Circuit Current - Conductor - 24 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 24 Cycles - (A) N/A |
A250-04MC1/0 |
Size of Cable N/A 250-250-250-250+1/0 |
Phase Conductor Size AWG/MCM N/A 250 |
Number of Phase Conductors N/A 4 |
Diameter of Conductor (mils) N/A 520 |
Thickness of Conductor Insulation (mils) N/A 65 |
Size of Ground Conductor AWG/MCM N/A 1/0 |
Diameter of Ground (mils) N/A 336 |
Thickness of Ground Insulation (mils) N/A 55 |
Cabling Diameter (mils) N/A 1657 |
Overall Diameter of Cable Over Armour (mils) N/A 1981 |
AL Weight (lb/mft) N/A 1346 |
Cable Weight (lb/mft) N/A 1629 |
Conductor Size AWG or kcmil N/A |
Neutral Wires N/A |
Neutral Size AWG N/A |
Neutral Size N/A |
Sequence Impedance Pos/Neg (µΩ/feet) N/A |
Seq Impedance Zero (µΩ/feet) N/A |
Ampacity LF=100% (A) N/A |
Ampacity LF=75% (A) N/A |
Conductor Size (AWG or kcmil) N/A |
Neutral Wires N/A |
Neutral Size (AWG) N/A |
Conductor Resistance @ 20º C (Ω / 1000 ft) N/A |
Capacitance (μF / 1000 ft) N/A |
Short-Circuit Current - Conductor - 8 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 8 Cycles - (A) N/A |
Short-Circuit Current - Conductor - 16 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 16 Cycles - (A) N/A |
Short-Circuit Current - Conductor - 24 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 24 Cycles - (A) N/A |
A250-04MC2/0 |
Size of Cable N/A 250-250-250-250+2/0 |
Phase Conductor Size AWG/MCM N/A 250 |
Number of Phase Conductors N/A 4 |
Diameter of Conductor (mils) N/A 520 |
Thickness of Conductor Insulation (mils) N/A 65 |
Size of Ground Conductor AWG/MCM N/A 2/0 |
Diameter of Ground (mils) N/A 376 |
Thickness of Ground Insulation (mils) N/A 55 |
Cabling Diameter (mils) N/A 1689 |
Overall Diameter of Cable Over Armour (mils) N/A 2013 |
AL Weight (lb/mft) N/A 1377 |
Cable Weight (lb/mft) N/A 1664 |
Conductor Size AWG or kcmil N/A |
Neutral Wires N/A |
Neutral Size AWG N/A |
Neutral Size N/A |
Sequence Impedance Pos/Neg (µΩ/feet) N/A |
Seq Impedance Zero (µΩ/feet) N/A |
Ampacity LF=100% (A) N/A |
Ampacity LF=75% (A) N/A |
Conductor Size (AWG or kcmil) N/A |
Neutral Wires N/A |
Neutral Size (AWG) N/A |
Conductor Resistance @ 20º C (Ω / 1000 ft) N/A |
Capacitance (μF / 1000 ft) N/A |
Short-Circuit Current - Conductor - 8 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 8 Cycles - (A) N/A |
Short-Circuit Current - Conductor - 16 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 16 Cycles - (A) N/A |
Short-Circuit Current - Conductor - 24 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 24 Cycles - (A) N/A |
A250-04MC3/0 |
Size of Cable N/A 250-250-250-250+3/0 |
Phase Conductor Size AWG/MCM N/A 250 |
Number of Phase Conductors N/A 4 |
Diameter of Conductor (mils) N/A 520 |
Thickness of Conductor Insulation (mils) N/A 65 |
Size of Ground Conductor AWG/MCM N/A 3/0 |
Diameter of Ground (mils) N/A 421 |
Thickness of Ground Insulation (mils) N/A 55 |
Cabling Diameter (mils) N/A 1724 |
Overall Diameter of Cable Over Armour (mils) N/A 2048 |
AL Weight (lb/mft) N/A 1416 |
Cable Weight (lb/mft) N/A 1706 |
Conductor Size AWG or kcmil N/A |
Neutral Wires N/A |
Neutral Size AWG N/A |
Neutral Size N/A |
Sequence Impedance Pos/Neg (µΩ/feet) N/A |
Seq Impedance Zero (µΩ/feet) N/A |
Ampacity LF=100% (A) N/A |
Ampacity LF=75% (A) N/A |
Conductor Size (AWG or kcmil) N/A |
Neutral Wires N/A |
Neutral Size (AWG) N/A |
Conductor Resistance @ 20º C (Ω / 1000 ft) N/A |
Capacitance (μF / 1000 ft) N/A |
Short-Circuit Current - Conductor - 8 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 8 Cycles - (A) N/A |
Short-Circuit Current - Conductor - 16 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 16 Cycles - (A) N/A |
Short-Circuit Current - Conductor - 24 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 24 Cycles - (A) N/A |
A250-04MC4/0 |
Size of Cable N/A 250-250-250-250+4/0 |
Phase Conductor Size AWG/MCM N/A 250 |
Number of Phase Conductors N/A 4 |
Diameter of Conductor (mils) N/A 520 |
Thickness of Conductor Insulation (mils) N/A 65 |
Size of Ground Conductor AWG/MCM N/A 4/0 |
Diameter of Ground (mils) N/A 476 |
Thickness of Ground Insulation (mils) N/A 55 |
Cabling Diameter (mils) N/A 1756 |
Overall Diameter of Cable Over Armour (mils) N/A 2080 |
AL Weight (lb/mft) N/A 1462 |
Cable Weight (lb/mft) N/A 1757 |
Conductor Size AWG or kcmil N/A |
