  • Single Conductor Type URD Cable<br>Aluminum Conductor

    Applications
    Directly buried or installed in ducts for 600 volt secondary distribution.

    Construction
    Concentric stranded or compressed 1350-H19 aluminum conductor, crosslinked polyethylene insulation.

    Standards
    Secondary URD single conductor 600V cable meets or exceeds the following ASTM specifications.

    • B-230 Aluminum Wire, 1350-H19 for Electrical Purposes.
    • B-231 Aluminum 1350 conductors, Concentric-Lay-Stranded.
    • B-786 "19 Wire combination unilay-stranded Aluminum Conductors for subsequent insulation".
    • B-901 "Compressed round stranded Aluminum Conductors using single input wire construction".
    • Secondary UD single conductor 600V cable meets or exceeds all applicable requirements of ICEA S-105-692.
    • "USE-2" per UL 854 available upon request.
    Options
    • Cable in Duct (CIC)
    • Abrasion Resistant
    Ampacity
    90ºC conductor temperature, 20ºC ambient, RHO factor 90, 100% load factor for three conductor triplexed, 3 phase operation. To determine correct ampacity by conductor size, please consult the National Electric Code, latest edition.

  • Single Conductor Type URD Cable<br>Aluminum Conductor

    Applications
    Directly buried or installed in ducts for 600 volt secondary distribution.

    Construction
    Concentric stranded or compressed (8176-H24) aluminum conductor, crosslinked polyethylene insulation.

    Standards
    Secondary URD single conductor 600V cable meets or exceeds the following ASTM specifications.

    • B-800 8000 Series Aluminum Alloy Wire for Electrical Purposes
    • B-801 Concentric-Lay-Stranded Conductors of 8000 Series Aluminum Alloy for Subsequent Covering or Insulation.
    • B-901 "Compressed round stranded Aluminum Conductors using single input wire construction".
    • Secondary UD triplex conductor 600V cable meets or exceeds all applicable requirements of ICEA S-105-692.
    • UL Standard 44 for Type RHH or RHW-2
    • UL standard 854 for Type USE-2.
    Options
    • Cable in Duct (CIC)
    • Abrasion Resistant
    Ampacity
    90ºC conductor temperature, 20ºC ambient, RHO factor 90, 100% load factor for three conductor triplexed, 3 phase operation. To determine correct ampacity by conductor size, please consult the National Electric Code, latest edition.