ISO 9001:2008ISO 9001
Certified
A POWERFUL SOLUTION
All Categories > Multiplex Cables (Overhead and Underground) > Aluminum Service Drop 600V > Quadruplex Service Drop Aluminum Conductor  
 

Quadruplex Service Drop Aluminum Conductor


Click on a Product to view details.

Quadruplex Service Drop Cable<br>Aluminum Conductor

Quadruplex Service Drop Aluminum Conductors - AAC Neutral-Messenger

(8)
Applications
Used to supply 3 phase power, usually from a pole- mounted transformer, to the user's service head where connection to the service entrance cable is made. To be used at voltages of 600 volts or less phase to phase and at conductor temperatures not to exceed 75 ºC for polyethylene insulated conductors or 90 ºC for crosslinked polyethylene (XLP) insulated conductors.

Construction
Conductors are concentrically stranded, compressed 1350-H19 aluminum. Insulated with either polyethylene or XLP crosslinked polyethylene. Neutral messengers are concentrically stranded AAC. One conductor is manufactured with an extruded ridge for phase identification.

...
Quadruplex Service Drop Cable<br>Aluminum Conductor

Quadruplex Service Drop Aluminum Conductors - ACSR Neutral-Messenger

(11)
Applications
Used to supply 3 phase power, usually from a pole- mounted transformer, to the user's service head where connection to the service entrance cable is made. To be used at voltages of 600 volts or less phase to phase and at conductor temperatures not to exceed 75 ºC for polyethylene insulated conductors or 90 ºC for crosslinked polyethylene (XLP) insulated conductors.

Construction
Conductors are concentrically stranded, compressed 1350-H19 aluminum. Insulated with either polyethylene or XLP crosslinked polyethylene. Neutral messengers are concentrically stranded ACSR. One conductor is manufactured with an extruded ridge for phase identification.

...
Quadruplex Service Drop Cable<br>Aluminum Conductor

Quadruplex Service Drop Aluminum Conductors AAAC 6201 Alloy Neutral-Messenger

(9)
Applications
Used to supply 3 phase power, usually from a pole- mounted transformer, to the user's service head where connection to the service entrance cable is made. To be used at voltages of 600 volts or less phase to phase and at conductor temperatures not to exceed 75 ºC for polyethylene insulated conductors or 90 ºC for crosslinked polyethylene (XLP) insulated conductors.

Construction
Conductors are concentrically stranded, compressed 1350-H19 aluminum. Insulated with either polyethylene or XLP crosslinked polyethylene. Neutral messengers are concentrically stranded 6201 alloy. One conductor is manufactured with an extruded ridge for phase identification.

Standards
  • B-230 Aluminum Wire, ...
Privacy     Site Map     Catalog IndexSite created by Thomas Web Solutions and Powered by Navigator Platform© 2021, American Wire Group