All Categories > Control Cables & Portable Power Cables > Control Cables > IMSA Traffic Signal Cable > IMSA Cable Selection Guide > View Items  

IMSA Cable Selection Guide

Check up to five results to perform an action.






    Download PDF Download PDF   
    Email Email This Page  
    Save To Favorites Save To Favorites
  
   
  Results 1 - 37 of 37 1 

Item #

IMSA
SPEC NO.

VOLTAGE RATING

APPLICATIONS

INSTALLATION

CONDUCTOR CONFIGURATION

MECHANICAL CHARACTERISTICS

19-1 19-1 600 Traffic Signal, Fire Protective Signal Aerial or Duct Cabled Conductors PVC Outer Jacket
19-2 19-2 600 Traffic Signal, Fire Protective Signal Aerial or Duct Twisted Pairs Shielded, PVC Outer Jacket
19-3 19-3 600 Traffic Signal, Fire Protective Signal Figure-8 Aerial, Integral Msgr. Cabled Conductors PVC Outer Jacket
19-4 19-4 600 Traffic Signal, Fire Protective Signal Figure-8 Aerial, Integral Msgr. Twisted Pairs Shielded, PVC Outer Jacket
19-5 19-5 600 Traffic Signal, Fire Protective Signal Aerial, Duct or Buried Cabled Conductors Shielded, PE Inner & PVC Outer Jackets
16-6 19-6 600 Traffic Signal, Fire Protective Signal Aerial, Duct or Buried Twisted Pairs Shielded, PE Inner & PVC Outer Jackets
20-1 19-2 600 Traffic Signal, Fire Protective Signal Aerial or Duct Cabled Conductors PE Outer Jacket
20-2 19-3 600 Traffic Signal, Fire Protective Signal Aerial or Duct Twisted Pairs Shielded, PE Outer Jacket
20-3 19-4 600 Traffic Signal, Fire Protective Signal Figure-8 Aerial, Integral Msgr. Cabled Conductors PE Outer Jacket
20-4 19-5 600 Traffic Signal, Fire Protective Signal Figure-8 Aerial, Integral Msgr. Twisted Pairs Shielded, PE Outer Jacket
20-5 19-6 600 Traffic Signal, Fire Protective Signal Aerial, Duct or Buried Cabled Conductors Shielded, PE Inner & Outer Jacket
20-6 20-6 600 Traffic Signal, Fire Protective Signal Aerial, Duct or Buried Twisted Pairs Shielded, PE Inner & Outer Jacket
26-3 26-3 - Signal Systems Aerial Self-Supporting Single Hard-Drawn Copper Conductor High Density Polyethylene (HDPE) Insulation
28-3 28-3 - Signal Systems Aerial Self-Supporting Single Copper-Covered Steel Conductor HDPE Insulation
29-1 29-1 - Signal Systems Aerial Self-Supporting "C" Line Wire (Parallel) 2 Hard-Drawn Copper Conductors HDPE Insulation
29-2 28-3 - Signal Systems Aerial Self-Supporting "C" Line Wire (Parallel) 2 Copper-Covered Steel Conductors HDPE Insulation
29-3 29-3 - Signal Systems Aerial Self-Supporting "C" Line Wire (Parallel) 2 Hard-Drawn Copper Conductors HDPE Insulation PVC Outer Jacket
29-4 29-4 - Signal Systems Aerial Self-Supporting "C" Line Wire (Parallel) 2 Copper-Covered Steel Conductors HDPE Insulation PVC Outer Jacket
39-2 39-2 300 Fire Protective Signal, Traffic Communications, Data Acquisition Aerial, Duct or Building Raceway Twisted Pairs Shielded, PVC Outer Jacket
39-4 39-4 300 Traffic Communications, Data Acquisition Figure-8 Aerial, Integral Msgr. Twisted Pairs Shielded, PVC Outer Jacket
39-6 39-6 300 Fire Protective Signal, Traffic Communications, Data Acquisition Aerial, Duct or Building Raceway Twisted Pairs Shielded, PE Inner & PVC Outer Jackets
40-2 40-2 300 Fire Protective Signal, Traffic Communications, Data Acquisition Aerial, Duct or Building Raceway Twisted Pairs Shielded, PE Outer Jacket
40-4 40-4 300 Traffic Communications, Data Acquisition Figure-8 Aerial, Integral Msgr. Twisted Pairs Shielded, PE Outer Jacket
40-6 40-6 300 Fire Protective Signal, Traffic Communications, Data Acquisition Aerial, Duct, Buried or Building Raceway Twisted Pairs Shielded, PE Inner & Outer Jacket
50-2 50-2 600 Signal Loop Detector Lead-In Feeder Duct or Buried Twisted Pair PE Insulation, PE Outer Jacket
51-1 50-2 600 Inductance Loop Detector Duct Single Conductor PVC/Nylon Insulation
51-3 51-3 600 Inductance Loop Detector Duct or Buried Single Conductor Cross Linked PE Insulation
51-5 51-5 600 Inductance Loop Detector Duct or Buried Single Conductor PVC/Nylon Insulation in PVC or PE Tube
51-7 51-7 600 Inductance Loop Detector Duct or Buried Single Conductor Cross Linked PE Insulation in PVC or PE Tube
59-2 59-2 300 Fire Protective Signal, Traffic Communications, Data Acquisition Aerial or Duct Twisted Pairs Filled Core, Shielded, PVC Outer Jacket
59-4 59-4 300 Traffic Communications, Data Acquisition Figure-8 Aerial, Integral Msgr. Twisted Pairs Filled Core, Shielded, PVC Outer Jacket
59-6 59-6 300 Fire Protective Signal, Traffic Communications, Data Acquisition Aerial, Duct or Buried Twisted Pairs Filled Core, Shielded, PE Inner Jacket, PVC Outer Jacket
60-2 60-2 300 Fire Protective Signal, Traffic Communications, Data Acquisition Aerial or Duct Twisted Pairs Filled Core, Shielded, PE Outer Jacket
60-4 60-4 300 Traffic Communications, Data Acquisition Figure-8 Aerial, Integral Msgr. Twisted Pairs Filled Core, Shielded, PE Outer Jacket
60-6 60-6 300 Fire Protective Signal, Traffic Communications, Data Acquisition Aerial, Duct or Buried Twisted Pairs Filled Core, Shielded, PE Inner and PE Outer Jacket
70-1 70-1 - Traffic Communications Aerial, Duct or Buried 2 to 72 fibers All Dielectric
70-5 70-5 - Traffic Communications Duct or Buried 2 to 72 fibers Armored