ISO 9001:2008ISO 9001
Certified
A POWERFUL SOLUTION
All Categories > Control Cables & Portable Power Cables > Control Cables > Control Cable/Power Cable FR-XLPE > Control Cable FR-XLPE Insulated Conductors, Copper Tape Shield, CPE Jacket, 600V > 12 AWG FR-XLPE Insulated Conductors CU Shield, CPE Jacket, 600V > View Items  

12 AWG FR-XLPE Insulated Conductors CU Shield, CPE Jacket, 600V

Check up to five results to perform an action.

Applications
Control or signal cable for important circuits in industrial plants and station control cable for electric utilities where flame resistance is essential. Suitable for the operation and interconnection of protective devices; rated circuit voltage 600 volts; recommended for operation at 90 ºC maximum continuous conductor temperature in wet or dry locations. Cables may be installed in open air, in ducts or conduits, in tray or trough, and are suitable for direct burial. Utility grade meets or exceeds all UL requirements.

Construction
Stranded coated copper conductors. The insulation shall be either fire retardant ethylene propylene rubber (EPR) or fire retardant cross-linked Polyethylene (FR-XLPE). ICEA Appendix E Method 1 color-coded, conductors twisted with suitable fillers, helically applied copper tape shield, CPE jacket overall, surface printed.

Standards
  • TC Type Tray Cable per Article 340 of the NEC.
  • Individual conductors pass UL Standard 44 and the VW-1 vertical flame test.
  • Individual conductors approved as Type XHHW.
  • Cables Pass IEEE-383 ribbon burner flame test.
  • Overall jacket approved as Sunlight Resistant.
  • Cables meet requirements of ICEA Pub. No. S-73-532/NEMA WC74
Notes
  • Cables may be supplied with an insulated ground and marked ""Open Wiring.""
  • Standard color coding is Method 1 for NEC applications per Appendix E, Table E-2 of ICEA S-73-532(TECH I006). This color coding method omits white and green from the color sequence. A white or green conductor can be supplied on request.
Options
  • Bare or Tinned Copper
  • Flexible stranded conductors
  • Color coding: ICEA Method 1, Table E1
  • EPR Insulation
  • PVC, CSPE, LSOH jackets
  • Insulated ground wires or bare ground wires
  • Overall copper tape shield
  • Overall copper braid shield
  • Overall longitudinal corrugated copper shield
  • Overall mylar tape shield with drain wire
  • 1000 volt rated construction
Consult AWG for a variety of alternate constructions for specific applications.





    Download PDF Download PDF   
    Email Email This Page  
    Save To Favorites Save To Favorites
  
   
  Results 1 - 20 of 20 1 

Item #

Number
of
Conductors

Conductor
Size AWG

Number
of
Strands

Overall Mils

Overall
Diameter
Inches
(mm)

12-452SH 2 12 7 45 0.49
12-453SH 3 12 7 45 0.54
12-454SH 4 12 7 60 0.62
12-455SH 5 12 7 60 0.67
12-456SH 6 12 7 60 0.70
12-457SH 7 12 7 60 0.73
12-458SH 8 12 7 60 0.86
12-462SH 12 12 7 80 0.95
12-464SH 14 12 7 80 1.04
12-465SH 15 12 7 80 1.20
12-466SH 16 12 7 80 1.22
12-468SH 18 12 7 80 1.25
12-469SH 19 12 7 80 1.25
12-470SH 20 12 7 80 1.31
12-475SH 25 12 7 80 1.39
12-477SH 27 12 7 80 1.41
12-479SH 29 12 7 80 1.42
12-481SH 31 12 7 80 1.44
12-482SH 32 12 7 80 1.47
12-487SH 37 12 7 80 1.53
  Results 1 - 20 of 20 1 
Privacy     Site Map     Catalog IndexSite created by Thomas Web Solutions and Powered by Navigator Platform© 2021, American Wire Group