ISO 9001:2008ISO 9001
Certified
A POWERFUL SOLUTION
  • Duplex Service Drop<br>Aluminum Conductor

    Applications
    To supply 120 volt aerial service for temporary service at construction sites, outdoor or street lighting. For service at 600 volts or lower at a conductor temperature of 75 ºC maximum.

    Construction
    Concentric strand or compressed 1350-H19 conductor, polyethylene or crosslinked polyethylene insulation, concentric strand AAC neutral messenger.

    Standards

    • B-230 Aluminum Wire, 1350-H19 for Electrical Purposes.
    • B-231 Aluminum Conductors, Concentric-Lay-Stranded.
    • B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR).
    • B-399 Concentric-Lay_Stranded 6201-T81 Aluminum Alloy Conductors.
    • B498 Zinc-Coated Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR).
    • Duplex Service Drop cable meets or exceeds all applicable requirements of ANSI/ICEA S-76-474.

  • Duplex Service Drop<br>Aluminum Conductor

    Applications
    To supply 120 volt aerial service for temporary service at construction sites, outdoor or street lighting. For service at 600 volts or lower at a conductor temperature of 75 ºC maximum.

    Construction
    Concentric strand or compressed 1350-H19 conductor, polyethylene or crosslinked polyethylene insulation, concentric strand ACSR neutral messenger.

    Standards

    • B-230 Aluminum Wire, 1350-H19 for Electrical Purposes.
    • B-231 Aluminum Conductors, Concentric-Lay-Stranded.
    • B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR).
    • B-399 Concentric-Lay_Stranded 6201-T81 Aluminum Alloy Conductors.
    • B498 Zinc-Coated Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR).
    • Duplex Service Drop cable meets or exceeds all applicable requirements of ANSI/ICEA S-76-474.

  • Duplex Service Drop<br>Aluminum Conductor

    Applications
    To supply 120 volt aerial service for temporary service at construction sites, outdoor or street lighting. For service at 600 volts or lower at a conductor temperature of 75 ºC maximum.

    Construction
    Concentric strand or compressed 1350-H19 conductor, polyethylene or crosslinked polyethylene insulation, concentric strand 6201 alloy neutral messenger.

    Standards

    • B-230 Aluminum Wire, 1350-H19 for Electrical Purposes.
    • B-231 Aluminum Conductors, Concentric-Lay-Stranded.
    • B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR).
    • B-399 Concentric-Lay_Stranded 6201-T81 Aluminum Alloy Conductors.
    • B498 Zinc-Coated Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR).
    • Duplex Service Drop cable meets or exceeds all applicable requirements of ANSI/ICEA S-76-474.