Neutral Wires N/A |
Neutral Size AWG N/A |
Neutral Size N/A |
Sequence Impedance Pos/Neg (µΩ/feet) N/A |
Seq Impedance Zero (µΩ/feet) N/A |
Ampacity LF=100% (A) N/A |
Ampacity LF=75% (A) N/A |
Conductor Size (AWG or kcmil) N/A |
Neutral Wires N/A |
Neutral Size (AWG) N/A |
Conductor Resistance @ 20º C (Ω / 1000 ft) N/A |
Capacitance (μF / 1000 ft) N/A |
Short-Circuit Current - Conductor - 8 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 8 Cycles - (A) N/A |
Short-Circuit Current - Conductor - 16 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 16 Cycles - (A) N/A |
Short-Circuit Current - Conductor - 24 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 24 Cycles - (A) N/A |
A250-04MC250 |
Size of Cable N/A 250-250-250-250+250 |
Phase Conductor Size AWG/MCM N/A 250 |
Number of Phase Conductors N/A 4 |
Diameter of Conductor (mils) N/A 520 |
Thickness of Conductor Insulation (mils) N/A 65 |
Size of Ground Conductor AWG/MCM N/A 250 |
Diameter of Ground (mils) N/A 520 |
Thickness of Ground Insulation (mils) N/A 65 |
Cabling Diameter (mils) N/A 1756 |
Overall Diameter of Cable Over Armour (mils) N/A 2080 |
AL Weight (lb/mft) N/A 1498 |
Cable Weight (lb/mft) N/A 1807 |
Conductor Size AWG or kcmil N/A |
Neutral Wires N/A |
Neutral Size AWG N/A |
Neutral Size N/A |
Sequence Impedance Pos/Neg (µΩ/feet) N/A |
Seq Impedance Zero (µΩ/feet) N/A |
Ampacity LF=100% (A) N/A |
Ampacity LF=75% (A) N/A |
Conductor Size (AWG or kcmil) N/A |
Neutral Wires N/A |
Neutral Size (AWG) N/A |
Conductor Resistance @ 20º C (Ω / 1000 ft) N/A |
Capacitance (μF / 1000 ft) N/A |
Short-Circuit Current - Conductor - 8 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 8 Cycles - (A) N/A |
Short-Circuit Current - Conductor - 16 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 16 Cycles - (A) N/A |
Short-Circuit Current - Conductor - 24 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 24 Cycles - (A) N/A |
A300-04MC2 |
Size of Cable N/A 300-300-300-300+2 |
Phase Conductor Size AWG/MCM N/A 300 |
Number of Phase Conductors N/A 4 |
Diameter of Conductor (mils) N/A 571 |
Thickness of Conductor Insulation (mils) N/A 65 |
Size of Ground Conductor AWG/MCM N/A 2 |
Diameter of Ground (mils) N/A 268 |
Thickness of Ground Insulation (mils) N/A 45 |
Cabling Diameter (mils) N/A 1752 |
Overall Diameter of Cable Over Armour (mils) N/A 2076 |
AL Weight (lb/mft) N/A 1509 |
Cable Weight (lb/mft) N/A 1802 |
Conductor Size AWG or kcmil N/A |
Neutral Wires N/A |
Neutral Size AWG N/A |
Neutral Size N/A |
Sequence Impedance Pos/Neg (µΩ/feet) N/A |
Seq Impedance Zero (µΩ/feet) N/A |
Ampacity LF=100% (A) N/A |
Ampacity LF=75% (A) N/A |
Conductor Size (AWG or kcmil) N/A |
Neutral Wires N/A |
Neutral Size (AWG) N/A |
Conductor Resistance @ 20º C (Ω / 1000 ft) N/A |
Capacitance (μF / 1000 ft) N/A |
Short-Circuit Current - Conductor - 8 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 8 Cycles - (A) N/A |
Short-Circuit Current - Conductor - 16 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 16 Cycles - (A) N/A |
Short-Circuit Current - Conductor - 24 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 24 Cycles - (A) N/A |
A300-04MC1 |
Size of Cable N/A 300-300-300-300+1 |
Phase Conductor Size AWG/MCM N/A 300 |
Number of Phase Conductors N/A 4 |
Diameter of Conductor (mils) N/A 571 |
Thickness of Conductor Insulation (mils) N/A 65 |
Size of Ground Conductor AWG/MCM N/A 1 |
Diameter of Ground (mils) N/A 299 |
Thickness of Ground Insulation (mils) N/A 55 |
Cabling Diameter (mils) N/A 1752 |
Overall Diameter of Cable Over Armour (mils) N/A 2076 |
AL Weight (lb/mft) N/A 1525 |
Cable Weight (lb/mft) N/A 1826 |
Conductor Size AWG or kcmil N/A |
Neutral Wires N/A |
Neutral Size AWG N/A |
Neutral Size N/A |
Sequence Impedance Pos/Neg (µΩ/feet) N/A |
Seq Impedance Zero (µΩ/feet) N/A |
Ampacity LF=100% (A) N/A |
Ampacity LF=75% (A) N/A |
Conductor Size (AWG or kcmil) N/A |
Neutral Wires N/A |
Neutral Size (AWG) N/A |
Conductor Resistance @ 20º C (Ω / 1000 ft) N/A |
Capacitance (μF / 1000 ft) N/A |
Short-Circuit Current - Conductor - 8 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 8 Cycles - (A) N/A |
Short-Circuit Current - Conductor - 16 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 16 Cycles - (A) N/A |
