Applications
Duplexed conductors are sunlight-resistant, photovoltaic wire rated 90ºC wet or dry, 2000 volts for interconnection wiring of grounded and ungrounded photovoltaic power systems as described in Section 690.31(A) and other applicable parts of the National Electrical Code (NEC), NFPA 70.  For use in free air, raceways or direct burial in accordance with NEC. 

Construction
Conductor: 8 AWG thru 1000 kcmil compact aluminum ACM (8000 series) conductors. Insulation is Flame-Retardant Cross-Linked Polyethylene (XLPE), black, suitable for 2000 V

Duplexing: One phase conductor is black, the other conductor is black with three white stripes. Conductors are pre-twisted together on reel

Features
  • Rated 90ºC wet and dry
  • Deformation-resistant at high temperatures
  • Excellent moisture resistance, exceeds UL 44
  • Stable electrical properties over a broad temperature range
  • Excellent resistance to crush and compression cuts
  • Resistant to most oils and chemicals
  • UV/sunlight-resistant
  • Meets cold bend test at -40ºC
  • Use Duplex SunGard to avoid mismatch of Positive and Negative sets
  • Reduce labor costs and equipment cost for laying cable in trench by deploying one reel, instead of two

Specifications

  • ASTM B800 - 05(2011) Standard Specification for 8000 Series Aluminum Alloy Wire for Electrical Purposes - Annealed and Intermediate Tempers
  • ASTM B801 - 07(2012) Standard Specification for Concentric-Lay-Stranded Conductors of 8000 Series Aluminum Alloy for Subsequent Covering or Insulation
  • ASTM B836 - 00(2011) Standard Specification for Compact Round Stranded Aluminum Conductors Using Single Input Wire Construction
  • UL 4703 Type PV
  • National Electrical Code (NEC)
  • ICEA S-95-658/NEMA WC70
  • UL 44 Type RHH or RHW-2
  • UL 854 Type USE-2
  • c(UL) RWU90 1kV

Other Compliances

  • EPA 40 CFR, Part 261 for leachable lead content per TCLP
  • OSHA Acceptable
  • RoHS Compliant, Sun Res, Gas and Oil Resistant II

Option
UL 1581 VW-1 compliance available on request
19 strand conductors available on request

Packaging: 
Material cut to length and shipped on non-returnable wood reels






    Download PDF Download PDF   
    Email Email This Page  
    Save To Favorites Save To Favorites
  
   
  Results 1 - 17 of 17 1 

Item #

Conductor
Size
(AWG/kcmil)

Single
Conductor
Stranding

Nominal
Conductor
OD
(in)

Minimum
Average
Insulation
Thickness
(in)

Duplexed
Cable
Diameter
(inches)

Aluminum
Weight
(lb/MFT)

Net
Weight
(lb/MFT)

A8-02PV2X0700 8 7/.0486 0.134 0.085 0.62 32 104
A6-02PV2X0700 6 7/.0612 0.169 0.085 0.69 50 134
A4-02PV2X0700 4 7/.0772 0.213 0.085 0.78 78 180
A2-02PV2X0700 2 7/.0974 0.268 0.085 0.89 126 244
A1-02PV2X1900 1 19/.0664 0.299 0.105 1.03 158 324
A1/0-02PV2X190 1/0 19/.0745 0.336 0.105 1.10 198 382
A2/0-02PV2X1900 2/0 19/.0837 0.376 0.105 1.18 250 450
A3/0-02PV2X1900 3/0 19/.0940 0.423 0.105 1.28 316 534
A4/0-02PV2X1900 4/0 19/.1055 0.475 0.105 1.38 398 638
A250-02PV2X3700 250 37/.0822 0.520 0.120 1.53 524 826
A300-02PV2X3700 300 37/.0900 0.570 0.120 1.63 564 890
A350-02PV2X3700 350 37/.0972 0.616 0.120 1.72 658 1,006
A400-02PV2X3700 400 37/.1040 0.659 0.120 1.81 752 1,122
A500-02PV2X3700 500 37/.1159 0.736 0.120 1.96 942 1,350
A600-02PV2X6100 600 61/.0992 0.813 0.135 2.18 1,130 1,636
A750-02PV2X6100 750 61/.1109 0.908 0.135 2.37 1,412 1,970
A1000-02PV2X6100 1000 61/.1280 1.060 0.135 2.67 1,828 2,470