ISO 9001:2008ISO 9001
Certified
A POWERFUL SOLUTION
Applications
For use on single phase and three phase primary underground distribution systems operating at 15 kV phase to phase at 100 % and 133 % insulation level. Suitable for either direct burial or installation in ducts.

Construction
Copper concentrically stranded compressed conductor, triple single head extruded conductor shield, TRXLPE (tree-retardant cross-linked polyethylene) insulation and easy strippable insulation shield, all dry cured; solid bare copper wires uniformly spaced around the cable as a concentric neutral; LLDPE jacket with extruded longitudinal colored stripes, surface printed.

Standards
  • AEIC CS8 Specification for Extruded Dielectric Shielded Power Cables Rated 5 through 46 kV
  • ICEA S-94-649 Standard for Concentric Neutral Cables Rated 5,000 - 46,000V
  • ICEA T-31-610 Guide for Conducting a Longitudinal Water Penetration Resistance Tests on Blocked Conductors
  • ICEA T-34-664 Test Method for Conducting Longitudinal Water Penetration Resistance Tests on Longitudinal Water Blocked Cables
  • UL-1072 MV90
Options
  • EPR insulation
  • Filled strand
  • Cable core water blocking
Notes
  • Ampacities are based on the NEC.
  • Cable Tray: Three single cables, installed in uncovered cable tray in accordance with NEC Section 392.13; operating at 105 ºC conductor, at an ambient temperature of 40 ºC.
  • Buried Duct: Three cables per duct operating at 105 ºC conductor, 20 ºC ground ambient, earth ρ = 90, 100% load factor.
  • Conduit in Air: Three cables per isolated conduit in air at 40 ºC operating at 105 ºC conductor (NEC Table 310.73).
  • Maximum conductor temperature: 90 ºC normal continuous, 130 ºC overload, 250 ºC short circuit.
Unit of Measure

Specifications

Conductor
Size AWG

N/A 500

Conductor
Stranding

N/A 37

Copper
Neutral
No. of
Wires

N/A 17

Copper
Neutral
Size
AWG

N/A 10

Conductor
Diameter

N/A 0.789 Inches

Diameter
Over
Insulation

N/A 1.300 Inches

Diameter
Over
Insulation
Shield

N/A 1.420 Inches

Diameter
Over
Neutral
Wires

N/A 1.624 Inches

Diameter
Over
Embedded
Jacket

N/A 1.784 Inches

Total w/o Jacket Weight

N/A 2754 Lbs

Total w/ Embedded Jacket Weight

N/A 2924 Lbs

Ampacity
3/C
Direct Buried

N/A 525 Amps

Ampacity
3/C
Triplex Buried

N/A 480 Amps

Ampacity
3/C
Duct In Air

N/A 420 Amps
FacebookTweeterLinkedInYouTube