800.342.7215
sales@buyawg.com
ISO 9001
Certified
Menu
Home
Products
Grounding, Static & Guy Wire
Transmission & Distribution Cables
Multiplex Cables
Low Voltage/PV Cables
Medium Voltage Cables
Armored Cables
Control Cables
OPGW / Fiber Optic Cables
Portable Power Cables
AWG Line Card
Ordering Info
How to Order
Terms & Conditions
Shipping Terms
Credit Application
Credit Card Form
Outlet Store
Reference
About
About AWG
Meet the AWG Team
Quality Process
Emergency Response
Survey
Download Catalogs
Complete Catalog
Utility Linecard
Solar Linecard
TE/Raychem Info
Contact Us
All Categories
>
Low Voltage Cables
>
Copper XLP UL XHHW-2 90°C 600V
>
XHHW-2 XLP Copper Conductor 600V, 90°C Wet or Dry
>
View Items
XHHW-2 XLP Copper Conductor 600V, 90°C Wet or Dry
Check up to five results to perform an action.
larger image
Applications
Single Conductor Cross linked polyethylene (XLP or XLPE) Type XHHW-2, intended for use at 600 volts or less. It is approved for general purpose lighting and power applications at a maximum continuous operating temperature of 90 ºC in wet or dry locations. VW-1 available where required.
Construction
Single copper conductors, solid or stranded annealed or hard uncoated copper per UL83 and ASTM requirements. Insulates with XLP as specified and applied tightly to the conductor in a concentric manner. The minimum at any point shall not be less than 90% of the specified average thickness in compliance with UL 44. Identified by surface marking indicating the manufacturer, conductor size, voltage rating, UL symbol, and type designation. Continuously spark tested at 7500 Volts DC and pass the 4 hour cold bend test of -25 ºC. Other electrical and mechanical tests shall be in accordance with UL 44 and UL 1581.
Standards
Underwriter's Laboratories UL 44
Canadian Standard C22.2 No. 38
Insulated Cable Engineers Association ICEA S-95-658
Institute of Electrical and Electronics Engineers IEEE 1202
Federal Specification A-A-59544
NEMA Publication No. WC-70
Gas and Oil Resistant II (UL)
Download PDF
Download PDF
Email This Page
Save To Favorites
Please wait…
Results Per Page :
25
50
100
200
Results 1 - 21 of 21
1
Item #
Size
AWG or MCM
Number
of
Strands
Insulation
Thickness
(mls)
Approximate O.D.
(Inches)
Copper Weight
(lbs. per MFT)
Shipping Weight
(lbs. per MFT)
Ampacity
90 ºC
Dry
XHHW-C14
14
7 / 19
30
0.140
12.7
18
15
XHHW-C12
12
7 / 19
30
0.160
20.2
27
20
XHHW-C10
10
7 / 19
30
0.180
32.1
41
30
XHHW-C8
8
7
45
0.240
51.0
67
55
XHHW-C6
6
7
45
0.280
81.1
100
75
XHHW-C4
4
7
45
0.330
128.9
153
95
XHHW-C3
3
7
45
0.349
162.5
190
110
XHHW-C2
2
7
45
0.390
204.9
236
130
XHHW-C1
1
19
55
0.450
258.4
292
150
XHHW-C1/0
1/0
19
55
0.490
325.8
363
170
XHHW-C2/0
2/0
19
55
0.535
410.9
452
195
XHHW-C3/0
3/0
19
55
0.590
518.1
562
225
XHHW-C4/0
4/0
19
55
0.645
653.3
702
260
XHHW-C250
250
37
65
0.715
771.9
831
290
XHHW-C300
300
37
65
0.770
926.3
1000
320
XHHW-C350
350
37
65
0.820
1081
1160
350
XHHW-C400
400
37
65
0.870
1235
1322
N/A
XHHW-C500
500
37
65
0.955
1544
1643
430
XHHW-C600
600
61
80
1.040
1853
1982
475
XHHW-C750
750
61
80
1.150
2316
2461
535
XHHW-C1000
1000
61
80
1.300
3008
3257
615
Results 1 - 21 of 21
1
Privacy
Site Map
Catalog Index
Site created by
Thomas Web Solutions
and Powered by
Navigator Platform
© 2021, American Wire Group