A POWERFUL SOLUTION
Applications
For use on single phase and three phase primary underground distribution systems operating at 25 kV phase to phase at 100 % insulation level. Suitable for either direct burial or installation in ducts.

Construction
Copper concentrically stranded compressed conductor, triple single head extruded conductor shield, EPR (ethylene propylene rubber) insulation and easy strippable insulation shield, all dry cured; solid bare copper wires uniformly spaced around the cable as a concentric neutral; LLDPE jacket with extruded longitudinal colored stripes, surface printed.

Standards
  • AEIC CS8 Specification for Extruded Dielectric Shielded Power Cables Rated 5 through 46 kV
  • ICEA S-94-649 Standard for Concentric Neutral Cables Rated 5,000 - 46,000 V
  • ICEA T-31-610 Guide for Conducting a Longitudinal Water Penetration Resistance Tests on Blocked Conductors
  • ICEA T-34-664 Test Method for Conducting Longitudinal Water Penetration Resistance Tests on Longitudinal Water Blocked Cables
Notes
  • Maximum conductor temperature: 90 ºC normal continuous, 130 ºC overload, 250 ºC short circuit.
1 - 5 of 5 | Results Per Page | View | Unit of Measure
1 

Item #

Conductor
Size AWG

Conductor
Stranding

Copper
Neutral
No. of
Wires

Copper
Neutral
Size
AWG

Conductor
Diameter

Diameter
Over
Insulation

Diameter
Over
Insulation
Shield

Diameter
Over
Neutral
Wires

Diameter
Over
Embedded
Jacket

Total w/o Jacket Weight

Total w/ Embedded Jacket Weight

Ampacity
1/C
Direct
Buried

Ampacity
1/C
Duct
Buried

Ampacity
1/C
Duct In Air

260-EPR-18 N/A 1 N/A 19 N/A 13 N/A 12 N/A 0.330 Inches N/A 0.910 Inches N/A 0.970 Inches N/A 1.100 Inches N/A 1.200 Inches N/A 951 Lbs N/A 1032 Lbs N/A 245 Amps N/A 185 Amps N/A 162 Amps
260-EPR-19 N/A 1/0 N/A 19 N/A 16 N/A 12 N/A 0.370 Inches N/A 0.950 Inches N/A 1.010 Inches N/A 1.160 Inches N/A 1.260 Inches N/A 1107 Lbs N/A 1190 Lbs N/A 280 Amps N/A 215 Amps N/A 189 Amps
260-EPR-20 N/A 2/0 N/A 19 N/A 20 N/A 12 N/A 0.420 Inches N/A 0.990 Inches N/A 1.060 Inches N/A 1.190 Inches N/A 1.290 Inches N/A 1320 Lbs N/A 1420 Lbs N/A 315 Amps N/A 240 Amps N/A 210 Amps
260-EPR-21 N/A 3/0 N/A 19 N/A 25 N/A 12 N/A 0.470 Inches N/A 1.040 Inches N/A 1.150 Inches N/A 1.310 Inches N/A 1.410 Inches N/A 1588 Lbs N/A 1691 Lbs N/A 360 Amps N/A 275 Amps N/A 241 Amps
260-EPR-22 N/A 4/0 N/A 19 N/A 32 N/A 12 N/A 0.530 Inches N/A 1.100 Inches N/A 1.210 Inches N/A 1.370 Inches N/A 1.470 Inches N/A 1927 Lbs N/A 2034 Lbs N/A 415 Amps N/A 315 Amps N/A 276 Amps