800.342.7215
sales@buyawg.com
ISO 9001
Certified
Menu
Home
Products
Grounding, Static & Guy Wire
Transmission & Distribution Cables
Multiplex Cables
Low Voltage/PV Cables
Medium Voltage Cables
Armored Cables
Control Cables
OPGW / Fiber Optic Cables
Portable Power Cables
AWG Line Card
Ordering Info
How to Order
Terms & Conditions
Shipping Terms
Credit Application
Credit Card Form
Outlet Store
Reference
About
About AWG
Meet the AWG Team
Quality Process
Emergency Response
Survey
Download Catalogs
Complete Catalog
Utility Linecard
Solar Linecard
TE/Raychem Info
Contact Us
All Categories
>
Control Cables & Portable Power Cables
>
Control Cables
>
Control Cable/Power Cable FR-XLPE
>
Control Cable/Power Cable FR-XLPE Insulated Conductors, CPE Jacket, 600V
>
Control Cable FR-XLPE Insulated Conductors, CPE Jacket, 600V
>
12 AWG FR-XLP CPE Jacket, 600V
>
View Items
12 AWG FR-XLP CPE Jacket, 600V
Check up to five results to perform an action.
larger image
Applications
As flame-retardant multi-conductor control, signal or power cables rated 600 volts, 90 ºC in wet or dry locations. Specifically approved for installation in cable trays per Article 336 of the NEC. Also approved for use in Class I remote-control and signaling circuits per Article 725 of the NEC. Type TC cable is suitable for use in Class I and II, Division 2 hazardous locations. Cables may be installed in air, in ducts or conduits, in tray or trough, and are suitable for direct burial.
Construction
Stranded uncoated copper conductors, 30 mils FR-XLPE flame-retardant crosslinked polyethylene insulation, color coded, two conductors flat, three or more conductors twisted with suitable fillers where necessary to make round, cable tape, CPE jacket overall, surface printed.
Standards
Listed by UL as Type TC per Standard 1277 for Tray Cables.
Cables UL listed for Direct Burial.
Individual conductors pass UL VW-1 flame test.
Individual conductors UL listed as Type XHHW-2.
Overall jacket UL listed as Sunlight Resistant.
Cables with grounding conductor UL listed for Open Wiring.
Cables pass IEEE-383 ribbon burner flame test and ICEA 210,000 BTU/hour test.
Cables pass IEEE1202/CSA FT4 (70,000 BTU/hr) cable tray flame test.
Cables meet requirements of ICEA S-73-532, NEMA WC70 for Control Cables.
Notes
Cables may be supplied with an insulated ground and marked "Open Wiring."
Standard color coding is Method 1 for NEC applications per Appendix E, Table E-2 of ICEA S-73-532(TECH I006). This color coding method omits white and green from the color sequence. A white or green conductor can be supplied on request.
Color Coding also available ICEA Method 1, Table E-1; power sizes, ICEA Method 4.
Options
Bare or Tinned Copper
Flexible stranded conductors
E1 or E2 color codes
EPR Insulation
PVC, CSPE, LSOH jackets
Overall copper tape shield
Overall copper braid shield
Overall longitudinal corrugated copper shield
Overall mylar tape shield with drain wire
1000 volt rated construction
Consult AWG for a variety of alternate constructions for specific applications.
Download PDF
Download PDF
Email This Page
Save To Favorites
Please wait…
Results Per Page :
25
50
100
200
Results 1 - 13 of 13
1
Item #
No. of
Conductors
Size
AWG
Number
of
Strands
Nominal
Insulation
Thickness
(in)
Nominal
Insulation
Thickness
(mm)
Nominal
Jacket
Thickness
(in)
Nominal
Jacket
Thickness
(mm)
Nominal
Cable
O.D.
(in)
Nominal
Cable
O.D.
(mm)
Copper
Weight
lbs/MFT
Copper
Weight
kg/km
Approximate
Cable
Weight
/MFT
(lb)
Approximate
Cable
Weight
/MFT
(kg)
12-R-CPE-2-FLAT
2-Flat
12
7/.0305
0.030
0.76
0.045
1.14
.245x.400
6.22x10.16
40
60
86
128
12-R-CPE-2
2
12
7/.0305
0.030
0.76
0.045
1.14
0.410
10.410
41
61
96
143
12-R-CPE-3+GRND
3+Grnd
12
7/.0305
0.030
0.76
0.045
1.14
0.435
11.050
86
128
143
213
12-R-CPE-3
3
12
7/.0305
0.030
0.76
0.045
1.14
0.435
11.050
65
96
125
186
12-R-CPE-4
4
12
7/.0305
0.030
0.76
0.045
1.14
0.475
12.070
86
128
157
234
12-R-CPE-5
5
12
7/.0305
0.030
0.76
0.045
1.14
0.515
13.080
108
160
191
284
12-R-CPE-7
7
12
7/.0305
0.030
0.76
0.06
1.52
0.595
15.110
150
224
260
387
12-R-CPE-9
9
12
7/.0305
0.030
0.76
0.06
1.52
0.695
17.650
193
288
340
506
12-R-CPE-12
12
12
7/.0305
0.030
0.76
0.06
1.52
0.780
19.810
258
385
429
638
12-R-CPE-19
19
12
7/.0305
0.030
0.76
0.08
2.03
0.930
23.620
403
600
681
1013
12-R-CPE-25
25
12
7/.0305
0.030
0.76
0.08
2.03
1.095
27.810
515
767
885
1317
12-R-CPE-30
30
12
7/.0305
0.030
0.76
0.08
2.03
1.150
29.210
618
920
1005
1496
12-R-CPE-37
37
12
7/.0305
0.030
0.76
0.08
2.03
1.240
31.500
741
1103
1185
1764
Results 1 - 13 of 13
1
Privacy
Site Map
Catalog Index
Site created by
Thomas Web Solutions
and Powered by
Navigator Platform
© 2021, American Wire Group