    Applications
    To supply power from the utility's lines to the consumer's weatherhead. For service at 600 volts or less (phase to phase) at a conductor temperature of 75 ºC maximum for polyethylene Insulation or 90 ºC maximum for crosslinked insulation.

    Construction
    Concentric strand or compressed 1350-H19 conductor, polyethylene or crosslinked polyethylene insulation, concentric strand AAC neutral messenger.

    Standards

    • B-230 Aluminum Wire 1350-H19 for Electrical Purposes.
    • B-231 Aluminum Conductors, Concentric-Lay-Stranded.
    • B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR).
    • B-399 Concentric-Lay-Stranded 6201-T81 Aluminum Alloy Conductors.
    • B-498 Zinc-Coated Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR).
    • Triplex Service Drop cable meets or exceeds all applicable requirements of ANSI/ICEA body S-76-474.

  • Triplex Service Drop<br>Aluminum Conductor

    Applications
    To supply power from the utility's lines to the consumer's weatherhead. For service at 600 volts or less (phase to phase) at a conductor temperature of 75 ºC maximum for polyethylene Insulation or 90 ºC maximum for crosslinked insulation.

    Construction
    Concentric strand or compressed 1350-H19 conductor, polyethylene or crosslinked polyethylene insulation, concentric strandACSR neutral messenger.

    Standards

    • B-230 Aluminum Wire 1350-H19 for Electrical Purposes.
    • B-231 Aluminum Conductors, Concentric-Lay-Stranded
    • B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR).
    • B-309 Concentric-Lay-Stranded 6201-T81 Aluminum Alloy Conductors.
    • B-498 Zinc-Coated Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR).
    • Triplex Service Drop cable meets or exceeds all applicable requirements of ANSI/ICEA body S-76-474.

  • Triplex Service Drop<br>Aluminum Conductor

    Applications
    To supply power from the utility's lines to the consumer's weatherhead. For service at 600 volts or less (phase to phase) at a conductor temperature of 75 ºC maximum for polyethylene Insulation or 90 ºC maximum for crosslinked insulation.

    Construction
    Concentric strand or compressed 1350-H19 conductor, polyethylene or crosslinked polyethylene insulation, concentric strand 6201 alloy neutral messenger.

    Standards

    • B-230 Aluminum Wire 1350-H19 for Electrical Purposes.
    • B-231 Aluminum Conductors, Concentric-Lay-Stranded.
    • B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR).
    • B-399 Concentric-Lay-Stranded 6201-T81 Aluminum Alloy Conductors.
    • B-498 Zinc-Coated Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR).
    • Triplex Service Drop cable meets or exceeds all applicable requirements of ANSI/ICEA body S-76-474