Aluminum THHN/THWN-2 Power Cable Low Friction 600V

Check up to five results to perform an action.

Applications
Low friction type THHN or THWN-2 conductors are primarily used in conduit and cable trays for services, feeders, and branch circuits in commercial or industrial applications as specified in the National Electrical Code 2001.

When used as Type THHN, conductor is suitable for use in dry locations at temperatures not to exceed 90°C.  When used as Type THWN-2 or TWN75 conductor is suitable for use in wet or dry locations at temperatures not to exceed 90°C or not to exceed 75°C when exposed to oil or coolant.  Voltage rating for cable is 600V.
This product is designed to be installed without the application of pulling lubricant.

Construction
Conductor
: Compact stranded AA-8000 series aluminum conductor material  per ASTM B800, ASTM B801, ASTM B836, ASTM B901 (Single Input Wire), as applicable.

Insulation:  Low coefficient of friction, abrasion, moisture, and heat resistant polyvinyl chloride (PVC).
Jacket:  Low coefficient of friction, abrasion, moisture, and heat resistant nylon polyamide jacket.

Stocking most sizes in Black, Red, Blue, White, Green, Brown, Orange, Yellow, and Gray

Standards

  • UL standard UL-83, UL-758, UL-1063, UL-1581, UL-2556
  • Complies with UL's VW-1 (vertical wire) Flame Test.
  • 1/0 & larger are rated for CT use
  • Meets the requirements of the NEC.
  • NEMA WC-70 construction requirements
  • Federal Specification AA-59544.
  • Sunlight Resistant in all color sizes 6AWG and larger.
  • RoHS Compliant

Packaging

  • 250 ft  reels
  • 500 ft reels
  • 1000 ft reels
  • Master reels
  • Coils

Ampacity 
* Ampacities for not more than three conductors in raceway, based on ambient temperature of 30ºC per Table 310-15 of the 2011 NEC. 

To determine correct ampacity by conductor size, please consult the National Electric Code, latest edition.

 






    Download PDF Download PDF   
    Email Email This Page  
    Save To Favorites Save To Favorites
  
   
  Results 1 - 19 of 19 1 

Item #

Size
AWG/MCM

Stranding

Conductor
Diameter
(inches)

Insulation
Thickness
(Inches)

Jacket
Thickness
(inches)

Outside
Diameter
(inches)

Weight
LBS/MFT

Ampacity
90ºC
(amps)

A8-01THHN 8 7 0.134 0.03 0.005 0.204 30 45
A6-01THHN 6 7 0.169 0.03 0.005 0.239 42 60
A4-01THHN 4 7 0.213 0.04 0.006 0.305 68 75
A2-01THHN 2 7 0.268 0.04 0.006 0.360 86 100
A1-01THHN 1 18 0.299 0.05 0.007 0.413 110 115
A1/0-01THHN 1/0 18 0.335 0.05 0.007 0.450 134 135
A2/0-01THHN 2/0 18 0.378 0.05 0.007 0.490 163 150
A3/0-01THHN 3/0 18 0.423 0.05 0.007 0.537 200 175
A4/0-01THHN 4/0 18 0.476 0.05 0.007 0.589 247 205
A250-01THHN 250 35 0.520 0.06 0.008 0.656 296 230
A300-01THHN 300 35 0.571 0.06 0.008 0.706 359 255
A350-01THHN 350 35 0.614 0.06 0.008 0.752 401 280
A400-01THHN 400 35 0.657 0.06 0.008 0.795 453 305
A500-01THHN 500 35 0.736 0.06 0.008 0.872 556 350
A600-01THHN 600 58 0.816 0.07 0.009 0.971 679 385
A700-01THHN 700 58 0.877 0.07 0.009 1.035 782 420
A750-01THHN 750 58 0.909 0.07 0.009 1.066 833 435
A900-01THHN 900 58 0.999 0.07 0.009 1.139 987 480
A1000-01THHN 1000 58 1.059 0.07 0.009 1.218 1090 500