Short-Circuit Current - Conductor - 24 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 24 Cycles - (A) N/A |
A300-04MC1/0 |
Size of Cable N/A 300-300-300-300+1/0 |
Phase Conductor Size AWG/MCM N/A 300 |
Number of Phase Conductors N/A 4 |
Diameter of Conductor (mils) N/A 571 |
Thickness of Conductor Insulation (mils) N/A 65 |
Size of Ground Conductor AWG/MCM N/A 1/0 |
Diameter of Ground (mils) N/A 336 |
Thickness of Ground Insulation (mils) N/A 55 |
Cabling Diameter (mils) N/A 1787 |
Overall Diameter of Cable Over Armour (mils) N/A 2111 |
AL Weight (lb/mft) N/A 1552 |
Cable Weight (lb/mft) N/A 1856 |
Conductor Size AWG or kcmil N/A |
Neutral Wires N/A |
Neutral Size AWG N/A |
Neutral Size N/A |
Sequence Impedance Pos/Neg (µΩ/feet) N/A |
Seq Impedance Zero (µΩ/feet) N/A |
Ampacity LF=100% (A) N/A |
Ampacity LF=75% (A) N/A |
Conductor Size (AWG or kcmil) N/A |
Neutral Wires N/A |
Neutral Size (AWG) N/A |
Conductor Resistance @ 20º C (Ω / 1000 ft) N/A |
Capacitance (μF / 1000 ft) N/A |
Short-Circuit Current - Conductor - 8 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 8 Cycles - (A) N/A |
Short-Circuit Current - Conductor - 16 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 16 Cycles - (A) N/A |
Short-Circuit Current - Conductor - 24 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 24 Cycles - (A) N/A |
A300-04MC2/0 |
Size of Cable N/A 300-300-300-300+2/0 |
Phase Conductor Size AWG/MCM N/A 300 |
Number of Phase Conductors N/A 4 |
Diameter of Conductor (mils) N/A 571 |
Thickness of Conductor Insulation (mils) N/A 65 |
Size of Ground Conductor AWG/MCM N/A 2/0 |
Diameter of Ground (mils) N/A 376 |
Thickness of Ground Insulation (mils) N/A 55 |
Cabling Diameter (mils) N/A 1787 |
Overall Diameter of Cable Over Armour (mils) N/A 2111 |
AL Weight (lb/mft) N/A 1577 |
Cable Weight (lb/mft) N/A 1885 |
Conductor Size AWG or kcmil N/A |
Neutral Wires N/A |
Neutral Size AWG N/A |
Neutral Size N/A |
Sequence Impedance Pos/Neg (µΩ/feet) N/A |
Seq Impedance Zero (µΩ/feet) N/A |
Ampacity LF=100% (A) N/A |
Ampacity LF=75% (A) N/A |
Conductor Size (AWG or kcmil) N/A |
Neutral Wires N/A |
Neutral Size (AWG) N/A |
Conductor Resistance @ 20º C (Ω / 1000 ft) N/A |
Capacitance (μF / 1000 ft) N/A |
Short-Circuit Current - Conductor - 8 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 8 Cycles - (A) N/A |
Short-Circuit Current - Conductor - 16 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 16 Cycles - (A) N/A |
Short-Circuit Current - Conductor - 24 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 24 Cycles - (A) N/A |
A300-04MC3/0 |
Size of Cable N/A 300-300-300-300+3/0 |
Phase Conductor Size AWG/MCM N/A 300 |
Number of Phase Conductors N/A 4 |
Diameter of Conductor (mils) N/A 571 |
Thickness of Conductor Insulation (mils) N/A 65 |
Size of Ground Conductor AWG/MCM N/A 3/0 |
Diameter of Ground (mils) N/A 421 |
Thickness of Ground Insulation (mils) N/A 55 |
Cabling Diameter (mils) N/A 1823 |
Overall Diameter of Cable Over Armour (mils) N/A 2146 |
AL Weight (lb/mft) N/A 1616 |
Cable Weight (lb/mft) N/A 1928 |
Conductor Size AWG or kcmil N/A |
Neutral Wires N/A |
Neutral Size AWG N/A |
Neutral Size N/A |
Sequence Impedance Pos/Neg (µΩ/feet) N/A |
Seq Impedance Zero (µΩ/feet) N/A |
Ampacity LF=100% (A) N/A |
Ampacity LF=75% (A) N/A |
Conductor Size (AWG or kcmil) N/A |
Neutral Wires N/A |
Neutral Size (AWG) N/A |
Conductor Resistance @ 20º C (Ω / 1000 ft) N/A |
Capacitance (μF / 1000 ft) N/A |
Short-Circuit Current - Conductor - 8 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 8 Cycles - (A) N/A |
Short-Circuit Current - Conductor - 16 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 16 Cycles - (A) N/A |
Short-Circuit Current - Conductor - 24 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 24 Cycles - (A) N/A |
A300-04MC4/0 |
Size of Cable N/A 300-300-300-300+4/0 |
Phase Conductor Size AWG/MCM N/A 300 |
Number of Phase Conductors N/A 4 |
Diameter of Conductor (mils) N/A 571 |
Thickness of Conductor Insulation (mils) N/A 65 |
Size of Ground Conductor AWG/MCM N/A 4/0 |
Diameter of Ground (mils) N/A 476 |
Thickness of Ground Insulation (mils) N/A 55 |
Cabling Diameter (mils) N/A 1858 |
Overall Diameter of Cable Over Armour (mils) N/A 2182 |
AL Weight (lb/mft) N/A 1663 |
Cable Weight (lb/mft) N/A 1979 |
Conductor Size AWG or kcmil N/A |
Neutral Wires N/A |
