Low Voltage Cables
>
Copper UL RHH/RHW-2 or USE-2 90°C 600V and 2kV
>
CU UL RHH/RHW-2 USE-2 600V
>
USE-2 / RHH / RHW-2 EPR/CPE Copper Conductor 600V, 90°C Wet or Dry
>
View Items
USE-2 / RHH / RHW-2 EPR/CPE Copper Conductor 600V, 90°C Wet or Dry
Check up to five results to perform an action.
larger image
Applications
Recommended for use in all low voltage circuits where continuity of service is the prime consideration. These cables may be installed in wet or dry locations, indoors or outdoors, in raceways, underground ducts, directly buried in the earth, or lashed to a messenger for aerial installation. These cables may also be installed in cable tray (size 1/0 AWG and larger per NEC 392.2). For use in free air, raceways or direct burial in accordance with NEC.
Specifications
Conductor: Uncoated copper solid per ASTM-B-3, compress stranded per ASTM B-8, or compact per ASTM B-496. Insulation: Meets or exceeds all requirements of ICEA S-95-658/NEMA WC-70 and UL Standards 44 and 854. Jacket: CPE. Listed by Underwriters Laboratories, Inc. as Type RHH or RHW-2 or USE-2, VW-1. Sizes 1/0 AWG and larger are also marked "sunlight resistant, for use in cable tray." Listed by CSA as RW-90, -25C, FT1 (1/0 and larger FT4), outdoor.
Product Features
Sizes 1/0 AWG and larger pass the Vertical Tray Flame Test requirements of UL 1581 for use in cable tray.
Passes the IEEE 383-1974 Vertical Tray Flame Test.
Passes the IEEE 1202-1991 Vertical Tray Flame Test. (sizes 1/0 AWG & larger).
Extreme heat resistance; 90 ºC continuous rating, wet or dry 110 ºC hot spot rating 130 ºC emergency overload rating 250 ºC short circuit rating
Notes
These ampacities are based on single conductor in free air, 40 ºC ambient air temperature, 90 ºC conductor operating temperature.
Options
PVC or LSOH jacket
Download PDF
Download PDF
Email This Page
Save To Favorites
Please wait…
Results Per Page :
25
50
100
200
Results 1 - 15 of 15
1
Item #
Conductor
Size
AWG
MCM
(lb)
Conductor
Stranding
Conductor
Diameter
(in)
Nominal
Insulation
(in)
Nominal
Jacket
Thickness
Min.
(in)
Nominal
Jacket
Thickness
Min.
(mm)
Nominal
Jacket
Thickness
Approximate
(in)
Nominal
Jacket
Thickness
Approximate
(mm)
Nominal
Jacket
Thickness
Max.
(in)
Nominal
Jacket
Thickness
Max.
(mm)
Nominal
O.D.
(in)
Approximate
Weight
/MFT
Ampacity
40 ºC
Ambient
Temp.
USE2-14
14 AWG
7
0.072
0.03
0.161
4.1
0.165
4.2
0.177
4.5
0.236
24
25
USE2-12
12 AWG
7
0.091
0.03
0.185
4.7
0.189
4.8
0.205
5.2
0.256
34
32
USE2-10
10 AWG
7
0.116
0.03
0.205
5.2
0.213
5.4
0.228
5.8
0.29
49
47
USE2-8
8 AWG
7
0.146
0.045
0.268
6.8
0.276
7
0.299
7.6
0.333
79
83
USE2-6
6 AWG
7
0.183
0.045
0.335
8.5
0.346
8.8
0.374
9.5
0.403
124
109
USE2-4
4 AWG
7
0.231
0.045
0.382
9.7
0.394
10
0.425
10.8
0.461
179
145
USE2-2
2 AWG
7
0.292
0.045
0.441
11.2
0.453
11.5
0.488
12.4
0.51
260
192
USE2-1/0
1/0 AWG
19
0.373
0.055
0.559
14.2
0.575
14.6
0.622
15.8
0.7
420
258
USE2-2/0
2/0 AWG
19
0.419
0.055
0.602
15.3
0.619
15.73
0.669
17
0.74
513
298
USE2-4/0
4/0 AWG
19
0.528
0.055
0.717
18.2
0.736
18.7
0.795
20.2
0.87
774
400
USE2-250
250 MCM
37
0.575
0.065
0.827
21
0.85
21.6
0.917
23.3
0.99
956
445
USE2-350
350 MCM
37
0.681
0.065
0.929
23.6
0.957
24.3
1.031
26.2
1.055
1290
552
USE2-500
500 MCM
37
0.813
0.065
1.055
26.8
1.088
27.64
1.177
29.9
1.125
1798
695
USE2-750
750 MCM
61
0.98
0.08
1.264
32.1
1.303
33.1
1.406
35.7
1.205
2686
898
USE2-1000
1000 MCM
61
1.152
0.08
1.413
35.9
1.457
37
1.575
40
1.305
3463
1076
Results 1 - 15 of 15