ISO 9001:2008ISO 9001
Certified
A POWERFUL SOLUTION
Application
Used for primary and secondary overhead distribution where limited space is available or desirable for rights of way. Installed as an uninsulated conductor; however, covering is effective in preventing direct shorts and instantaneous flashovers should tree limbs or other objects contact conductors in such close proximity. The resulting close-proximity configuration minimizes the amount of space and hardware required for line installation; particularly useful in congested areas such as alleyways or tight corridors.

Construction
Conductors are concentric strand AAC (1350-H19), AAAC (either compressed or full compact depending on conductor size) or ACSR. The conductor shield shall be an extruded back semiconductor polymer meeting the physical requirements of ICEA S-61-402.  Available with track-resistant high-density polyethylene (TR-HDPE) per ASTM D1248 or Track-Resistant Cross-linked Polyethylene (TK_XLPE) covering per ASTM D2656 and ICEA S-66-524.  The minimum thickness of each layer at any point shall not be less than listed in the data table.   The outer layer shall contain a carbon black additive, not less than 0.02% to provide the weather resistance, and track resistance. 

Specification
15kV - 35kV Covered Aerial Medium Voltage Cable wire meets or exceeds all applicable ICEA specifications and the following ASTM specifications:

  • ASTM B230 Standard Specification for Aluminum 1350–H19 Wire for Electrical Purposes
  • ASTM B231 Standard Specification for Concentric-Lay-Stranded Aluminum 1350 Conductors
  • ASTM B232 Standard Specification for Concentric-Lay-Stranded Aluminum Conductors, Coated-Steel Reinforced (ACSR) 
  • ASTM B398 Standard Specification for Aluminum-Alloy 6201-T81 and 6201-T83 Wire for Electrical Purposes
  • ASTM B399 Standard Specification for Concentric-Lay-Stranded Aluminum-Alloy 6201-T81 Conductors
  • ASTM B400 Standard Specification for Compact Round Concentric-Lay-Stranded Conductors
  • ASTM D2656 Standard Specification for Cross-linked Polyethylene Insulation for Wire and Cable Rated 2001 to 35 000 V
  • ASTM D1248 Standard Specification for Polyethylene Plastics Extrusion Materials for Wire and Cable
  • ICEA S-70-547 Standard Specification for Weather Resistant Polyethylene Covered Conductors

NOTES:
Full hardware solution is available, including spacers, brackets, installation tools and hardware.  Please consult with AWG for more information.  
1 - 10 of 10 | Results Per Page | View |
1 

Item #

Size
(AWG
or
kcmil)

Stranding

Conductor
Diameter
(mils)

Covering
Thickness
Inner
Layer
(mils)

Covering
Thickness
Outer
Layer
(mils)

Cable
O.D.
(mils)

Rated
Strength
(lbs)

Weight
(lb/MFT)

N/A 1/0 N/A 7 N/A 336 N/A 75 N/A 75 N/A 636 N/A 1791 N/A 196
N/A 2/0 N/A 7 N/A 376 N/A 75 N/A 75 N/A 676 N/A 2259 N/A 230
N/A 3/0 N/A 7 N/A 423 N/A 75 N/A 75 N/A 723 N/A 2736 N/A 272
N/A 4/0 N/A 7 N/A 475 N/A 75 N/A 75 N/A 775 N/A 3447 N/A 325
N/A 266.8 N/A 19 N/A 537 N/A 75 N/A 75 N/A 837 N/A 4473 N/A 387
N/A 336.4 N/A 19 N/A 603 N/A 75 N/A 75 N/A 903 N/A 5535 N/A 466
N/A 397.5 N/A 19 N/A 659 N/A 75 N/A 75 N/A 959 N/A 6399 N/A 535
N/A 477 N/A 19 N/A 722 N/A 75 N/A 75 N/A 1022 N/A 7524 N/A 623
N/A 556.5 N/A 37 N/A 780 N/A 75 N/A 75 N/A 1080 N/A 8946 N/A 708
N/A 636 N/A 37 N/A 835 N/A 75 N/A 75 N/A 1135 N/A 10260 N/A 794
1 - 10 of 10 | Results Per Page | View |