Neutral Size AWG N/A |
Neutral Size N/A |
Sequence Impedance Pos/Neg (µΩ/feet) N/A |
Seq Impedance Zero (µΩ/feet) N/A |
Ampacity LF=100% (A) N/A |
Ampacity LF=75% (A) N/A |
Conductor Size (AWG or kcmil) N/A |
Neutral Wires N/A |
Neutral Size (AWG) N/A |
Conductor Resistance @ 20º C (Ω / 1000 ft) N/A |
Capacitance (μF / 1000 ft) N/A |
Short-Circuit Current - Conductor - 8 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 8 Cycles - (A) N/A |
Short-Circuit Current - Conductor - 16 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 16 Cycles - (A) N/A |
Short-Circuit Current - Conductor - 24 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 24 Cycles - (A) N/A |
A300-04MC250 |
Size of Cable N/A 300-300-300-300+250 |
Phase Conductor Size AWG/MCM N/A 300 |
Number of Phase Conductors N/A 4 |
Diameter of Conductor (mils) N/A 571 |
Thickness of Conductor Insulation (mils) N/A 65 |
Size of Ground Conductor AWG/MCM N/A 250 |
Diameter of Ground (mils) N/A 520 |
Thickness of Ground Insulation (mils) N/A 65 |
Cabling Diameter (mils) N/A 1894 |
Overall Diameter of Cable Over Armour (mils) N/A 2217 |
AL Weight (lb/mft) N/A 1706 |
Cable Weight (lb/mft) N/A 2036 |
Conductor Size AWG or kcmil N/A |
Neutral Wires N/A |
Neutral Size AWG N/A |
Neutral Size N/A |
Sequence Impedance Pos/Neg (µΩ/feet) N/A |
Seq Impedance Zero (µΩ/feet) N/A |
Ampacity LF=100% (A) N/A |
Ampacity LF=75% (A) N/A |
Conductor Size (AWG or kcmil) N/A |
Neutral Wires N/A |
Neutral Size (AWG) N/A |
Conductor Resistance @ 20º C (Ω / 1000 ft) N/A |
Capacitance (μF / 1000 ft) N/A |
Short-Circuit Current - Conductor - 8 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 8 Cycles - (A) N/A |
Short-Circuit Current - Conductor - 16 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 16 Cycles - (A) N/A |
Short-Circuit Current - Conductor - 24 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 24 Cycles - (A) N/A |
A300-04MC300 |
Size of Cable N/A 300-300-300-300+300 |
Phase Conductor Size AWG/MCM N/A 300 |
Number of Phase Conductors N/A 4 |
Diameter of Conductor (mils) N/A 571 |
Thickness of Conductor Insulation (mils) N/A 65 |
Size of Ground Conductor AWG/MCM N/A 300 |
Diameter of Ground (mils) N/A 571 |
Thickness of Ground Insulation (mils) N/A 65 |
Cabling Diameter (mils) N/A 1894 |
Overall Diameter of Cable Over Armour (mils) N/A 2217 |
AL Weight (lb/mft) N/A 1751 |
Cable Weight (lb/mft) N/A 2086 |
Conductor Size AWG or kcmil N/A |
Neutral Wires N/A |
Neutral Size AWG N/A |
Neutral Size N/A |
Sequence Impedance Pos/Neg (µΩ/feet) N/A |
Seq Impedance Zero (µΩ/feet) N/A |
Ampacity LF=100% (A) N/A |
Ampacity LF=75% (A) N/A |
Conductor Size (AWG or kcmil) N/A |
Neutral Wires N/A |
Neutral Size (AWG) N/A |
Conductor Resistance @ 20º C (Ω / 1000 ft) N/A |
Capacitance (μF / 1000 ft) N/A |
Short-Circuit Current - Conductor - 8 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 8 Cycles - (A) N/A |
Short-Circuit Current - Conductor - 16 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 16 Cycles - (A) N/A |
Short-Circuit Current - Conductor - 24 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 24 Cycles - (A) N/A |
A350-04MC2 |
Size of Cable N/A 350-350-350-350+2 |
Phase Conductor Size AWG/MCM N/A 350 |
Number of Phase Conductors N/A 4 |
Diameter of Conductor (mils) N/A 614 |
Thickness of Conductor Insulation (mils) N/A 65 |
Size of Ground Conductor AWG/MCM N/A 2 |
Diameter of Ground (mils) N/A 268 |
Thickness of Ground Insulation (mils) N/A 45 |
Cabling Diameter (mils) N/A 1846 |
Overall Diameter of Cable Over Armour (mils) N/A 2170 |
AL Weight (lb/mft) N/A 1709 |
Cable Weight (lb/mft) N/A 2019 |
Conductor Size AWG or kcmil N/A |
Neutral Wires N/A |
Neutral Size AWG N/A |
Neutral Size N/A |
Sequence Impedance Pos/Neg (µΩ/feet) N/A |
Seq Impedance Zero (µΩ/feet) N/A |
Ampacity LF=100% (A) N/A |
Ampacity LF=75% (A) N/A |
Conductor Size (AWG or kcmil) N/A |
Neutral Wires N/A |
Neutral Size (AWG) N/A |
Conductor Resistance @ 20º C (Ω / 1000 ft) N/A |
Capacitance (μF / 1000 ft) N/A |
Short-Circuit Current - Conductor - 8 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 8 Cycles - (A) N/A |
Short-Circuit Current - Conductor - 16 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 16 Cycles - (A) N/A |
Short-Circuit Current - Conductor - 24 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 24 Cycles - (A) N/A |
