PowerGuard® 35kV MV Aluminum TR-XLPE Collection System Cable LLDPE Jacket UL MV-90/AEIC CS8-07
>
PowerGuard® 35kV 133% MV Aluminum 420 Mil TR-XLPE Collection System Cable LLDPE Jacket UL MV-90/AEIC CS8-07
>
PowerGuard® 35kV 133% MV 420 Mil TR-XLPE AL Collection System Cable LLDPE Jacket Concentric Neutral UL MV-90/AEIC CS8-07 -
PHYSICAL PROPERTIES (COMPRESSED)
>
View Items
PowerGuard® 35kV 133% MV 420 Mil TR-XLPE AL Collection System Cable LLDPE Jacket Concentric Neutral UL MV-90/AEIC CS8-07 -
PHYSICAL PROPERTIES (COMPRESSED)
Check up to five results to perform an action.
larger image
Applications
PowerGuard® cables are intended for use in wet or dry locations for distribution of single or three phase medium-voltage power. These cables may be installed in ducts or direct buried.
Description
Single conductor cable with filled strand aluminum conductors, triple extruded dry cured insulation system consisting of a thermosetting semiconducting conductor shield, high dielectric strength
PowerGuard®
TRXLPE insulation, thermosetting semiconducting insulation shield, copper concentric neutral wires, water blocking agents, black encapsulating linear low-density polyethylene (LLDPE) jacket.
Designed for 40 years service.
Construction
Conductor:
Class B compressed concentric stranded aluminum alloy 1350. Stranded conductors are water-blocked with conductor filling compound.
Conductor Shield:
Extruded thermosetting semiconducting shield which is free stripping from the conductor and bonded to the insulation.
Insulation:
Extruded, Tree-Retardant Cross-linked Polyethylene (TRXLPE) as defined in ANSI/ICEA S-94-649 - 133% insulation level.
Insulation Shield:
Extruded thermosetting semiconducting shield with controlled adhesion to the insulation providing the required balance between electrical integrity and ease of stripping.
Metallic Shield:
Solid bare copper wires helically applied and uniformly spaced.
Water Block:
Water-blocking agents applied over the insulation shield and around the neutral wires to resist longitudinal water penetration. Longitudinal water penetration shall be tested in accordance with the latest edition of ICEA T-34-664 except that the minimum requirements are 15 psig for 1 hour.
Jacket:
Black insulating sunlight resistant linear low-density polyethylene encapsulating the neutral wires with three extruded red stripes and NESC lightning bolt symbol.
Insulation Temperature Rating
Normal
90º C
Emergency*
130 ºC
Short Circuit - Shield
200º C
Short Circuit - Conductor
250º C
*Operation at the emergency overload temperature shall not exceed 1500 hours cumulative during the lifetime of the cable.
Specifications
ASTM B-231 (Compact) or ASTM B-400 (Compressed)
AEIC CS8
ICEA S-94-649
ICEA T-31-610
ICEA T-34-664 as applicable for TRXLPE insulated concentric neutral cable
UL 1072 MV-90
CSA Standard C68.5-07 File # 257759 Primary Shielded and Concentric Neutral Cable for Distribution
Options
Copper Conductors
Black LLDPE jacket with no stripes
Multiplex cables
NOTES:
Diameters are based on ASTM Class B Compressed diameters.
Extruded layer thicknesses, insulation and insulation shield diameters are in accordance with ANSI/ICEA S-94-649 for Concentric Neutral Cables Rated 5-46kV and also meet the requirements of the latest revisions of AEIC CS8. Dimensions and weights not designated as minimum or maximum are nominal values and are subject to manufacturing tolerances.
Download PDF
Download PDF
Email This Page
Save To Favorites
Please wait…
Results Per Page :
25
50
100
200
Results 1 - 42 of 42
1
Item #
Cond.
Size
AWG
or
kcmil
Neutral
Size
No.
of
Wires
Size
of
Wires
Nominal
Diameter
(inches)
Minimum
Insulation
Diameter
(Inches)
Maximum
Insulation
Diameter
(Inches)
Nominal
Jacket
Diameter
(Inches)
Aluminum
Cond.
