All Categories > Control Cables & Portable Power Cables > Control Cables > Control Cable/Power Cable FR-XLPE > Control Cable/Power Cable FR-XLPE Insulated Conductors, XLPO Jacket, 600V > Power Cable FR-XLPE Insulated Conductors, XLPO Jacket, 600V > Power Cable FR-XLPE Insulated Conductors XLPO Jacket, 600V > View Items  

Power Cable FR-XLPE Insulated Conductors XLPO Jacket, 600V

Check up to five results to perform an action.

Applications
Flame retardant control/power cable in free air, raceway and direct burial, for use in wet or dry locations. Rated at 90 ºC wet or dry. Permitted for Exposed Run use in accordance with NEC for 3 or more conductors . Approved for direct burial, Class I, Div. 2 industrial hazardous locations per NEC. Sunlight-and weather-resistant. Meets cold bend test at -40 ºC.

Construction
8 AWG thru 750 kcmil annealed stranded copper conductors per ASTM B33. Class B stranding per ASTM B8. Flame-retardant FR-XLPE insulation, XLPO jacket, color-coded per ICEA Method 1; Table E-1. Sizes 8 AWG and larger are color-coded per ICEA Method 4; Individual conductors colored black with conductor number surface printed in contrasting ink

Standards
  • Listed by UL as Type TC per Standard 1277 for Tray Cables.
  • Cables UL listed for Direct Burial.
  • Individual conductors pass UL 1581 VW-1 flame test.
  • Individual conductors UL44 listed as Type XHHW-2.
  • Overall jacket UL listed as Sunlight Resistant.
  • Cables with grounding conductor UL listed for Open Wiring.
  • Cables pass IEEE-383 ribbon burner flame test.
  • Cables pass IEEE1202/CSA FT4 (70,000 BTU/hr) cable tray flame test.
  • Cables meet requirements of ICEA S-73-532, NEMA WC70 for Control Cables.
  • Cables meet requirements of ICEA T-29-520 AND CSA FT-4
Notes
  • Cables may be supplied with an insulated ground and marked ""Open Wiring.""
  • Standard color coding is Method 1 for NEC applications per Appendix E, Table E-2 of ICEA S-73-532(TECH I006). This color coding method omits white and green from the color sequence. A white or green conductor can be supplied on request.
  • Color Coding also available ICEA Method 1, Table E-1; power sizes, ICEA Method 4.
Options
  • Bare or Tinned Copper
  • Flexible stranded conductors
  • E1 or E2 color codes
  • EPR Insulation
  • PVC, CPE, CSPE jackets
  • Overall copper tape shield
  • Overall copper braid shield
  • Overall longitudinal corrugated copper shield
  • Overall Mylar tape shield with drain wire
  • 1000 volt rated construction
Consult AWG for a variety of alternate constructions for specific applications.





    Download PDF Download PDF   
    Email Email This Page  
    Save To Favorites Save To Favorites
  
   
  Results 1 - 33 of 33 1 

Item #

Number
of
Conductors

Conductor
Size
AWG

Conductor
Stranding

Ground
Wire
Size
AWG

Insulation
Thickness
(mm)

Nominal
Jacket
Thickness
(in)

Nominal
Jacket
Thickness
(mm)

Nominal
Cable
O.D.
(in)

Nominal
Cable
O.D.
(mm)

Approximate
Weight
/MFT
(lb)

Approximate
Cable
Weight
kg/km

08-XLPO-2 2 8 7 - 0.045 0.060 1.5 0.625 15.9 199 295
08-XLPO-3 3 8 7 - 0.045 0.060 1.5 0.665 16.9 296 438
08-XLPO-3G 3+GRD 8 7 10 0.045 0.060 1.5 0.665 16.9 321 475
08-XLPO-4 4 8 7 - 0.045 0.060 1.5 0.730 18.5 383 567
06-XLPO-2 2 6 7 - 0.045 0.060 1.5 0.705 17.9 306 453
06-XLPO-3 3 6 7 - 0.045 0.060 1.5 0.750 19.1 413 611
06-XLPO-3G 3+GRD 6 7 8 0.045 0.060 1.5 0.750 19.1 459 679
06-XLPO-4 4 6 7 - 0.045 0.060 1.5 0.825 21.0 528 781
04-XLPO-2 2 4 7 - 0.045 0.060 1.5 0.805 20.4 437 647
04-XLPO-3 3 4 7 - 0.045 0.060 1.5 0.860 21.8 597 884
04-XLPO-3G 3+GRD 4 7 8 0.045 0.060 1.5 0.860 21.8 643 952
04-XLPO-4 4 4 7 - 0.045 0.080 2 0.990 25.1 803 1188
02-XLPO-2 2 2 7 - 0.045 0.080 2 0.975 24.8 672 1001
02-XLPO-3 3 2 7 - 0.045 0.080 2 1.035 26.3 915 1352
02-XLPO-3G 3+GRD 2 7 6 0.045 0.080 2 1.035 26.3 991 1467
02-XLPO-4 4 2 7 - 0.045 0.080 2 1.140 29.0 1175 1739
1/0-XLPO-3 3 1/0 19 - 0.055 0.080 2 1.240 31.5 1399 2084
1/0-XLPO-3G 3+GRD 1/0 19 6 0.055 0.080 2 1.240 31.5 1471 2192
1/0-XLPO-4 4 1/0 19 - 0.055 0.080 2 1.370 34.5 1794 2673
2/0-XLPO-3 3 2/0 19 - 0.055 0.080 2 1.340 34.0 1707 2543
2/0-XLPO-3G 3+GRD 2/0 19 6 0.055 0.080 2 1.340 34.0 1778 2649
2/0-XLPO-4 4 2/0 19 - 0.055 0.080 2 1.480 37.6 2203 3282
4/0-XLPO-3 3 4/0 19 - 0.055 0.080 2 1.580 40.1 2578 3841
4/0-XLPO-3G 3+GRD 4/0 19 4 0.055 0.080 2 1.580 40.1 2734 4046
4/0-XLPO-4 4 4/0 19 - 0.055 0.11 2.8 1.810 46.0 3455 5113
350-XLPO-3 3 350 37 - 0.065 0.11 2.8 2.030 51.6 4251 6291
350-XLPO-3G 3+GRD 350 37 3 0.065 0.11 2.8 2.030 51.6 4385 6490
350-XLPO-4 4 350 37 - 0.065 0.11 2.8 2.240 56.9 5505 8147
500-XLPO-3 3 500 37 - 0.065 0.11 2.8 2.320 58.9 5869 8686
500-XLPO-3G 3+GRD 500 37 2 0.065 0.11 2.8 2.320 58.9 6092 9016
500-XLPO-4 4 500 37 - 0.065 0.11 2.8 2.740 69.6 7668 11349
750-XLPO-3 3 750 61 - 0.08 0.14 3.6 2.860 72.6 8730 12920
750-XLPO-3G 3+GRD 750 61 1 0.08 0.14 3.6 2.860 72.6 8976 13284