A350-04MC1 |
Size of Cable N/A 350-350-350-350+1 |
Phase Conductor Size AWG/MCM N/A 350 |
Number of Phase Conductors N/A 4 |
Diameter of Conductor (mils) N/A 614 |
Thickness of Conductor Insulation (mils) N/A 65 |
Size of Ground Conductor AWG/MCM N/A 1 |
Diameter of Ground (mils) N/A 299 |
Thickness of Ground Insulation (mils) N/A 55 |
Cabling Diameter (mils) N/A 1862 |
Overall Diameter of Cable Over Armour (mils) N/A 2186 |
AL Weight (lb/mft) N/A 1728 |
Cable Weight (lb/mft) N/A 2047 |
Conductor Size AWG or kcmil N/A |
Neutral Wires N/A |
Neutral Size AWG N/A |
Neutral Size N/A |
Sequence Impedance Pos/Neg (µΩ/feet) N/A |
Seq Impedance Zero (µΩ/feet) N/A |
Ampacity LF=100% (A) N/A |
Ampacity LF=75% (A) N/A |
Conductor Size (AWG or kcmil) N/A |
Neutral Wires N/A |
Neutral Size (AWG) N/A |
Conductor Resistance @ 20º C (Ω / 1000 ft) N/A |
Capacitance (μF / 1000 ft) N/A |
Short-Circuit Current - Conductor - 8 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 8 Cycles - (A) N/A |
Short-Circuit Current - Conductor - 16 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 16 Cycles - (A) N/A |
Short-Circuit Current - Conductor - 24 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 24 Cycles - (A) N/A |
A350-04MC1/0 |
Size of Cable N/A 350-350-350-350+1/0 |
Phase Conductor Size AWG/MCM N/A 350 |
Number of Phase Conductors N/A 4 |
Diameter of Conductor (mils) N/A 614 |
Thickness of Conductor Insulation (mils) N/A 65 |
Size of Ground Conductor AWG/MCM N/A 1/0 |
Diameter of Ground (mils) N/A 336 |
Thickness of Ground Insulation (mils) N/A 55 |
Cabling Diameter (mils) N/A 1862 |
Overall Diameter of Cable Over Armour (mils) N/A 2186 |
AL Weight (lb/mft) N/A 1748 |
Cable Weight (lb/mft) N/A 2070 |
Conductor Size AWG or kcmil N/A |
Neutral Wires N/A |
Neutral Size AWG N/A |
Neutral Size N/A |
Sequence Impedance Pos/Neg (µΩ/feet) N/A |
Seq Impedance Zero (µΩ/feet) N/A |
Ampacity LF=100% (A) N/A |
Ampacity LF=75% (A) N/A |
Conductor Size (AWG or kcmil) N/A |
Neutral Wires N/A |
Neutral Size (AWG) N/A |
Conductor Resistance @ 20º C (Ω / 1000 ft) N/A |
Capacitance (μF / 1000 ft) N/A |
Short-Circuit Current - Conductor - 8 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 8 Cycles - (A) N/A |
Short-Circuit Current - Conductor - 16 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 16 Cycles - (A) N/A |
Short-Circuit Current - Conductor - 24 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 24 Cycles - (A) N/A |
A350-04MC2/0 |
Size of Cable N/A 350-350-350-350+2/0 |
Phase Conductor Size AWG/MCM N/A 350 |
Number of Phase Conductors N/A 4 |
Diameter of Conductor (mils) N/A 614 |
Thickness of Conductor Insulation (mils) N/A 65 |
Size of Ground Conductor AWG/MCM N/A 2/0 |
Diameter of Ground (mils) N/A 376 |
Thickness of Ground Insulation (mils) N/A 55 |
Cabling Diameter (mils) N/A 1898 |
Overall Diameter of Cable Over Armour (mils) N/A 2221 |
AL Weight (lb/mft) N/A 1780 |
Cable Weight (lb/mft) N/A 2105 |
Conductor Size AWG or kcmil N/A |
Neutral Wires N/A |
Neutral Size AWG N/A |
Neutral Size N/A |
Sequence Impedance Pos/Neg (µΩ/feet) N/A |
Seq Impedance Zero (µΩ/feet) N/A |
Ampacity LF=100% (A) N/A |
Ampacity LF=75% (A) N/A |
Conductor Size (AWG or kcmil) N/A |
Neutral Wires N/A |
Neutral Size (AWG) N/A |
Conductor Resistance @ 20º C (Ω / 1000 ft) N/A |
Capacitance (μF / 1000 ft) N/A |
Short-Circuit Current - Conductor - 8 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 8 Cycles - (A) N/A |
Short-Circuit Current - Conductor - 16 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 16 Cycles - (A) N/A |
Short-Circuit Current - Conductor - 24 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 24 Cycles - (A) N/A |
A350-04MC3/0 |
Size of Cable N/A 350-350-350-350+3/0 |
Phase Conductor Size AWG/MCM N/A 350 |
Number of Phase Conductors N/A 4 |
Diameter of Conductor (mils) N/A 614 |
Thickness of Conductor Insulation (mils) N/A 65 |
Size of Ground Conductor AWG/MCM N/A 3/0 |
Diameter of Ground (mils) N/A 421 |
Thickness of Ground Insulation (mils) N/A 55 |
Cabling Diameter (mils) N/A 1933 |
Overall Diameter of Cable Over Armour (mils) N/A 2257 |
AL Weight (lb/mft) N/A 1818 |
Cable Weight (lb/mft) N/A 2148 |
Conductor Size AWG or kcmil N/A |
Neutral Wires N/A |
Neutral Size AWG N/A |