Lbs/MFT
Copper
Neutral
Wires
Lbs/MFT
Total
Weight
Lbs/MFT
A1/0-01UD35UT100
1/0
Full
16
14
0.362
1.20
1.30
1.56
99
209
1,115
A1/0-01UD35UT203
1/0
2/3
11
14
0.362
1.20
1.30
1.56
99
144
1,026
A1/0-01UD35UT102
1/0
1/2
8
14
0.362
1.20
1.30
1.56
99
104
991
A1/0-01UD35UT103
1/0
1/3
6
14
0.362
1.20
1.30
1.56
99
78
979
A2/0-01UD35UT100
2/0
Full
20
14
0.408
1.24
1.34
1.60
125
266
1,198
A2/0-01UD35UT203
2/0
2/3
14
14
0.408
1.24
1.34
1.60
125
187
1,113
A2/0-01UD35UT102
2/0
1/2
10
14
0.408
1.24
1.34
1.60
125
133
1,055
A2/0-01UD35UT103
2/0
1/3
7
14
0.408
1.24
1.34
1.60
125
93
1,040
A3/0-01UD35UT100
3/0
Full
16
12
0.458
1.29
1.53
1.71
157
332
1,452
A3/0-01UD35UT203
3/0
2/3
17
14
0.458
1.29
1.53
1.65
157
222
1,274
A3/0-01UD35UT102
3/0
1/2
13
14
0.458
1.29
1.53
1.65
157
170
1,160
A3/0-01UD35UT103
3/0
1/3
9
14
0.458
1.29
1.53
1.65
157
118
1,152
A4/0-01UD35UT100
4/0
Full
20
12
0.515
1.35
1.45
1.75
198
415
1,622
A4/0-01UD35UT203
4/0
2/3
21
14
0.515
1.35
1.45
1.73
198
274
1,429
A4/0-01UD35UT102
4/0
1/2
16
14
0.515
1.35
1.45
1.73
198
209
1,374
A4/0-01UD35UT103
4/0
1/3
11
14
0.515
1.35
1.45
1.73
198
144
1,310
A4/0-01UD35UT103
4/0
1/6
6
14
0.515
1.35
1.45
1.73
198
78
1,244
A250-01UD35UT103
250
1/3
13
14
0.561
1.39
1.49
1.77
234
170
1,415
A250-01UD35UT106
250
1/6
10
16
0.561
1.39
1.49
1.75
234
84
1,304
A250-01UD35UT112
250
1/12
6
16
0.561
1.39
1.49
1.75
234
51
1,260
A350-01UD35UT100
350
Full
16
9
0.661
1.50
1.60
2.05
328
667
2,431
A350-01UD35UT203
350
2/3
22
12
0.661
1.50
1.60
1.96
328
458
2,068
A350-01UD35UT102
350
1/2
17
12
0.661
1.50
1.60
1.96
328
354
1,955
A350-01UD35UT103
350
1/3
18
14
0.661
1.50
1.60
1.92
328
235
1,777
A350-01UD35UT106
350
1/6
9
14
0.661
1.50
1.60
1.92
328
117
1,657
A350-01UD35UT112
350
1/12
7
16
0.661
1.50
1.60
1.89
328
59
1,532
A500-01UD35UT203
500
2/3
20
10
0.79
1.63
1.73
2.13
469
662
2,660
A500-01UD35UT102
500
1/2
24
12
0.79
1.63
1.73
2.10
469
498
2,419
A500-01UD35UT103
500
1/3
16
12
0.79
1.63
1.73
2.10
469
332
2,261
A500-01UD35UT106
500
1/6
13
14
0.79
1.63
1.73
2.07
469
170
2,036
A500-01UD35UT112
500
1/12
10
16
0.79
1.63
1.73
2.04
469
84
1,987
A750-01UD35UT102
750
1/2
23
10
0.968
1.82
1.92
2.35
703
761
3,326
A750-01UD35UT103
750
1/3
24
12
0.968
1.82
1.92
2.31
703
498
2,969
A750-01UD35UT103
750
1/6
19
14
0.968
1.82
1.92
2.29
703
248
2,638
A750-01UD35UT112
750
1/12
10
14
0.968
1.82
1.92
2.29
703
133
2,532
A1000-01UD35UT102
1000
1/2
30
10
1.117
1.97
2.07
2.51
937
993
4,038
A1000-01UD35UT103
1000
1/3
20
10
1.117
1.97
2.07
2.51
937
660
3,677
A1000-01UD35UT106
1000
1/6
16
12
1.117
1.97
2.07
2.47
937
332
3,242
A1000-01UD35UT112
1000
1/12
13
14
1.117
1.97
2.07
2.42
937
173
2,994
A1250-01UD35UT103
1250
1/3
25
10
1.25
2.11
2.21
2.80
1,173
827
4,580
A1250-01UD35UT106
1250
1/6
20
12
1.25
2.11
2.21
2.69
1,173
415
3,933
A1250-01UD35UT112
1250
1/12
16
14
1.25
2.11
2.21
2.64
1,173
209
3,640
Results 1 - 42 of 42