All Categories > Multiplex Cables (Overhead and Underground) > Aluminum Secondary URD 600V > Duplex Conductor Type URD Cable - Aluminum Conductor  
 

Duplex Conductor Type URD Cable - Aluminum Conductor


Click on a Product to view details.

Duplex Conductor Type URD Cable<br>Aluminum Conductor

Duplex Conductor 600V Secondary Type URD Cable - Aluminum Conductor

(4)
Applications
Directly buried or installed in ducts for 600 volt secondary distribution.

Construction
Concentric stranded or compressed 1350-H19 aluminum conductor, cross-linked polyethylene insulation. Insulated conductors surface printed, neutral triple yellow striped. Black neutrals may be specified if desired.

Standards
Secondary URD duplex conductor 600V cable meets or exceeds the following ASTM specifications.
  • B-230 Aluminum Wire, 1350-H19 for Electrical Purposes.
  • B-231 Aluminum 1350 conductors, Concentric-Lay-Stranded.
  • B-786 ""19 Wire combination unilay-stranded Aluminum Conductors for subsequent insulation"".
  • B-901 ""Compressed round ...
Duplex Conductor Type URD Cable<br>Aluminum Conductor

Duplex Conductor 600V Secondary Type URD Cable - (8000) RHH/RHW-2 USE-2 - Aluminum Conductor

(4)
Applications
Directly buried or installed in ducts for 600 volt secondary distribution.

Construction
Concentric stranded or compressed 8000 (8176-H24) aluminum conductor, crosslinked polyethylene insulation. Insulated conductors surface printed, neutral triple yellow striped. Black neutrals may be specified if desired.

Standards
Secondary URD duplex conductor 600V cable meets or exceeds the following ASTM specifications.
  • B-800 8000 Series Aluminum Alloy Wire for Electrical Purposes
  • B-801 Concentric-Lay-Stranded Conductors of 8000 Series Aluminum Alloy for Subsequent Covering or Insulation.
  • B-901 "Compressed round stranded Aluminum Conductors using ...
Duplex Conductor Type URD Cable<br>Aluminum Conductor

Duplex Conductor 600V Secondary Type URD Cable - Aluminum Conductor Ruggedized

(2)

Application
Used for secondary distribution and underground service at 600 volts or less, either direct burial or in ducts. Especially suited for applications requiring superior resistance to mechanical damage. Rated 90°C continuous operation, 130°C emergency overload and short circuit 250°C.

Construction
Conductors are stranded, compressed 1350-H16/H26 aluminum, insulated with a cross-linked polyethylene meeting the requirements of ANSI/ICEA S-81-570. Neutrals are triple yellow extruded stripe and have sequential footage markers. Conductors are durably surface printed for identification.

Standards
Ruggedized duplex 600 volt secondary UD cable meets or exceeds the following ...