Neutral Size N/A |
Sequence Impedance Pos/Neg (µΩ/feet) N/A |
Seq Impedance Zero (µΩ/feet) N/A |
Ampacity LF=100% (A) N/A |
Ampacity LF=75% (A) N/A |
Conductor Size (AWG or kcmil) N/A |
Neutral Wires N/A |
Neutral Size (AWG) N/A |
Conductor Resistance @ 20º C (Ω / 1000 ft) N/A |
Capacitance (μF / 1000 ft) N/A |
Short-Circuit Current - Conductor - 8 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 8 Cycles - (A) N/A |
Short-Circuit Current - Conductor - 16 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 16 Cycles - (A) N/A |
Short-Circuit Current - Conductor - 24 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 24 Cycles - (A) N/A |
A350-04MC4/0 |
Size of Cable N/A 350-350-350-350+4/0 |
Phase Conductor Size AWG/MCM N/A 350 |
Number of Phase Conductors N/A 4 |
Diameter of Conductor (mils) N/A 614 |
Thickness of Conductor Insulation (mils) N/A 65 |
Size of Ground Conductor AWG/MCM N/A 4/0 |
Diameter of Ground (mils) N/A 476 |
Thickness of Ground Insulation (mils) N/A 55 |
Cabling Diameter (mils) N/A 1933 |
Overall Diameter of Cable Over Armour (mils) N/A 2257 |
AL Weight (lb/mft) N/A 1858 |
Cable Weight (lb/mft) N/A 2193 |
Conductor Size AWG or kcmil N/A |
Neutral Wires N/A |
Neutral Size AWG N/A |
Neutral Size N/A |
Sequence Impedance Pos/Neg (µΩ/feet) N/A |
Seq Impedance Zero (µΩ/feet) N/A |
Ampacity LF=100% (A) N/A |
Ampacity LF=75% (A) N/A |
Conductor Size (AWG or kcmil) N/A |
Neutral Wires N/A |
Neutral Size (AWG) N/A |
Conductor Resistance @ 20º C (Ω / 1000 ft) N/A |
Capacitance (μF / 1000 ft) N/A |
Short-Circuit Current - Conductor - 8 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 8 Cycles - (A) N/A |
Short-Circuit Current - Conductor - 16 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 16 Cycles - (A) N/A |
Short-Circuit Current - Conductor - 24 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 24 Cycles - (A) N/A |
A350-04MC250 |
Size of Cable N/A 350-350-350-350+250 |
Phase Conductor Size AWG/MCM N/A 350 |
Number of Phase Conductors N/A 4 |
Diameter of Conductor (mils) N/A 614 |
Thickness of Conductor Insulation (mils) N/A 65 |
Size of Ground Conductor AWG/MCM N/A 250 |
Diameter of Ground (mils) N/A 520 |
Thickness of Ground Insulation (mils) N/A 65 |
Cabling Diameter (mils) N/A 1972 |
Overall Diameter of Cable Over Armour (mils) N/A 2296 |
AL Weight (lb/mft) N/A 1902 |
Cable Weight (lb/mft) N/A 2250 |
Conductor Size AWG or kcmil N/A |
Neutral Wires N/A |
Neutral Size AWG N/A |
Neutral Size N/A |
Sequence Impedance Pos/Neg (µΩ/feet) N/A |
Seq Impedance Zero (µΩ/feet) N/A |
Ampacity LF=100% (A) N/A |
Ampacity LF=75% (A) N/A |
Conductor Size (AWG or kcmil) N/A |
Neutral Wires N/A |
Neutral Size (AWG) N/A |
Conductor Resistance @ 20º C (Ω / 1000 ft) N/A |
Capacitance (μF / 1000 ft) N/A |
Short-Circuit Current - Conductor - 8 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 8 Cycles - (A) N/A |
Short-Circuit Current - Conductor - 16 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 16 Cycles - (A) N/A |
Short-Circuit Current - Conductor - 24 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 24 Cycles - (A) N/A |
A350-04MC300 |
Size of Cable N/A 350-350-350-350+300 |
Phase Conductor Size AWG/MCM N/A 350 |
Number of Phase Conductors N/A 4 |
Diameter of Conductor (mils) N/A 614 |
Thickness of Conductor Insulation (mils) N/A 65 |
Size of Ground Conductor AWG/MCM N/A 300 |
Diameter of Ground (mils) N/A 571 |
Thickness of Ground Insulation (mils) N/A 65 |
Cabling Diameter (mils) N/A 2008 |
Overall Diameter of Cable Over Armour (mils) N/A 2331 |
AL Weight (lb/mft) N/A 1954 |
Cable Weight (lb/mft) N/A 2308 |
Conductor Size AWG or kcmil N/A |
Neutral Wires N/A |
Neutral Size AWG N/A |
Neutral Size N/A |
Sequence Impedance Pos/Neg (µΩ/feet) N/A |
Seq Impedance Zero (µΩ/feet) N/A |
Ampacity LF=100% (A) N/A |
Ampacity LF=75% (A) N/A |
Conductor Size (AWG or kcmil) N/A |
Neutral Wires N/A |
Neutral Size (AWG) N/A |
Conductor Resistance @ 20º C (Ω / 1000 ft) N/A |
Capacitance (μF / 1000 ft) N/A |
Short-Circuit Current - Conductor - 8 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 8 Cycles - (A) N/A |
Short-Circuit Current - Conductor - 16 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 16 Cycles - (A) N/A |
Short-Circuit Current - Conductor - 24 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 24 Cycles - (A) N/A |
