ISO 9001:2008ISO 9001
Certified
A POWERFUL SOLUTION
All Categories > Control Cables & Portable Power Cables > Control Cables > Control Cable/Power Cable FR-XLPE > Control Cable/Power Cable FR-XLPE Insulated Conductors, XLPO Jacket, 600V > Control Cable FR-XLPE Insulated Conductors, XLPO Jacket, 600V > 12 AWG Control Cable FR-XLPE Insulated Conductors XLPO Jacket, 600V > View Items  

12 AWG Control Cable FR-XLPE Insulated Conductors XLPO Jacket, 600V

Check up to five results to perform an action.

Applications
As flame-retardant multi-conductor control, signal or power cables rated 600 volts, 90 ºC in wet or dry locations. Specifically approved for installation in cable trays per Article 336 of the NEC. Also approved for use in Class I remote-control and signaling circuits per Article 725 of the NEC. Type TC cable is suitable for use in Class I and II, Division 2 hazardous locations. Cables may be installed in air, in ducts or conduits, in tray or trough, and are suitable for direct burial.

Construction
Stranded uncoated copper conductors, FR-XLPE flame-retardant cross linked polyethylene insulation, color coded, two conductors flat, three or more conductors twisted with suitable fillers where necessary to make round, cable tape, XLPO jacket overall, surface printed.

Standards
  • Listed by UL as Type TC per Standard 1277 for Tray Cables.
  • Cables UL listed for Direct Burial.
  • Individual conductors pass UL VW-1 flame test.
  • Individual conductors UL listed as Type XHHW-2.
  • Overall jacket UL listed as Sunlight Resistant.
  • Cables with grounding conductor UL listed for Open Wiring.
  • Cables pass IEEE-383 ribbon burner flame test and ICEA 210,000 BTU/hour test.
  • Cables pass IEEE1202/CSA FT4 (70,000 BTU/hr) cable tray flame test.
  • Cables meet requirements of ICEA S-73-532, NEMA WC70 for Control Cables.
Notes
  • Cables may be supplied with an insulated ground and marked ""Open Wiring.""
  • Standard color coding is Method 1 for NEC applications per Appendix E, Table E-2 of ICEA S-73-532(TECH I006). This color coding method omits white and green from the color sequence. A white or green conductor can be supplied on request.
  • Color Coding also available ICEA Method 1, Table E-1; power sizes, ICEA Method 4.
Options
  • Bare or Tinned Copper
  • Flexible stranded conductors
  • E1 or E2 color codes
  • EPR Insulation
  • PVC, CPE, CSPE jackets
  • Overall copper tape shield
  • Overall copper braid shield
  • Overall longitudinal corrugated copper shield
  • Overall mylar tape shield with drain wire
  • 1000 volt rated construction
Consult AWG for a variety of alternate constructions for specific applications.





    Download PDF Download PDF   
    Email Email This Page  
    Save To Favorites Save To Favorites
  
   
  Results 1 - 12 of 12 1 

Item #

Number
of
Conductors

Conductor
Size
AWG

Conductor
Stranding

Insulation
Thickness

Nominal
Jacket
Thickness
(in)

Nominal
Jacket
Thickness
(mm)

Nominal
Cable
O.D.
(in)

Nominal
Cable
O.D.
(mm)

Approximate
Weight
/MFT
(lb)

Approximate
Cable
Weight
kg/km

12-R-XLPO-2 2 12 7 0.03 0.045 1.1 .255 x .415 6.48 x 11.4 92 136
12-R-XLPO-3 3 12 7 0.03 0.045 1.1 0.440 11.2 131 194
12-R-XLPO-4 4 12 7 0.03 0.045 1.1 0.485 12.3 164 243
12-R-XLPO-5 5 12 7 0.03 0.045 1.1 0.530 13.5 202 299
12-R-XLPO-7 7 12 7 0.03 0.060 1.5 0.610 15.5 283 419
12-R-XLPO-9 9 12 7 0.03 0.060 1.5 0.715 18.2 357 528
12-R-XLPO-12 12 12 7 0.03 0.060 1.5 0.795 20.2 462 684
12-R-XLPO-16 16 12 7 0.03 0.080 2 0.930 23.6 620 918
12-R-XLPO-19 19 12 7 0.03 0.080 2 0.975 24.8 710 1051
12-R-XLPO-26 26 12 7 0.03 0.080 2 1.160 29.5 950 1406
12-R-XLPO-30 30 12 7 0.03 0.080 2 1.200 30.5 1065 1576
12-R-XLPO-37 37 12 7 0.03 0.080 2 1.300 33.0 1285 1902
  Results 1 - 12 of 12 1 
Privacy     Site Map     Catalog IndexSite created by Thomas Web Solutions and Powered by Navigator Platform© 2021, American Wire Group