Applications
Control or signal cable for important circuits in industrial plants and station control cable for electric utilities where flame resistance is essential. Suitable for the operation and interconnection of protective devices; rated circuit voltage 600 volts; recommended for operation at 90 ºC maximum continuous conductor temperature in wet or dry locations. Cables may be installed in open air, in ducts or conduits, in tray or trough, and are suitable for direct burial. Utility grade meets or exceeds all UL requirements.

Construction
Stranded coated copper conductors. The insulation shall be either fire retardant ethylene propylene rubber (EPR) or fire retardant cross-linked Polyethylene (FR-XLPE). ICEA Appendix E Method 1 color-coded, conductors twisted with suitable fillers, helically applied copper tape shield, CPE jacket overall, surface printed.

Standards
  • TC Type Tray Cable per Article 340 of the NEC.
  • Individual conductors pass UL Standard 44 and the VW-1 vertical flame test.
  • Individual conductors approved as Type XHHW.
  • Cables Pass IEEE-383 ribbon burner flame test.
  • Overall jacket approved as Sunlight Resistant.
  • Cables meet requirements of ICEA Pub. No. S-73-532/NEMA WC74
Notes
  • Cables may be supplied with an insulated ground and marked ""Open Wiring.""
  • Standard color coding is Method 1 for NEC applications per Appendix E, Table E-2 of ICEA S-73-532(TECH I006). This color coding method omits white and green from the color sequence. A white or green conductor can be supplied on request.
  • Color Coding also available ICEA Method 1, Table E-1; power sizes, ICEA Method 4.
Options
  • Bare or Tinned Copper
  • Flexible stranded conductors
  • Color coding: ICEA Method 1, Table E1
  • EPR Insulation
  • PVC, CSPE, LSOH jackets
  • Insulated ground wires or bare ground wires
  • Overall copper tape shield
  • Overall copper braid shield
  • Overall longitudinal corrugated copper shield
  • Overall Mylar tape shield with drain wire
  • 1000 volt rated construction
Consult AWG for a variety of alternate constructions for specific applications.





    Download PDF Download PDF   
    Email Email This Page  
    Save To Favorites Save To Favorites
  
   
  Results 1 - 33 of 33 1 

Item #

Number of
Conductors

Conductor
Size
AWG

Conductor
Stranding

Copper
Shield
Thickness
(in)

Copper
Shield
Thickness
(mm)

Nominal
Jacket
Thickness
(in)

Nominal
Jacket
Thickness
(mm)

Nominal
Cable
O.D.
(in)

Nominal
Cable
O.D.
(mm)

Approximate
Cable
Weight
/MFT(lb)

Approximate
Cable
Weight
/MFT(kb)

14-402ESH 2 14 7 0.005 0.13 0.045 1.1 0.445 11.30 109 162
14-403ESH 3 14 7 0.005 0.13 0.045 1.1 0.470 11.90 132 196
14-404ESH 4 14 7 0.005 0.13 0.045 1.1 0.505 12.80 155 231
14-405ESH 5 14 7 0.005 0.13 0.06 1.5 0.580 14.70 207 308
14-407ESH 7 14 7 0.005 0.13 0.06 1.5 0.620 15.70 246 366
14-409ESH 9 14 7 0.005 0.13 0.06 1.5 0.705 17.90 311 463
14-412ESH 12 14 7 0.005 0.13 0.06 1.5 0.785 19.90 393 585
12-452ESH 2 12 7 0.005 0.13 0.045 1.1 0.485 12.30 137 204
12-453ESH 3 12 7 0.005 0.13 0.045 1.1 0.510 13.00 163 243
12-454ESH 4 12 7 0.005 0.13 0.06 1.5 0.585 14.90 225 335
12-455ESH 5 12 7 0.005 0.13 0.06 1.5 0.630 16.00 259 385
12-457ESH 7 12 7 0.005 0.13 0.06 1.5 0.675 17.10 322 479
12-459ESH 9 12 7 0.005 0.13 0.06 1.5 0.775 19.70 409 609
12-462ESH 12 12 7 0.005 0.13 0.08 2 0.905 23.00 552 821
10-502ESH 2 10 7 0.005 0.13 0.045 1.1 0.535 13.60 179 266
10-503ESH 3 10 7 0.005 0.13 0.06 1.5 0.595 15.10 234 348
10-504ESH 4 10 7 0.005 0.13 0.06 1.5 0.640 16.30 289 430
10-505ESH 5 10 7 0.005 0.13 0.06 1.5 0.695 17.70 340 506
10-507ESH 7 10 7 0.005 0.13 0.06 1.5 0.750 19.10 442 658
10-509ESH 9 10 7 0.005 0.13 0.08 2 0.910 23.10 590 878
10-512ESH 12 10 7 0.005 0.13 0.08 2 1.010 25.70 748 1113
08-552ESH 2 8 7 0.005 0.13 0.06 1.5 0.695 17.70 288 429
08-553ESH 3 8 7 0.005 0.13 0.06 1.5 0.735 18.70 365 543
08-554ESH 4 8 7 0.005 0.13 0.06 1.5 0.795 20.20 444 661
06-602ESH 2 6 7 0.005 0.13 0.06 1.5 0.775 19.70 378 562
06-603ESH 3 6 7 0.005 0.13 0.06 1.5 0.820 20.80 494 735
04-502ESH 2 4 7 0.005 0.13 0.08 2 0.915 23.20 550 818
04-503ESH 3 4 7 0.005 0.13 0.08 2 0.965 24.50 722 1074
04-554ESH 4 4 7 0.005 0.13 0.08 2 1.055 26.80 903 1344
02-503ESH 2 2 7 0.005 0.13 0.08 2 1.035 26.30 758 1128
02-554ESH 3 2 7 0.005 0.13 0.08 2 1.100 27.90 1007 1498
01-503ESH 2 1 19 0.005 0.13 0.08 2 1.230 31.20 1236 1839
01-554ESH 3 1 19 0.005 0.13 0.08 2 1.350 34.30 1564 2327