A350-04MC350 |
Size of Cable N/A 350-350-350-350+350 |
Phase Conductor Size AWG/MCM N/A 350 |
Number of Phase Conductors N/A 4 |
Diameter of Conductor (mils) N/A 614 |
Thickness of Conductor Insulation (mils) N/A 65 |
Size of Ground Conductor AWG/MCM N/A 350 |
Diameter of Ground (mils) N/A 614 |
Thickness of Ground Insulation (mils) N/A 65 |
Cabling Diameter (mils) N/A 2008 |
Overall Diameter of Cable Over Armour (mils) N/A 2331 |
AL Weight (lb/mft) N/A 1999 |
Cable Weight (lb/mft) N/A 2357 |
Conductor Size AWG or kcmil N/A |
Neutral Wires N/A |
Neutral Size AWG N/A |
Neutral Size N/A |
Sequence Impedance Pos/Neg (µΩ/feet) N/A |
Seq Impedance Zero (µΩ/feet) N/A |
Ampacity LF=100% (A) N/A |
Ampacity LF=75% (A) N/A |
Conductor Size (AWG or kcmil) N/A |
Neutral Wires N/A |
Neutral Size (AWG) N/A |
Conductor Resistance @ 20º C (Ω / 1000 ft) N/A |
Capacitance (μF / 1000 ft) N/A |
Short-Circuit Current - Conductor - 8 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 8 Cycles - (A) N/A |
Short-Circuit Current - Conductor - 16 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 16 Cycles - (A) N/A |
Short-Circuit Current - Conductor - 24 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 24 Cycles - (A) N/A |
A400-04MC1 |
Size of Cable N/A 400-400-400-400+1 |
Phase Conductor Size AWG/MCM N/A 400 |
Number of Phase Conductors N/A 4 |
Diameter of Conductor (mils) N/A 657 |
Thickness of Conductor Insulation (mils) N/A 65 |
Size of Ground Conductor AWG/MCM N/A 1 |
Diameter of Ground (mils) N/A 299 |
Thickness of Ground Insulation (mils) N/A 55 |
Cabling Diameter (mils) N/A 1969 |
Overall Diameter of Cable Over Armour (mils) N/A 2292 |
AL Weight (lb/mft) N/A 1936 |
Cable Weight (lb/mft) N/A 2274 |
Conductor Size AWG or kcmil N/A |
Neutral Wires N/A |
Neutral Size AWG N/A |
Neutral Size N/A |
Sequence Impedance Pos/Neg (µΩ/feet) N/A |
Seq Impedance Zero (µΩ/feet) N/A |
Ampacity LF=100% (A) N/A |
Ampacity LF=75% (A) N/A |
Conductor Size (AWG or kcmil) N/A |
Neutral Wires N/A |
Neutral Size (AWG) N/A |
Conductor Resistance @ 20º C (Ω / 1000 ft) N/A |
Capacitance (μF / 1000 ft) N/A |
Short-Circuit Current - Conductor - 8 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 8 Cycles - (A) N/A |
Short-Circuit Current - Conductor - 16 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 16 Cycles - (A) N/A |
Short-Circuit Current - Conductor - 24 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 24 Cycles - (A) N/A |
A400-04MC1/0 |
Size of Cable N/A 400-400-400-400+1/0 |
Phase Conductor Size AWG/MCM N/A 400 |
Number of Phase Conductors N/A 4 |
Diameter of Conductor (mils) N/A 657 |
Thickness of Conductor Insulation (mils) N/A 65 |
Size of Ground Conductor AWG/MCM N/A 1/0 |
Diameter of Ground (mils) N/A 336 |
Thickness of Ground Insulation (mils) N/A 55 |
Cabling Diameter (mils) N/A 1969 |
Overall Diameter of Cable Over Armour (mils) N/A 2292 |
AL Weight (lb/mft) N/A 1957 |
Cable Weight (lb/mft) N/A 2297 |
Conductor Size AWG or kcmil N/A |
Neutral Wires N/A |
Neutral Size AWG N/A |
Neutral Size N/A |
Sequence Impedance Pos/Neg (µΩ/feet) N/A |
Seq Impedance Zero (µΩ/feet) N/A |
Ampacity LF=100% (A) N/A |
Ampacity LF=75% (A) N/A |
Conductor Size (AWG or kcmil) N/A |
Neutral Wires N/A |
Neutral Size (AWG) N/A |
Conductor Resistance @ 20º C (Ω / 1000 ft) N/A |
Capacitance (μF / 1000 ft) N/A |
Short-Circuit Current - Conductor - 8 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 8 Cycles - (A) N/A |
Short-Circuit Current - Conductor - 16 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 16 Cycles - (A) N/A |
Short-Circuit Current - Conductor - 24 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 24 Cycles - (A) N/A |
A400-04MC2/0 |
Size of Cable N/A 400-400-400-400+2/0 |
Phase Conductor Size AWG/MCM N/A 400 |
Number of Phase Conductors N/A 4 |
Diameter of Conductor (mils) N/A 657 |
Thickness of Conductor Insulation (mils) N/A 65 |
Size of Ground Conductor AWG/MCM N/A 2/0 |
Diameter of Ground (mils) N/A 376 |
Thickness of Ground Insulation (mils) N/A 55 |
Cabling Diameter (mils) N/A 2008 |
Overall Diameter of Cable Over Armour (mils) N/A 2331 |
AL Weight (lb/mft) N/A 1989 |
Cable Weight (lb/mft) N/A 2333 |
Conductor Size AWG or kcmil N/A |
Neutral Wires N/A |
Neutral Size AWG N/A |
Neutral Size N/A |
