800.342.7215
sales@buyawg.com
ISO 9001
Certified
Menu
Home
Products
Grounding, Static & Guy Wire
Transmission & Distribution Cables
Multiplex Cables
Low Voltage/PV Cables
Medium Voltage Cables
Armored Cables
Control Cables
OPGW / Fiber Optic Cables
Portable Power Cables
AWG Line Card
Ordering Info
How to Order
Terms & Conditions
Shipping Terms
Credit Application
Credit Card Form
Outlet Store
Reference
About
About AWG
Meet the AWG Team
Quality Process
Emergency Response
Survey
Download Catalogs
Complete Catalog
Utility Linecard
Solar Linecard
TE/Raychem Info
Contact Us
All Categories
>
Control Cables & Portable Power Cables
>
Control Cables
>
Control Cable/Power Cable EPR
>
Control Cable
EPR Insulated Conductors, CU Shield, CPE Jacket, 600V
>
Control Cable EPR Insulated Conductors, CU Shield, CPE Jacket, 600V
>
View Items
Control Cable EPR Insulated Conductors, CU Shield, CPE Jacket, 600V
Check up to five results to perform an action.
larger image
Applications
Control or signal cable for important circuits in industrial plants and station control cable for electric utilities where flame resistance is essential. Suitable for the operation and interconnection of protective devices; rated circuit voltage 600 volts; recommended for operation at 90 ºC maximum continuous conductor temperature in wet or dry locations. Cables may be installed in open air, in ducts or conduits, in tray or trough, and are suitable for direct burial. Utility grade meets or exceeds all UL requirements.
Construction
Stranded coated copper conductors. The insulation shall be either fire retardant ethylene propylene rubber (EPR) or fire retardant cross-linked Polyethylene (FR-XLPE). ICEA Appendix E Method 1 color-coded, conductors twisted with suitable fillers, helically applied copper tape shield, CPE jacket overall, surface printed.
Standards
TC Type Tray Cable per Article 340 of the NEC.
Individual conductors pass UL Standard 44 and the VW-1 vertical flame test.
Individual conductors approved as Type XHHW.
Cables Pass IEEE-383 ribbon burner flame test.
Overall jacket approved as Sunlight Resistant.
Cables meet requirements of ICEA Pub. No. S-73-532/NEMA WC74
Notes
Cables may be supplied with an insulated ground and marked ""Open Wiring.""
Standard color coding is Method 1 for NEC applications per Appendix E, Table E-2 of ICEA S-73-532(TECH I006). This color coding method omits white and green from the color sequence. A white or green conductor can be supplied on request.
Color Coding also available ICEA Method 1, Table E-1; power sizes, ICEA Method 4.
Options
Bare or Tinned Copper
Flexible stranded conductors
Color coding: ICEA Method 1, Table E1
EPR Insulation
PVC, CSPE, LSOH jackets
Insulated ground wires or bare ground wires
Overall copper tape shield
Overall copper braid shield
Overall longitudinal corrugated copper shield
Overall Mylar tape shield with drain wire
1000 volt rated construction
Consult AWG for a variety of alternate constructions for specific applications.
Download PDF
Download PDF
Email This Page
Save To Favorites
Please wait…
Results Per Page :
25
50
100
200
Results 1 - 33 of 33
1
Item #
Number of
Conductors
Conductor
Size
AWG
Conductor
Stranding
Copper
Shield
Thickness
(in)
Copper
Shield
Thickness
(mm)
Nominal
Jacket
Thickness
(in)
Nominal
Jacket
Thickness
(mm)
Nominal
Cable
O.D.
(in)
Nominal
Cable
O.D.
(mm)
Approximate
Cable
Weight
/MFT(lb)
Approximate
Cable
Weight
/MFT(kb)
14-402ESH
2
14
7
0.005
0.13
0.045
1.1
0.445
11.30
109
162
14-403ESH
3
14
7
0.005
0.13
0.045
1.1
0.470
11.90
132
196
14-404ESH
4
14
7
0.005
0.13
0.045
1.1
0.505
12.80
155
231
14-405ESH
5
14
7
0.005
0.13
0.06
1.5
0.580
14.70
207
308
14-407ESH
7
14
7
0.005
0.13
0.06
1.5
0.620
15.70
246
366
14-409ESH
9
14
7
0.005
0.13
0.06
1.5
0.705
17.90
311
463
14-412ESH
12
14
7
0.005
0.13
0.06
1.5
0.785
19.90
393
585
12-452ESH
2
12
7
0.005
0.13
0.045
1.1
0.485
12.30
137
204
12-453ESH
3
12
7
0.005
0.13
0.045
1.1
0.510
13.00
163
243
12-454ESH
4
12
7
0.005
0.13
0.06
1.5
0.585
14.90
225
335
12-455ESH
5
12
7
0.005
0.13
0.06
1.5
0.630
16.00
259
385
12-457ESH
7
12
7
0.005
0.13
0.06
1.5
0.675
17.10
322
479
12-459ESH
9
12
7
0.005
0.13
0.06
1.5
0.775
19.70
409
609
12-462ESH
12
12
7
0.005
0.13
0.08
2
0.905
23.00
552
821
10-502ESH
2
10
7
0.005
0.13
0.045
1.1
0.535
13.60
179
266
10-503ESH
3
10
7
0.005
0.13
0.06
1.5
0.595
15.10
234
348
10-504ESH
4
10
7
0.005
0.13
0.06
1.5
0.640
16.30
289
430
10-505ESH
5
10
7
0.005
0.13
0.06
1.5
0.695
17.70
340
506
10-507ESH
7
10
7
0.005
0.13
0.06
1.5
0.750
19.10
442
658
10-509ESH
9
10
7
0.005
0.13
0.08
2
0.910
23.10
590
878
10-512ESH
12
10
7
0.005
0.13
0.08
2
1.010
25.70
748
1113
08-552ESH
2
8
7
0.005
0.13
0.06
1.5
0.695
17.70
288
429
08-553ESH
3
8
7
0.005
0.13
0.06
1.5
0.735
18.70
365
543
08-554ESH
4
8
7
0.005
0.13
0.06
1.5
0.795
20.20
444
661
06-602ESH
2
6
7
0.005
0.13
0.06
1.5
0.775
19.70
378
562
06-603ESH
3
6
7
0.005
0.13
0.06
1.5
0.820
20.80
494
735
04-502ESH
2
4
7
0.005
0.13
0.08
2
0.915
23.20
550
818
04-503ESH
3
4
7
0.005
0.13
0.08
2
0.965
24.50
722
1074
04-554ESH
4
4
7
0.005
0.13
0.08
2
1.055
26.80
903
1344
02-503ESH
2
2
7
0.005
0.13
0.08
2
1.035
26.30
758
1128
02-554ESH
3
2
7
0.005
0.13
0.08
2
1.100
27.90
1007
1498
01-503ESH
2
1
19
0.005
0.13
0.08
2
1.230
31.20
1236
1839
01-554ESH
3
1
19
0.005
0.13
0.08
2
1.350
34.30
1564
2327
Results 1 - 33 of 33