ISO 9001:2008ISO 9001
Certified
A POWERFUL SOLUTION
All Categories > Transmission & Distribution Cables > PowerGuard® MV Aerial Cable (Spacer Cable or Tree Wire) > 15-25-35kV PowerGuard® MV Aerial 3 Layer Cable (Spacer Cable or Tree Wire) > 15kV PowerGuard® MV Aerial 3 Layer Cable (Spacer Cable or Tree Wire) - AAC > 15kV PowerGuard® MV Aerial 3 Layer Cable (Spacer Cable or Tree Wire) - AAC > View Items  

15kV PowerGuard® MV Aerial 3 Layer Cable (Spacer Cable or Tree Wire) - AAC

Check up to five results to perform an action.

Application
Used for primary and secondary overhead distribution where limited space is available or desirable for rights of way. Installed as an uninsulated conductor; however, covering is effective in preventing direct shorts and instantaneous flashovers should tree limbs or other objects contact conductors in such close proximity. The resulting close-proximity configuration minimizes the amount of space and hardware required for line installation; particularly useful in congested areas such as alleyways or tight corridors.

Construction
Conductors are concentric strand AAC (1350-H19), AAAC (either compressed or full compact depending on conductor size) or ACSR. The conductor shield shall be an extruded back semiconductor polymer meeting the physical requirements of ICEA S-61-402.  Available with track-resistant high-density polyethylene (TR-HDPE) per ASTM D1248 or Track-Resistant Cross-linked Polyethylene (TK-XLPE) covering per ASTM D2656 and ICEA S-66-524.  The minimum thickness of each layer at any point shall not be less than listed in the data table.   The outer layer shall contain a carbon black additive, not less than 0.02% to provide the weather resistance, and track resistance. 

Specification
15kV - 35kV PowerGuard® MV Aerial Cable meets or exceeds all applicable ICEA specifications and the following ASTM specifications:

  • ASTM B230 Standard Specification for Aluminum 1350–H19 Wire for Electrical Purposes
  • ASTM B231 Standard Specification for Concentric-Lay-Stranded Aluminum 1350 Conductors
  • ASTM B232 Standard Specification for Concentric-Lay-Stranded Aluminum Conductors, Coated-Steel Reinforced (ACSR) 
  • ASTM B398 Standard Specification for Aluminum-Alloy 6201-T81 and 6201-T83 Wire for Electrical Purposes
  • ASTM B399 Standard Specification for Concentric-Lay-Stranded Aluminum-Alloy 6201-T81 Conductors
  • ASTM B400 Standard Specification for Compact Round Concentric-Lay-Stranded Conductors
  • ASTM D2656 Standard Specification for Cross-linked Polyethylene Insulation for Wire and Cable Rated 2001 to 35 000 V
  • ASTM D1248 Standard Specification for Polyethylene Plastics Extrusion Materials for Wire and Cable
  • ICEA S-70-547 Standard Specification for Weather Resistant Polyethylene Covered Conductors

NOTES:
Full hardware solution is available, including spacers, brackets, installation tools and hardware.  Please consult with AWG for more information.  





    Download PDF Download PDF   
    Email Email This Page  
    Save To Favorites Save To Favorites
  
   
  Results 1 - 11 of 11 1 

Item #

Size
(AWG or kcmil)

Stranding

Conductor
Diameter
(mils)

Covering
Thickness
Conductor
Shield
(mils)

Covering
Thickness
Inner
Layer
(mils)

Covering
Thickness
Outer
Layer
(mils)

Cable
O.D.
(mils)

Rated
Strength
(lbs)

Weight
(lb/MFT)

TW15-3-AAC-1/0-7 1/0 7 336 15 75 75 666 1791 210
TW15-3-AAC-2/0-7 2/0 7 376 15 75 75 706 2259 246
TW15-3-AAC-3/0-7 3/0 7 423 15 75 75 753 2736 289
TW15-3-AAC-4/0-7 4/0 7 475 15 75 75 805 3447 343
TW15-3-AAC-266.8-19 266.8 19 537 15 75 75 867 4473 407
TW15-3-AAC-336.4-19 336.4 19 603 15 75 75 933 5535 487
TW15-3-AAC-397.5-19 397.5 19 659 15 75 75 989 6399 558
TW15-3-AAC-477-19 477 19 722 15 75 75 1052 7524 648
TW15-3-AAC-556.5-37 556.5 37 780 20 75 75 1120 8946 742
TW15-3-AAC-636-37 636 37 835 20 80 80 1195 10260 846
TW15-3-AAC-795-37 795 37 932 20 80 80 1292 12510 1020
  Results 1 - 11 of 11 1 