Sequence Impedance Pos/Neg (µΩ/feet) N/A |
Seq Impedance Zero (µΩ/feet) N/A |
Ampacity LF=100% (A) N/A |
Ampacity LF=75% (A) N/A |
Conductor Size (AWG or kcmil) N/A |
Neutral Wires N/A |
Neutral Size (AWG) N/A |
Conductor Resistance @ 20º C (Ω / 1000 ft) N/A |
Capacitance (μF / 1000 ft) N/A |
Short-Circuit Current - Conductor - 8 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 8 Cycles - (A) N/A |
Short-Circuit Current - Conductor - 16 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 16 Cycles - (A) N/A |
Short-Circuit Current - Conductor - 24 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 24 Cycles - (A) N/A |
A400-04MC3/0 |
Size of Cable N/A 400-400-400-400+3/0 |
Phase Conductor Size AWG/MCM N/A 400 |
Number of Phase Conductors N/A 4 |
Diameter of Conductor (mils) N/A 657 |
Thickness of Conductor Insulation (mils) N/A 65 |
Size of Ground Conductor AWG/MCM N/A 3/0 |
Diameter of Ground (mils) N/A 421 |
Thickness of Ground Insulation (mils) N/A 55 |
Cabling Diameter (mils) N/A 2008 |
Overall Diameter of Cable Over Armour (mils) N/A 2331 |
AL Weight (lb/mft) N/A 2021 |
Cable Weight (lb/mft) N/A 2369 |
Conductor Size AWG or kcmil N/A |
Neutral Wires N/A |
Neutral Size AWG N/A |
Neutral Size N/A |
Sequence Impedance Pos/Neg (µΩ/feet) N/A |
Seq Impedance Zero (µΩ/feet) N/A |
Ampacity LF=100% (A) N/A |
Ampacity LF=75% (A) N/A |
Conductor Size (AWG or kcmil) N/A |
Neutral Wires N/A |
Neutral Size (AWG) N/A |
Conductor Resistance @ 20º C (Ω / 1000 ft) N/A |
Capacitance (μF / 1000 ft) N/A |
Short-Circuit Current - Conductor - 8 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 8 Cycles - (A) N/A |
Short-Circuit Current - Conductor - 16 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 16 Cycles - (A) N/A |
Short-Circuit Current - Conductor - 24 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 24 Cycles - (A) N/A |
A400-04MC4/0 |
Size of Cable N/A 400-400-400-400+4/0 |
Phase Conductor Size AWG/MCM N/A 400 |
Number of Phase Conductors N/A 4 |
Diameter of Conductor (mils) N/A 657 |
Thickness of Conductor Insulation (mils) N/A 65 |
Size of Ground Conductor AWG/MCM N/A 4/0 |
Diameter of Ground (mils) N/A 476 |
Thickness of Ground Insulation (mils) N/A 55 |
Cabling Diameter (mils) N/A 2047 |
Overall Diameter of Cable Over Armour (mils) N/A 2371 |
AL Weight (lb/mft) N/A 2069 |
Cable Weight (lb/mft) N/A 2422 |
Conductor Size AWG or kcmil N/A |
Neutral Wires N/A |
Neutral Size AWG N/A |
Neutral Size N/A |
Sequence Impedance Pos/Neg (µΩ/feet) N/A |
Seq Impedance Zero (µΩ/feet) N/A |
Ampacity LF=100% (A) N/A |
Ampacity LF=75% (A) N/A |
Conductor Size (AWG or kcmil) N/A |
Neutral Wires N/A |
Neutral Size (AWG) N/A |
Conductor Resistance @ 20º C (Ω / 1000 ft) N/A |
Capacitance (μF / 1000 ft) N/A |
Short-Circuit Current - Conductor - 8 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 8 Cycles - (A) N/A |
Short-Circuit Current - Conductor - 16 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 16 Cycles - (A) N/A |
Short-Circuit Current - Conductor - 24 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 24 Cycles - (A) N/A |
A400-04MC250 |
Size of Cable N/A 400-400-400-400+250 |
Phase Conductor Size AWG/MCM N/A 400 |
Number of Phase Conductors N/A 4 |
Diameter of Conductor (mils) N/A 657 |
Thickness of Conductor Insulation (mils) N/A 65 |
Size of Ground Conductor AWG/MCM N/A 250 |
Diameter of Ground (mils) N/A 520 |
Thickness of Ground Insulation (mils) N/A 65 |
Cabling Diameter (mils) N/A 2087 |
Overall Diameter of Cable Over Armour (mils) N/A 2410 |
AL Weight (lb/mft) N/A 2112 |
Cable Weight (lb/mft) N/A 2479 |
Conductor Size AWG or kcmil N/A |
Neutral Wires N/A |
Neutral Size AWG N/A |
Neutral Size N/A |
Sequence Impedance Pos/Neg (µΩ/feet) N/A |
Seq Impedance Zero (µΩ/feet) N/A |
Ampacity LF=100% (A) N/A |
Ampacity LF=75% (A) N/A |
Conductor Size (AWG or kcmil) N/A |
Neutral Wires N/A |
Neutral Size (AWG) N/A |
Conductor Resistance @ 20º C (Ω / 1000 ft) N/A |
Capacitance (μF / 1000 ft) N/A |
Short-Circuit Current - Conductor - 8 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 8 Cycles - (A) N/A |
Short-Circuit Current - Conductor - 16 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 16 Cycles - (A) N/A |
Short-Circuit Current - Conductor - 24 Cycles - (A) N/A |
Short-Circuit Current - Shield Wires - 24 Cycles - (A) N/A |